Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. bras. cardiol. invasiva ; 22(3): 252-257, Jul-Sep/2014. tab, graf
Artículo en Portugués | LILACS-Express | LILACS, SES-SP | ID: lil-732777

RESUMEN

Introdução: O volume de hiperplasia intimal correlaciona-se com a injúria arterial após implante de stents não farmacológicos. No entanto, pouco se sabe a respeito do impacto da injúria arterial na resposta inflamatória/proliferativa com os stents farmacológicos. Investigamos o impacto da injúria arterial, avaliada pela relação balão/artéria, no volume de obstrução neontimal, avaliado pelo ultrassom intracoronário 12 meses após o implante de stents farmacológicos com eluição de zotarolimus. Métodos: A relação balão/artéria foi definida como a razão do diâmetro máximo do balão, obtido no implante ou na pós-dilatação, e o diâmetro de referência do vaso pré-procedimento. Os pacientes foram categorizados em dois grupos: relação balão/artéria alta (≥ 1,15) e relação balão/artéria baixa (< 1,15). Resultados: Foram incluídos 86 pacientes, nos grupos relação balão/artéria baixa (n = 47/48 lesões) ou relação balão/artéria alta (n = 39/48 lesões). As características clínicas, angiográficas e do procedimento não diferiram entre os grupos, à exceção do diâmetro de referência dos vasos (2,73 ± 0,45 mm vs. 2,97 ± 0,40 mm; p = 0,01). Aos 12 meses, observou-se semelhante perda tardia intra-stent (0,59 ± 0,32 mm vs. 0,62 ± ...


Background: Intimal hyperplasia volume is correlated to arterial injury after bare-metal stenting. However, little is known about the impact of arterial injury on the inflammatory/ proliferative response with drug-eluting stents. We investigated the impact of arterial injury, evaluated by the balloon/artery ratio, on neointimal hyperplasia volume obstruction, evaluated by intravascular ultrasound, 12 months after zotarolimus-eluting stent implantation. Methods: Balloon/ artery ratio was defined as the ratio of the maximum balloon diameter, using the maximal implantation or post-dilatation pressure, and the reference diameter of the vessel obtained before the procedure. Patients were divided into two groups: high balloon/artery ratio (≥ 1.15) and low balloon/artery ratio (< 1.15). Results: A total of 86 patients were included in the low balloon/artery ratio group (n = 47/48 lesions) or high balloon/artery ratio (n = 39/48 lesions). The clinical, angiographic and procedurerelated characteristics were not different between groups, except for the vessel reference diameter (2.73 ± 0.45 mm vs. 2.97 ± 0.40 mm; p = 0.01). At 12 months, similar in-stent late loss was observed (0.59 ± 0.32 mm vs. 0.62 ± 0.42 mm; p = 0.92), as well as binary restenosis (4.2% in both cohorts; p > 0.99). Instent neointimal hyperplasia volume obstruction (15.2 ± 14.3% vs. 12.5 ± 10.1%; p = 0.62) showed no difference between groups. No correlation was observed between balloon/artery ratio ...

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA