Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J. vet. sci ; J. vet. sci;: e52-2020.
Artículo | WPRIM | ID: wpr-833683

RESUMEN

Background@#Intradural-intramedullary intervertebral disc extrusion (IIVDE) is a rare condition of intervertebral disc disease. However, the diagnosis of IIVDE is challenging because the prognosis and imaging characteristics are poorly characterized. @*Objectives@#We aimed to describe the clinical and imaging characteristics of tentatively diagnosed IIVDE in dogs to assess the prognostic utility of neurological grade and magnetic resonance imaging (MRI) findings. @*Methods@#Twenty dogs were included in this retrospective cohort study. @*Results@#Nonchondrodystrophic breeds (n = 16) were more predisposed than chondrodystrophic breeds. Most dogs showed acute onset of clinical signs. Neurological examination at admission showed predominant non-ambulatory paraparesis (n = 9); paresis (n = 16) was confirmed more frequently than paralysis (n = 4). Follow-up neurological examination results were only available for 11 dogs, ten of whom showed neurological improvement and 8 showed successful outcomes at 1 month. The characteristic MRI findings include thoracic vertebra (T)2 hyperintense, T1 hypointense, intramedullary linear tracts with reduced disc volume, and cleft of the annulus fibrosus. None of the MRI measurements were significantly correlated with neurological grade at admission. Neurological grade did not differ according to the presence of parenchymal hemorrhage, parenchymal contrast enhancement, and meningeal contrast enhancement. Neurological grades at admission showed a statistical correlation with those observed at the 1-month follow-up (r = 0.814, p = 0.02). @*Conclusions@#IIVDE is a rare form of disc extrusion commonly experienced after physical activity or trauma and most frequently affects the cranial-cervical and thoracolumbar regions of nonchondrodystrophic dog breeds. Neurological score at admission emerged as a more useful prognostic indicator than MRI findings in dogs with suspected IIVDE.

2.
Artículo en Inglés | WPRIM | ID: wpr-760357

RESUMEN

A 6-year-old Dachshund was presented with acute, non-localized pain without neurological dysfunction. Radiography revealed multiple calcifications of intervertebral discs and narrowing of disc space in the thoracolumbar region. Computed tomography and magnetic resonance imaging revealed calcified disc-like material entrapped in the left extraforaminal area and showed a displaced nerve root. Fenestration and removal of the extruded disc material were performed in a routine manner. Histopathological examination showed degenerative disc materials with severe calcification both in the nucleus pulposus and around the annulus fibrosis. Based on imaging, surgical, and histopathologic results, the dog was diagnosed with far lateral lumbar disc extrusion.


Asunto(s)
Animales , Niño , Perros , Humanos , Fibrosis , Disco Intervertebral , Imagen por Resonancia Magnética , Radiografía
3.
J. vet. sci ; J. vet. sci;: e45-2019.
Artículo en Inglés | WPRIM | ID: wpr-758946

RESUMEN

Unenhanced echocardiography (UE), commonly used in veterinary practice, is limited by left ventricular (LV) foreshortening and observer dependency. Contrast echocardiography (CE) was used to compare two-dimensional (2D) LV measurements made using UE and 256-row multi-detector computed tomography (MDCT) as a reference standard. Seven healthy beagle dogs were evaluated in this study. Measurements obtained using CE, including LV wall thickness, internal diameter, and longitudinal and transverse length, were significantly greater than those obtained using UE. Measurements of LV internal dimension in diastole (LVIDd) and systole (LVIDs) were significantly larger with CE compared UE. Regardless of the cardiac cycle, LV longitudinal (LVLd and LVLs) and transverse diameter (LVTDd and LVTDs) measurements were significantly different with CE and approximated values from MDCT. Among automatically calculated parameters, LV end-systolic volume and the relative wall thickness were significantly different between UE and CE. In CE, the correlation coefficients of 4 major parameters (r = 0.87 in LVIDd; 0.91 in LVIDs; 0.87 in LVLd; and 0.81 in LVLs) showed higher values compared to the UE (r = 0.68 in LVIDd, 0.71 in LVIDs, 0.69 in LVLd, and 0.35 in LVLs). Inter-observer agreement was highest for MDCT and higher for CE than UE. In conclusion, CE is more accurate and reproducible than UE in assessing 2D LV measurements and can overcome the limitations of UE including LV foreshortening and high observer dependency.


Asunto(s)
Animales , Perros , Diástole , Ecocardiografía , Tomografía Computarizada Multidetector , Sístole
4.
J. vet. sci ; J. vet. sci;: 73-79, 2017.
Artículo en Inglés | WPRIM | ID: wpr-122307

RESUMEN

This study was performed to identify the relationships between hepatic vein (HV) measurements, including flow velocity and waveform, using pulsed-wave (PW) Doppler ultrasonography, and the severity of tricuspid regurgitation (TR) in dogs. The study included 22 dogs with TR and 7 healthy dogs. The TR group was subdivided into 3 groups according to TR jet profile obtained by echocardiography. The hepatic venous waveform was obtained and classified into 3 types. A variety of HV measurements, including the maximal velocities of the atrial systolic, systolic (S), end ventricular systolic, and diastolic (D) waves and the ratio of the S- and D- wave velocities (S/D ratio), were acquired. TR severity was significantly correlated with the S- (r = −0.380, p = 0.042) and D- (r = 0.468, p = 0.011) wave velocities and the S/D ratio (r = −0.747, p < 0.001). Receiver operating characteristic curve analysis revealed the highest sensitivity and specificity for the S/D ratio (89% and 75%, respectively) at a threshold of 0.97 with excellent accuracy (AUC = 0.911, p < 0.001). In conclusion, PW Doppler ultrasonography of the HV can be used to identify the presence of significant TR and to classify TR severity in dogs.


Asunto(s)
Animales , Perros , Ecocardiografía , Venas Hepáticas , Curva ROC , Sensibilidad y Especificidad , Insuficiencia de la Válvula Tricúspide , Ultrasonografía Doppler
5.
J. vet. sci ; J. vet. sci;: 157-161, 2014.
Artículo en Inglés | WPRIM | ID: wpr-56421

RESUMEN

Positron emission tomography (PET) using 2-deoxy-2-[18F] fluoro-D-glucose (FDG) as a radioactive tracer is a useful technique for in vivo brain imaging. However, the anatomical and physiological features of the Harderian gland limit the use of FDG-PET imaging in the mouse brain. The gland shows strong FDG uptake, which in turn results in distorted PET images of the frontal brain region. The purpose of this study was to determine if a simple surgical procedure to remove the Harderian gland prior to PET imaging of mouse brains could reduce or eliminate FDG uptake. Measurement of FDG uptake in unilaterally adenectomized mice showed that the radioactive signal emitted from the intact Harderian gland distorts frontal brain region images. Spatial parametric measurement analysis demonstrated that the presence of the Harderian gland could prevent accurate assessment of brain PET imaging. Bilateral Harderian adenectomy efficiently eliminated unwanted radioactive signal spillover into the frontal brain region beginning on postoperative Day 10. Harderian adenectomy did not cause any post-operative complications during the experimental period. These findings demonstrate the benefits of performing a Harderian adenectomy prior to PET imaging of mouse brains.


Asunto(s)
Animales , Ratones , Encéfalo/metabolismo , Fluorodesoxiglucosa F18 , Lóbulo Frontal/metabolismo , Glándula de Harder/metabolismo , Ratones Endogámicos BALB C , Neuroimagen/normas , Tomografía de Emisión de Positrones/veterinaria , Radiofármacos
6.
J. vet. sci ; J. vet. sci;: 149-155, 2014.
Artículo en Inglés | WPRIM | ID: wpr-56422

RESUMEN

This study was conducted to evaluate the usefulness of coronary arterial profiles from normal dogs (11 animals) and canines (six dogs) with experimental myocardial infarction (MI) induced by ligation of the left coronary artery (LCA). Blood velocity of the LCA and right coronary artery (RCA) were evaluated following transthoracic pulsed-wave Doppler echocardiography. The LCA was observed as an infundibular shape, located adjacent to the sinus of Valsalva. The RCA appeared as a tubular structure located 12 o'clock relative to the aorta. In normal dogs, the LCA and RCA mean peak diastolic velocities were 20.84 +/- 3.24 and 19.47 +/- 2.67 cm/sec, respectively. The LCA and RCA mean diastolic deceleration times were 0.91 +/- 0.14 sec and 1.13 +/- 0.20 sec, respectively. In dogs with MI, the LCA had significantly (p < 0.01) lower peak velocities (14.82 +/- 1.61 cm/sec) than the RCA (31.61 +/- 2.34 cm/sec). The RCA had a significantly (p < 0.01) rapid diastolic deceleration time (0.71 +/- 0.06 sec) than that found in the LCA (1.02 +/- 0.22 sec) of MI dogs. In conclusion, these profiles may serve as a differential factor for evaluating cardiomyopathy in dogs.


Asunto(s)
Animales , Femenino , Masculino , Velocidad del Flujo Sanguíneo/veterinaria , Vasos Coronarios/cirugía , Enfermedades de los Perros/diagnóstico , Perros/fisiología , Ecocardiografía Doppler de Pulso/normas , Infarto del Miocardio/diagnóstico
7.
J. vet. sci ; J. vet. sci;: 401-405, 2008.
Artículo en Inglés | WPRIM | ID: wpr-65388

