Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
China Medical Equipment ; (12): 18-21, 2017.
Artículo en Chino | WPRIM | ID: wpr-612788

RESUMEN

Objective:To collect and analyze the quality control data of ventilator, so as to apply these statistical data to guide the maintenance and management of ventilator.Methods: The displayed value and monitoring value of the tidal volume, respiratory frequency, inspiratory oxygen concentration, inspiratory pressure level and positive end expira tory pressure (PEEP) under different setting of 50 using ventilators in hospital were collected by using PF-300 gas analyzer, and then each parameter was analyzed as classification.Results: The total quality rate of ventilators was 80%, the ranking of quality rate as different brand was: brand B>brand A>brand C, and it was as different department: department 5>department 4=department 3>department1>department2, and the quality rates of less than 3 years and more than 3 years were 87% and 77%, respectively, as service life of ventilator. And the ranking of quality rates as parameters of ventilator was: PEEP=respiratory frequency >peak pressure>tidal volume >oxygen concentration. It was as accuracy of monitoring: brand A>brand C>brand B. It was as stability of monitoring: brand A>brand B=brand C. On the other hand, it was as the accuracy of displayed value: brand A>brand B>brand C, while it was as the stability of displayed value: brand A>brand C>brand B.Conclusion: The analysis of quality control data only suits to the ventilator which is used in our hospital. The engineer can targeted to strengthen the ventilator maintenance work and improve the quality and safety of equipment, so as to give the better service for patients according to quality control data of using ventilators in hospital.

2.
China Medical Equipment ; (12): 8-11, 2017.
Artículo en Chino | WPRIM | ID: wpr-508312

RESUMEN

Objective:To develop a reflection-type blood oxygen monitor module can transmit message by a new wireless sensor and be used as a terminal monitoring node in wearable devices.Methods: The blood oxygen algorithm is mathematically analyzed by Lambert Beer law; the terminal schematic diagram of hardware, drive circuit, transimpedance amplifier and filter circuit of sensor NJL5501R are analyzed and designed to use in the module; the software process and algorithm implementation is described by special software; the Fluke INDEX2XLF is used to simulate blood oxygen saturation and determine the Q value and then to establish relevant relationship between blood oxygen saturation and Q value.Results: The module can collect blood oxygen data and transmit them by wireless method. And detection result error was less than 2% when this module was compared with the MINDRAY IPM10.Conclusion: The module achieves the expected effect although it still need be improved in some aspects, such as anti movement interference, miniaturization design and low power consumption.

3.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 411-414,427, 2015.
Artículo en Chino | WPRIM | ID: wpr-601776

RESUMEN

Objective Anti-calcification and surface modification of the transcatheter heart valve is the priority research area and development direction of bioprosthesis heart valve.In present study,the Arginine-Glycine-Aspartic acid(RGD) coating technology and anti-calcification with epoxy chloropropane(EC) treatment were applied to investigate surface modification property of the transcatheter heart valve compared to the traditional anti-calcification method with glutaraldehyde (GA) treatment to demonstrate the improvement of structure and surface biological properties of the transcatheter heart valve.Methods Morphological characteristics of mesenchymal stem cells(MSCs) seeded on the transcatheter heart valve with the various anticalcification treatments were observed by scanning electron microscopy and the apoptosis rates of MSCs seeded on the transcatheter heart valve with the various anti-calcification interventions were studied by TUNEL staining.The cell adhesion and expression of the cytoskeletal protein,Vinment of MSCs treated as described were analyzed by cell-counting method and fluorescence immunohistochemical method respectively.Results The apoptosis rate of MSCs was markedly decreased while the expression of vinment and the cell adhesion strength of MSCs were elevated in the groups of GA-EC and RGD-EC treatments.The biological indices of RGD-EC group has significant difference(P < 0.05) compared with GA group.Conclusion Biological properties of the surface of transcatheter heart valve can be remarkably improved by GA-EC and RGD-EC anti-calcification treatments.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA