RESUMEN
Objective This study was to evaluate the safety of 640 corneal donors by analysing the serological testing results.Methods We retrospectively analyzed the serological testing results from Changsha Aier Eye Bank and Chengdu Kangqiao Aier Eye Bank from January 2011 to December 2015,hepatitis B virus surface antigen (HBsAg),hepatitis C virus (HCV),treponema pallidum (TP) and human immunodeficiency virus (HIV) were detected by colloidal gold or enzyme-linked immunosorbent assay (ELISA).Results There were 83 out of 640 serum samples showed positive immuno-reaction assayed markers,the positive rate was 12.97%,including HBsAg(n=60,9.38%),HCV(n=3,0.47%),TP(n=11,1.72%) and HIV(n=2,0.31%).Moreover,3 corneal donors were both positive against HBsAg and HCV,2 donors positive against HCV and TP,1 donor positive against HBsAg and HIV,1 donor positive against HBsAg and TP.Conclusions There is a high proportion of positive results of blood-borne diseases in cornea donors,which is a potential threat to corneal receptors and eye bank workers.Therefore,it is very important to detect serological test strictly for corneal donors.
RESUMEN
Objective To study port-externalized tissue expansion technique and to provide a safe,simple and effective skin tissue expansion for extensive skin lesion reconstruction.Methods A lot of 247 patients with extensive skin lesion were chosen for the study.400-1000 ml tissue expanders were used for overexpansion and repeated expansion.Expanders were inserted into subcutaneous pockets through mini-invasive incisions and intermittent injection was carried out 4 days after first stage operation.After expansion finished,expanded skin flaps were transplanted for skin lesion reconstruction.During inflation period,complications and expander failures were observed.Results In 741 expanders of 247 patients,complication rate was 16.5 % with total 122 cases of complications.Expansion success rate was 98.9 % with 8 expander failures.Expanders were inflated successfully between 64-113 days,with average 92.7 days.The inflated saline volume was 2.38 times of marked expander capacity.In this group of 733 expanded skin flaps,721 flaps were well survived with 98.4% success rate.276 expanded flaps of 116 patients were followed up for one to five years post-operation.The width of incision scar was between 0.3-1.2 mm.Conclusions The port-externalized overexpansion with giant expanders is a safe,simple and feasible technique,which is worthy of further clinical application.
RESUMEN
In-vitro assay methods were established to evaluate transactivation and binding activity of compounds on peroxisome proliferator-activated receptor y (PPARγ). Firstly, plasmids were constructed for transactivation assay of PPARγ response element (PPRE) triggered reporter gene expression, and for cell-based binding activity assay of the chimeric receptor, which was fused with PPARγ ligand binding domain (LBD) and yeast transcriptional activator Gal4. Secondly, by using PPARy competitive binding assay based on time resolved-fluorescence resonance energy transfer (TR-FRET), affinities of compounds and drugs to PPARγ were evaluated. In application of these above methods, the PPARγ activating potency and characteristics of different compounds were evaluated, and a novel benzeneselfonamide derivative, ZLJ01, was found to have comparable binding activity and affinity with the well-known PPARy agonist, but lack of PPRE mediated transactivation activity. In preliminary study on in-vitro hypoglycemic activity, ZLJ1 was found to promote insulin-stimulated glucose uptake by liver cells. Therefore, we believe that combining transactivation and binding activity as well as affinity evaluation, the system could be used to screen non-agonist PPARγ ligand as anovel PPARγ modulator
RESUMEN
Objective To investigate the difference of IOL Master and A-ultrasound combined with corneal topography meas-urement in intraocular lens ( IOL) power calculation .Methods A total of 84 eyes of 60 cataract patients received phacoemulsification and intraocular lens implantation surgery were selected in Xiangya Hospital from March 2010 to September 2011.There were 57 eyes of 42 age-related cataract patients and 27 eyes of 18 complicated cataract patients .The patients were divided into IOL Master group and A ultrasound combined with corneal topography measurement group .Before surgery , in IOL Master group , axial length ( AL) and corneal curvature were measured with IOL Master , IOL power was calculated according to the Haigis , SRK/T formula and so on.At the same time the axial length ( AL) and corneal curvature were measured with A ultrasound combined with corneal topography respectively and IOL power was calculated by SRK/Ⅱ formula.In A ultrasound combined with corneal topography measurement group , axial length ( AL) and corneal curvature were measured with A ultrasound combined with corneal topography respectively , IOL power was calculat-ed according to the SRK/Ⅱformula.3 months postoperatively , all the patients were conducted refractive outcome and calculating mean absolute refractive error(MAE).Finally the data were analysed.Results ⑴In IOL Master group, before operation there was no sig-nificant difference in mean axial length between IOL Master and A-ultrasound measurement ( P >0.05 ) , while in the patients with AL>26 mm the axial length was (28.53 ±0.57)mm and (29.42 ±0.64)mm using IOL Master and A-ultrasound measurement respec-tively ( P <0.05).The mean corneal curvature was (42.12 ±0.31)D and (43.09 ±0.27)D using IOL Master and corneal topogra-phy measurement respectively ( P <0.01).The mean IOL power were (17.06 ±0.48)D and (16.37 ±0.56)D in IOL Master group and A ultrasound combined with corneal topography measurement group respectively ( P <0.05 ) .⑵3 months postoperatively , the MAE was (0.07 ±1.05)D and (0.16 ±0.81)D in IOL Master group and A-ultrasound combined with corneal topography measure-ment group( P <0.05) respectively.Conclusions In cataract patients with normal axial length , IOL Master and A-ultrasound com-bined with corneal topography have high consistency for axial length measurement and IOL power calculation .But in cataract patients with high myopia , IOL Master is more accurate for axial length measurement and IOL power calculation compared to A -ultrasound com-bined with corneal topography .
RESUMEN
Objective To investigate a new technique for small wound repairs on the faces.Methods 71 skin lesions of 42 patients were selected in the study and removed with ring-cutting drills.The new formed small wounds were treated with nature repair technique under the help of bFGF and hyaluronic acid (HA).The bFGF and HA were applied on the wounds 3 times a day until the wounds were healed completely.The early and long-term healing effects were estimated.Results The wounds were all cured with very small scars.The wounds were healed within 15 days for the size of 7 mm × 7 mmand25 days for the size of 15 mm × 15 mm.63 lesion spots from 35 patients were followed up 12 months later.Compared with original skin lesion,the small scar contracted about 50%in size with flat appearance and similar skin color.Conclusions The tissue regeneration and nature repair technique is an ideal surgical procedure for small wounds on the faces with good appearance in quality and aesthetics.
RESUMEN
Objective To develop a technique of aesthetic repair procedures for the skin and soft tissue defect after injury.Methods Nineteen cases of patients with skin and soft tissue defects after injury were chosen in this study,in which there were 19 wounds involved.Thirty-seven expanders were inserted into the subcutaneous pockets beside the wounds in the right time and were inflated by a fast expansion model (one time every two days). After completion of inflation,the expanded skin flaps were made and transferred to repair the wounds.Results All the 37 expanders were inflated successfully in duration of 46-63 days.Five expansion areas presented complications that were correctly controlled.All of the wounds were covered and healed well after the expanded skin flap transplantation.Twelve patients were followed up for 6 months after operation.The long-term results showed that the color and texture of the flaps matched the recipient sites well without swelling.The aesthetic appearance of the repaired sites looked satisfactory.Conclusions The rapid tissue expansion is a better option for repairs of some skin and soft tissue defects after injury in certain areas.
RESUMEN
Objective: To assess the psychosomatic symptoms in women referred for in vitro fertilization. Methods: The SCL-90 was administered to 100 women referred for IVF (in vitro fertilization and embryo transfer ) and 100 women referred for ICSI (intracytoplasmic sperm injection) at the time of their first presentation to the infertility clinic. The control group comprised of 100 women presenting to gynecology clinics. In addition, socio-demographic information was captured through a structured questionnaire designed for the purpose of this study.Results:The total scores of two study subgroups and control group were 53.8?30.8, 52.5?31.7 and 42.1?32.3 respectively. It was significantly higher score in study groups than that of in control group(F=3.40, P