RESUMEN

Tracheal ultrasonography was performed to measure the width of the tracheal ring shadow and to assess the clinical relevance of these measurements for identifying tracheal collapse. The first tracheal ring width (FTRW) and thoracic inlet tracheal ring width (TITRW) were measured on both expiration and inspiration. The mean of the FTRW width (129 dogs) was greater in expiration (10.97 +/- 1.02 mm, p = 0.001) than that in inspiration (9.86 +/- 1.03 mm). For 51 normal dogs, the mean of the TITRW width was greater in expiration (9.05 +/- 1.52 mm, p = 0.001) than in inspiration (8.02 +/- 1.43 mm). For 78 tracheal collapse dogs, the mean of the TITRW width was greater in expiration (15.89 +/- 1.01 mm, p = 0.001) than in inspiration (14.85 +/- 1.17 mm). The TITRW/FTRW ratio of the normal dogs was higher (p = 0.001) in expiration (0.81 +/- 0.09) than that in inspiration (0.79 +/- 0.10). When compared between the normal and tracheal collapse dogs, the TITRW/FTRW ratio was also increased (p = 0.001) both in expiration (1.54 +/- 0.09) and inspiration (1.47 +/- 0.08), respectively. Based on these results, the cutoff level of the TITRW/FTRW ratio was statistically analyzed according to the receiver operating characteristic curve and it could be set at 1.16 in expiration and at 1.13 in inspiration. We have demonstrated that tracheal ultrasonography is a useful technique for the evaluation of tracheal collapse and it can be a supportive tool together with the radiographic findings for making the correct diagnosis.


Asunto(s)
Animales , Perros , Femenino , Masculino , Enfermedades de los Perros/diagnóstico , Radiografía Torácica/veterinaria , Sensibilidad y Especificidad , Tráquea/patología , Estenosis Traqueal/diagnóstico
8.
J. vet. sci ; J. vet. sci;: 397-399, 2006.
Artículo en Inglés | WPRIM | ID: wpr-167594

RESUMEN

This study was performed to radiographically examine the prevalence of aspiration sites and to evaluate their atomical correlation with the bronchial pattens. Ten healthy beagle dogs were repeatedly radiographed, at weekly intervals, in the left and right lateral, ventrodorsal (VD) and dorsoventral (DV) positions. Three mililiters of iohexol distilled with same volume of saline was infused into the tracheal inlet. Which lung lobe was aspirated was decided upon by the presence of a significant alveolar pattern due to the contrast medium. Alveolar patterns were identified at the left (100%) and right cranial lung lobes (77%) with the dogs in dependant lateral recumbency, at the right caudal lung lobe (71%) with the dogs in VD recumbency and at the right middle lung lobe (59%) with the dogs in DV recumbency, respectively. The anatomical correlation was evaluated by performing computed tomography. The right principal bronchus (165.8 +/- 1.6 degrees) was more straightly bifurcated than was the left principal bronchus (142.7 +/- 1.8 degrees, p < 0.01). In VD position, the right side lung had a greater opertunity to become aspirated. The ventrally positioned right middle lobar bronchial origin was more easily to be aspirated the other laterally positioned ones. We think that these anatomical characteristics can be one of the causes for aspiration pneumonia to occur more frequently in the right side lung.


Asunto(s)
Animales , Perros , Femenino , Masculino , Medios de Contraste/química , Enfermedades de los Perros/patología , Yohexol/química , Neumonía por Aspiración/patología , Tomografía Computarizada por Rayos X/veterinaria
9.
J. vet. sci ; J. vet. sci;: 163-171, 2004.
Artículo en Inglés | WPRIM | ID: wpr-128636

RESUMEN

The present study was performed to determine the accuracy and reproducibility of calculating the mitral regurgitant orifice area with the proximal isovelocity surface area (PISA) method in dogs with experimental mitral regurgitation and in canine patients with chronic mitral insufficiency and to evaluate the effect of general anesthesia on mitral regurgitation. Eight adult, Beagle dogs for experimental mitral regurgitation and 11 small breed dogs with spontaneous mitral regurgitation were used. In 8 Beagle dogs, mild mitral regurgitation was created by disrupting mitral chordae or leaflets. Effective regurgitant orifice (ERO) area was measured by the PISA method and compared with the measurements simultaneously obtained by quantitative Doppler echocardiography 4 weeks after creation of mitral regurgitation. The same procedure was performed in 11 patients with isolated mitral regurgitation and in 8 Beagle dogs under two different protocols of general anesthesia. ERO and regurgitant stroke volume (RSV) by the PISA method correlated well with values by the quantitative Doppler technique with a small error in experimental dogs (r = 0.914 and r = 0.839) and 11 patients (r = 0.990 and r = 0.996). The isoflurane anesthetic echocardiography demonstrated a significant decrease of RSV, and there was no significant change in fractional shortening (FS), ERO area, LV end-diastolic and LV end-systolic volume. ERO area showed increasing tendency after ketamine-xylazine administration, but not statistically significant. RSV, LV end-systolic and LV end-diastolic volume increased significantly (p < 0.01), whereas FS significantly decreased (p < 0.01). The PISA method is accurate and reproducible in experimental mitral regurgitation model and in a clinical setting. ERO area is considered and preferred as a hemodynamic-nondependent factor than other traditional measurements.


Asunto(s)
Animales , Perros , Anestesia Rectal , Mapeo del Potencial de Superficie Corporal/veterinaria , Cuerdas Tendinosas/fisiopatología , Enfermedades de los Perros/diagnóstico , Ecocardiografía Doppler/veterinaria , Electrocardiografía/veterinaria , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA