Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Forensic Medicine ; (6): 505-510, 2021.
Artículo en Chino | WPRIM | ID: wpr-985240

RESUMEN

Objective To establish a method that combines a series of techniques including Fourier transform infrared spectrum (FTIR), gas chromatography-mass spectrometry (GC-MS), high resolution mass spectrometry and nuclear magnetic resonance spectroscopy (NMR) for identification of unknown substances. Methods The unknown samples (off-white powder and yellow crystal) seized in the actual cases were detected by FTIR, GC-MS (methanol as solvent), high resolution mass spectrometry (methanol as solvent) and NMR (deuterated methanol as solvent). Results The mass spectrum characteristic ions m/z of the main components in the samples measured by GC-MS were 219 (base peak), 363, 307, 304, 275, 145, 131 and 213 (base peak), 357, 301, 298, 269, 185, 171, 145 and 131, respectively. The accurate mass numbers [M+H]+ measured by high resolution mass spectrometry were 364.203 61 and 358.212 34, respectively. The unknown samples were identified as synthetic cannabinoid new psychoactive substances 4F-MDMB-BUTINACA and MDMB-4en-PINACA after data consultation and database retrieval and comparison, combined with infrared analysis and mass spectrometry data analysis, and their structures were confirmed by 1H-NMR. Conclusion The established multi-technology joint identification method can be used to identify 4F-MDMB-BUTINACA and MDMB-4en-PINACA in unknown samples. This method is fast, convenient, accurate, reliable and practical, and can provide reference for the identification of cases involving such substances in the future.


Asunto(s)
Cannabinoides , Cromatografía de Gases y Espectrometría de Masas , Drogas Ilícitas , Espectroscopía de Resonancia Magnética , Espectrometría de Masas
2.
Journal of Forensic Medicine ; (6): 682-686, 2019.
Artículo en Inglés | WPRIM | ID: wpr-985063

RESUMEN

Objective To establish a method to identify unknown samples based on combined use of gas chromatography-mass spectrometry (GC-MS), high resolution mass spectrometry (HRMS) and nuclear magnetic resonance spectrum (NMR) technique. Methods The unknown samples were dissolved in methanol solution containing internal standard SKF525A and detected by GC-MS and HRMS. The mixed samples were separated and purified by silica gel column chromatography, and then dissolved in methanol-d4 solution for structural analysis of 1H nuclear magnetic resonance spectroscopy (1H NMR). Results The characteristic fragment ions (m/z) were 86.1 (base peak), 71.2, 121.1, and 149.0, and the accurate mass number of molecular ion peak was measured by HRMS to be 236.128 89. By combined use of data analysis and database comparison, a new psychoactive substance of the cathinone class, Dibutylone, was detected in the sample, and the sample also contained a small amount of caffeine. The sample was purified, then identified using 1H NMR, and was further confirmed to be Dibutylone. In addition, the GC-MS retention time and characteristic fragment ions of the main components of the sample were consistent with those of Dibutylone reference material. Conclusion The method established in this study can be used for the identification of Dibutylone in mixed samples.


Asunto(s)
Cromatografía Liquida , Cromatografía de Gases y Espectrometría de Masas , Espectroscopía de Resonancia Magnética , Espectrometría de Masas , N-Metil-3,4-metilenodioxianfetamina/aislamiento & purificación , Psicotrópicos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA