Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Indian J Med Sci ; 2000 Feb; 54(2): 43-51
Artículo en Inglés | IMSEAR | ID: sea-68901

RESUMEN

Between 1993-96, blood donated by 12,235 replacement blood donors was screened by various Enzyme Linked Immunosorbent Assays for detecting antibodies to Human Immunodeficiency Viruses types 1 and 2 according to the guidelines specified by Indian--Food and Drug Administration. 222 replacement blood donors (1.81%) were found to be seropositive for antibodies to Human Immunodeficiency Virus types 1 and 2. Furthermore, the ImmunoComb II HIV 1 & 2 BiSpot rapid sandwich ELISA in a comb format was used for differentially identifying HIV-1 and/or HIV-2 infection among these blood donors in Mumbai. Our data indicates that there is a low seroprevalence of HIV-1-2 infection among replacement blood donors in Mumbai (Bombay). Among them, while HIV-1 is still the predominant virus, dual HIV-1-2 and HIV-2 only infections are steadily increasing.


Asunto(s)
Serodiagnóstico del SIDA , Donantes de Sangre , Ensayo de Inmunoadsorción Enzimática , Femenino , Anticuerpos Anti-VIH/sangre , Seropositividad para VIH/epidemiología , VIH-1/aislamiento & purificación , VIH-2/aislamiento & purificación , Humanos , India/epidemiología , Masculino
2.
Indian J Med Sci ; 1999 Aug; 53(8): 343-8
Artículo en Inglés | IMSEAR | ID: sea-68109

RESUMEN

A study was carried out to find out the humoral and cell mediated immunity levels in patients with TBM and healthy controls. For humoral immunity, the amounts of immunoglobulins--IgG, IgM and IgA were quantitated by SRID method. For cell mediated immunity, percentages of total T cells, Th cells and Ts cells and the ratio of Th:Ts cells was studied. Hypergammaglobulinemia of all three immunoglobulins was observed together with a decrease in the total T cells and Th cells, and a lower Th:Ts cell ratio indicating a deficiency or a defect in the immune system of patients infected with TBM.


Asunto(s)
Formación de Anticuerpos/inmunología , Niño , Preescolar , Femenino , Humanos , Inmunidad Celular/inmunología , Inmunoglobulina G/sangre , India , Masculino , Sensibilidad y Especificidad , Tasa de Supervivencia
3.
Artículo en Inglés | IMSEAR | ID: sea-118458

RESUMEN

BACKGROUND: Saliva has been recommended as an alternative non-invasive specimen for detection of antibodies to human immunodeficiency virus (HIV) because of the inherent disadvantages of using serum for such testing. METHODS: In a double-blind study, paired serum and saliva specimens were collected from 100 known HIV antibody seropositive and 100 seronegative individuals. The serum was tested in the conventional way while saliva was tested after modifying the routinely used serum enzyme-linked immunosorbent assay so as to detect antibodies to HIV from saliva. RESULTS: The sensitivity of saliva for HIV antibody detection using the modified test protocol was found to be 95% by GENELAVIA MIXT ELISA and 97% by DETECT-HIV ELISA, while the specificity for both was 100%. Identical results were obtained even after 7 months of storage of the saliva at 4 degrees C without any preservatives. CONCLUSION: Saliva is a safe and cost-effective alternative to serum for HIV antibody detection for most surveillance purposes but not for diagnostic purposes.


Asunto(s)
Anticuerpos Antivirales/aislamiento & purificación , Ensayo de Inmunoadsorción Enzimática , VIH/inmunología , Infecciones por VIH/diagnóstico , Humanos , Sensibilidad y Especificidad
5.
Indian J Public Health ; 1999 Apr-Jun; 43(2): 85-6
Artículo en Inglés | IMSEAR | ID: sea-109823

RESUMEN

Between 1993-96, a serological study was carried out for differentially identifying HIV-1 and HIV-2 infections among the high risk group persons attending the various outdoor patient departments of BYL Nair Municipal Hospital, Mumbai. This study indicates that although HIV-1 is still the predominant virus among the high risk HIV infected persons in Mumbai, dual HIV-1-2 infections are increasing especially among promiscuous heterosexuals and female commercial sex workers. Increases in HIV-2 infections were observed later than dual HIV-1-2 infections, indicating that it is the HIV-1 infected individuals who through continued high risk behavior got infected by HIV-2.


Asunto(s)
Serodiagnóstico del SIDA , Western Blotting , Ensayo de Inmunoadsorción Enzimática , Anticuerpos Anti-VIH/sangre , Infecciones por VIH/diagnóstico , VIH-1/inmunología , VIH-2/inmunología , Humanos , India/epidemiología , Servicio Ambulatorio en Hospital/estadística & datos numéricos , Trabajo Sexual
6.
Indian Pediatr ; 1999 Apr; 36(4): 362-7
Artículo en Inglés | IMSEAR | ID: sea-11846

RESUMEN

OBJECTIVE: To compare the cellular and humoral factors in colostrum from HIV infected and uninfected lactating mothers. DESIGN: Cross sectional study. SETTING: Maternity Ward. METHODS: Colostrum was collected from 130 mothers (62 HIV seropositives and 68 HIV seronegatives). These colostrum samples were tested for total cell count, cell viability, differential count, phagocytic activity of macrophages, 'T' cell counts, IgA, IgM and IgG levels. RESULTS: There was a statistically significant decrease in the phagocytosis and 'T' cell number (p <0.001) and in the IgA and IgG levels (p<0. 05) in the colostrum obtained from HIV seropositive mothers as compared to HIV seronegative ones. CONCLUSION: Some of the cellular and humoral factors are reduced in colostrum samples obtained from HIV seropositives as compared to normals.


Asunto(s)
Adolescente , Adulto , Lactancia Materna , Estudios de Casos y Controles , Calostro/química , Estudios Transversales , Femenino , Anticuerpos Anti-VIH/análisis , Infecciones por VIH/inmunología , Seronegatividad para VIH/inmunología , Humanos , Inmunoglobulina A/análisis , Inmunoglobulina G/análisis , Inmunoglobulina M/análisis , Recuento de Linfocitos , Macrófagos/inmunología , Fagocitosis/inmunología , Trastornos Puerperales/inmunología , Linfocitos T
7.
Indian J Med Sci ; 1998 Dec; 52(12): 548-52
Artículo en Inglés | IMSEAR | ID: sea-66289

RESUMEN

Between 1993 and 1996, we carried out a serological screening for differentially identifying HIV-1 and HIV-2 infections among the high risk group persons admitted in the various wards of BYL Nair Hospital, Mumbai, using the ImmunoComb kit. This study indicates that although HIV-1 is the predominant virus prevalent in Mumbai, dual HIV-1-2 and HIV-2 infections are gradually increasing.


Asunto(s)
Adulto , Donantes de Sangre/estadística & datos numéricos , Infecciones por VIH/epidemiología , Seroprevalencia de VIH/tendencias , VIH-1/aislamiento & purificación , VIH-2/aislamiento & purificación , Humanos , India/epidemiología , Persona de Mediana Edad , Estudios Seroepidemiológicos
8.
Indian J Med Sci ; 1998 Nov; 52(11): 479-84
Artículo en Inglés | IMSEAR | ID: sea-69133

RESUMEN

Between 1993 and 1996, we carried out a serological screening for differentially identifying HIV-1 and HIV-2 infections among the high risk group persons admitted in the various wards of BYL Nair Hospital, Mumbai, using the ImmunoComb kit. This study indicates that although HIV-1 is the predominant virus prevalent in Mumbai, dual HIV-1-2 and HIV-2 infections are gradually increasing.


Asunto(s)
Ensayo de Inmunoadsorción Enzimática , Femenino , Infecciones por VIH/sangre , VIH-1 , VIH-2 , Humanos , India/epidemiología , Masculino , Prevalencia , Factores de Riesgo , Estudios Seroepidemiológicos
9.
Artículo en Inglés | IMSEAR | ID: sea-119857

RESUMEN

BACKGROUND. Patients with sexually transmitted diseases form a particularly vulnerable group for infection with the human immunodeficiency virus (HIV-1), and serological surveillance is a sensitive tool for assessing the prevalence of this disease. METHODS. We carried out a serological survey for the detection of antibody to HIV-1 among persons belonging to various high-risk groups in Bombay from 1987 to 1989. Among these were 599 patients with various sexually transmitted diseases. RESULTS. Thirty-nine patients (5.2%) were found to be HIV-1 antibody seropositive by the ELISA and Western blot tests. An increase in HIV-1 antibody seropositivity among both the male and female patients with sexually transmitted diseases was detected from 1987 to 1989 and seropositivity was maximally associated with condylomata acuminata, genital herpes and chancroid. CONCLUSION. HIV-1 is established in this sentinel population and needs to be controlled vigorously.


Asunto(s)
Serodiagnóstico del SIDA , Síndrome de Inmunodeficiencia Adquirida/complicaciones , Western Blotting , Ensayo de Inmunoadsorción Enzimática , Femenino , Seropositividad para VIH/epidemiología , VIH-1 , Humanos , India/epidemiología , Masculino , Prevalencia , Encuestas y Cuestionarios , Factores de Riesgo , Enfermedades de Transmisión Sexual/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA