Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Int. braz. j. urol ; 45(5): 932-940, Sept.-Dec. 2019. tab
Artículo en Inglés | LILACS | ID: biblio-1040076

RESUMEN

ABSTRACT Purpose We investigated the association between preoperative proteinuria and early postoperative renal function after robotic partial nephrectomy (RPN). Patients and Methods We retrospectively reviewed 1121 consecutive RPN cases at a single academic center from 2006 to 2016. Patients without pre-existing CKD (eGFR≥60 mL/min/1.73m2) who had a urinalysis within 1-month prior to RPN were included. The cohort was categorized by the presence or absence of preoperative proteinuria (trace or greater (≥1+) urine dipstick), and groups were compared in terms of clinical and functional outcomes. The incidence of acute kidney injury (AKI) was assessed using RIFLE criteria. Univariate and multivariable models were used to identify factors associated with postoperative AKI. Results Of 947 patients, 97 (10.5%) had preoperative proteinuria. Characteristics associated with preoperative proteinuria included non-white race (p<0.01), preoperative diabetes (p<0.01) and hypertension (HTN) (p<0.01), higher ASA (p<0.01), higher BMI (p<0.01), and higher Charlson score (p<0.01). The incidence of AKI was higher in patients with preoperative proteinuria (10.3% vs. 4.6%, p=0.01). The median eGFR preservation measured within one month after surgery was lower (83.6% vs. 91%, p=0.04) in those with proteinuria; however, there were no significant differences by 3 months after surgery or last follow-up visit. Independent predictors of AKI were high BMI (p<0.01), longer ischemia time (p<0.01), and preoperative proteinuria (p=0.04). Conclusion Preoperative proteinuria by urine dipstick is an independent predictor of postoperative AKI after RPN. This test may be used to identify patients, especially those without overt CKD, who are at increased risk for developing AKI after RPN.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Anciano , Complicaciones Posoperatorias/etiología , Proteinuria/complicaciones , Periodo Preoperatorio , Lesión Renal Aguda/etiología , Nefrectomía/efectos adversos , Valores de Referencia , Modelos Logísticos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Estadísticas no Paramétricas , Medición de Riesgo , Lesión Renal Aguda/fisiopatología , Tasa de Filtración Glomerular/fisiología , Neoplasias Renales/cirugía , Persona de Mediana Edad , Nefrectomía/métodos
3.
Int. braz. j. urol ; 40(6): 763-771, Nov-Dec/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-735990

RESUMEN

Purpose To investigate risk factors for urine leak in patients undergoing minimally invasive partial nephrectomy (MIPN) and to determine the role of intraoperative ureteral catheterization in preventing this postoperative complication. Materials and Methods MIPN procedures done from September 1999 to July 2012 at our Center were reviewed from our IRB-approved database. Patient and tumor characteristics, operative techniques and outcomes were analyzed. Patients with evidence of urine leak were identified. Outcomes were compared between patients with preoperative ureteral catheterization (C-group) and those without (NC-group). Univariable and multivariable analyses were performed to identify factors predicting postoperative urine leak. Results A total of 1,019 cases were included (452 robotic partial nephrectomy cases and 567 laparoscopic partial nephrectomy cases). Five hundred twenty eight patients (51.8%) were in the C-group, whereas 491 of them (48.2%) in the NC-group. Urine leak occurred in 31(3%) cases, 4.6% in the C-group and 1.4% in the NC-group (p<0.001). Tumors in NC-group had significantly higher RENAL score, shorter operative and warm ischemic times. On multivariable analysis, tumor proximity to collecting system (OR=9.2; p<0.01), surgeon’s early operative experience (OR=7.8; p<0.01) and preoperative moderate to severe CKD (OR=3.1; p<0.01) significantly increased the odds of the occurrence of a postoperative urine leak. Conclusion Clinically significant urine leak after MIPN in a high volume institution setting is uncommon. This event is more likely to occur in cases of renal masses that are close to the collecting system, in patients with preoperative CKD and when operating surgeon is still in the learning curve for the procedure. Our findings suggest that routine intraoperative ureteral catheterization during MIPN does not reduce the probability of postoperative urine leak. In addition, it adds to the overall ...


Asunto(s)
Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nefrectomía/efectos adversos , Cateterismo Urinario/métodos , Incontinencia Urinaria/etiología , Incontinencia Urinaria/prevención & control , Tasa de Filtración Glomerular , Cuidados Intraoperatorios , Análisis Multivariante , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Nefrectomía/métodos , Tempo Operativo , Reproducibilidad de los Resultados , Factores de Riesgo , Insuficiencia Renal Crónica/cirugía , Índice de Severidad de la Enfermedad , Estadísticas no Paramétricas , Factores de Tiempo , Resultado del Tratamiento
4.
Int. braz. j. urol ; 40(4): 578-579, Jul-Aug/2014.
Artículo en Inglés | LILACS | ID: lil-723956

RESUMEN

Introduction A duplicated renal collecting system is a relatively common congenital anomaly rarely presenting in adults. Aim In this video we demonstrate our step-by-step technique of Robotic heminephrectomy in a patient with non-functioning upper pole moiety. Materials and Methods Following cystoscopy and ureteral catheter insertion the patient was placed in 600 modified flank position with the ipsilateral arm positioned at the side of the patient. A straight-line, three arm robotic port configuration was employed. The robot was docked at a 90-degree angle, perpendicular to the patient. Following mobilization the colon and identifying both ureters of the duplicated system, the ureters were followed cephalically toward, hilar vessels where the hilar anatomy was identified. The nonfunctioning pole vasculature was ligated using hem-o-lok clips. The ureter was sharply divided and the proximal ureteral stump was passed posterior the renal hilum. Ureteral stump was used as for retraction and heminephrectomy is completed along the line demarcating the upper and lower pole moieties. Renorrhaphy was performed using 0-Vicryl suture with a CT-1 needle. The nonfunctioning pole ureter was then dissected caudally toward the bladder hiatus, ligated using clips, and transected. Results The operating time was 240 minutes and blood loss was 100 cc. There was no complication post-operatively. Conclusions Wrist articulation and degree of freedom offered by robotic platform facilitates successful performance of minimally invasive heminephrectomy in the setting of an atrophic and symptomatic renal segment. .


Asunto(s)
Femenino , Humanos , Adulto Joven , Túbulos Renales Colectores/anomalías , Túbulos Renales Colectores/cirugía , Nefrectomía/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Uréter/cirugía , Tempo Operativo , Reproducibilidad de los Resultados , Resultado del Tratamiento
5.
Int. braz. j. urol ; 33(6): 803-809, Nov.-Dec. 2007. ilus
Artículo en Inglés | LILACS | ID: lil-476644

RESUMEN

Robotic assisted radical prostatectomy (RARP) is gaining acceptance and popularity among urologists all over the world. Early oncologic and functional results are encouraging. In this manuscript, we describe in detail both approaches for RARP and show the results of the robotic surgery program with over 300 RARP performed at our institution.


Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Laparoscopía/métodos , Prostatectomía/métodos , Neoplasias de la Próstata/cirugía , Robótica/métodos , Estudios Prospectivos , Prostatectomía/instrumentación , Robótica/instrumentación , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA