Journal of Cerebrovascular and Endovascular Neurosurgery ; : 306-314, 2016.
Artículo en Inglés | WPRIM | ID: wpr-35418

RESUMEN

We report the case of a recurrent carotid cavernous fistula (CCF) originating from a giant cerebral aneurysm (GCA) after placement of a covered stent. A 47-year-old woman presented with sudden onset of severe headache, and left-sided exophthalmos and ptosis. Cerebral angiography revealed a CCF caused by rupture of a GCA in the cavernous segment of the left internal carotid artery. Two covered stents were placed at the neck of the aneurysm. The neurological symptoms improved at first, but were aggravated in the 6 months following the treatment. Contrast agent endoleak was seen in the distal area of the stent. Even though additional treatments were attempted via an endovascular approach, the CCF could not be cured. However, after trapping the aneurysm using coils and performing superficial temporal artery-middle cerebral artery bypass, the neurological symptoms improved. In cases of recurrent CCF originating from a GCA after placement of a covered stent, it is possible to treat the CCF by endovascular trapping and surgical bypass.


Asunto(s)
Femenino , Humanos , Persona de Mediana Edad , Aneurisma , Arteria Carótida Interna , Fístula del Seno Cavernoso de la Carótida , Angiografía Cerebral , Arterias Cerebrales , Endofuga , Exoftalmia , Fístula , Cefalea , Aneurisma Intracraneal , Cuello , Rotura , Stents