Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Clinical Pain ; (2): 104-114, 2023.
Artículo en Inglés | WPRIM | ID: wpr-1040593

RESUMEN

Objective@#The objective of this study is to assess the efficacy and safety of repeated sodium polynucleotide (Conjuran Ⓡ ) treatments in patients with knee osteoarthritis. Methods: The study was conducted by retrospectively examining 45 patients who repeated the treatment course of 5 injections of Conjuran Ⓡ twice within 6 months. For each course, pain reduction by the change of 100-mm Weight-Bearing-Pain Visual-Analog-Scale was compared with before administration until 6 months after administration. Improvement by Clinical Global Impression (CGI) and Patient Global Impression (PGI) were also investigated, as well as adverse reactions. @*Results@#Pain analysis after administration of Conjuran Ⓡ confirmed that VAS decreased by 51.6% until 6 months (p<0.001), and after that the effect was lost and was repeat for the 2 nd course. In the 2 nd , VAS continued to decrease by 58.7% compared to before the 1 st course (p<0.001). Analysis of CGI, 88.9% of patients improved after the 1 st and 84.4% of patients improved after the 2 nd . In the PGI results, symptoms improved in 86.7% of patients after the 1 st and 82.2% after the 2 nd . No significant adverse event was reported. @*Conclusion@#The safety and efficacy results of patients receiving Conjuran Ⓡ for 2 nd treatment courses were similar to those for 1 st treatment course. In addition, the effect lasts for up to 6 months after administration, and the pain reduction effect is lost thereafter, so it is recommended to apply it at 6-month intervals if additional treatment is needed. Conjuran Ⓡ is an intra-articular injection that is effective in reducing knee pain and can be used repeatedly without adverse reactions.

2.
Artículo en Inglés | WPRIM | ID: wpr-759180

RESUMEN

PURPOSE: The purpose of this study was to compare the mechanical stability of three types of plate systems for opening wedge high tibial osteotomy. MATERIALS AND METHODS: Forty-eight fresh frozen porcine tibia specimens were assigned to three different fixation device groups: Aescular group (16 specimens) was fixed with Aescular plates; Puddu group (16 specimens) with a Puddu plate, and TomoFix group (16 specimens) with a TomoFix plate. We compared axial displacements under compression loads from 200 to 2,000 N and maximal loads at failure among 8 specimens per group. We also compared displacements under cyclic load after 100 cycles at a compressive load of 2,000 N among 8 specimens per group. RESULTS: In all three groups, displacement under compression load increased with the increase in the axial compressive load; however, no significant intergroup differences were observed in the mean values under tested loading conditions. The mean maximal loads at failure were not significantly different (6,055, 6,798, and 6,973 N in the Aescular, Puddu, and TomoFix groups, respectively; p=0.41). While the TomoFix group showed less extension and strain during the cyclic load test, the mean values showed no significant differences among groups. CONCLUSIONS: All three plate systems were found to provide fixation stability suitable for bearing axial compression and cyclic loads while walking.


Asunto(s)
Rodilla , Osteotomía , Tibia , Caminata
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA