Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Mycobiology ; : 131-136, 2005.
Artículo en Inglés | WPRIM | ID: wpr-730056

RESUMEN

Infection structures were observed at the penetration sites on the leaves of cucumber plants inoculated with Colletotrichum orbiculare using a fluorescence microscope. The cucumber plants were previously drenched with suspension of bacterial strains Pseudomonas putida or Micrococcus luteus. The plants pre-inoculated with both bacterial strains were resistant against anthracnose after inoculation with C. orbiculare. To investigate the resistance mechanism by both bacterial strains, the surface of infected leaves was observed at the different time after challenge inoculation. At 3 days after inoculation there were no differences in the germination and appressorium formation of conidia of C. orbiculare as well as in the callose formation of the plants between both bacteria pre-inoculated and non-treated. At 5 days, the germination and appressorium formation of the fungal conidia were, however, significantly decreased on the leaves of plants pre-inoculated with M. luteus at the concentration with 1.0 x 10(7) cfu/ml. Furthermore, callose formation of plants cells at the penetration sites was apparently increased. In contrast, there were no defense reactions of the plants at the concentration with 1.0 x 10(6) cfu/ml of M. luteus. Similarly, inoculation P. putida caused no plant resistance at the low concentration, whereas increase of callose formation was observed at the higher concentration. The results of this study suggest that the resistant mechanisms might be differently expressed by the concentration of pre-treatment with bacterial suspension.


Asunto(s)
Bacterias , Colletotrichum , Fluorescencia , Germinación , Micrococcus luteus , Micrococcus , Plantas , Pseudomonas putida , Pseudomonas , Esporas Fúngicas
2.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 66-73, 2001.
Artículo en Coreano | WPRIM | ID: wpr-76512

RESUMEN

PURPOSE: For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. METHOD AND MATERIALS: For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, EIC-1 ion chambers manufactured by A-150 plastic and used IC-17M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was 5 cc per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. RESULTS: The absorbed dose of fast neutron beams was 6.47x10-3 cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was 65.2+/-0.9% at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, D20/D10, of the total dose was 0.718. CONCLUSION: Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.


Asunto(s)
Argón , Bismuto , Terapia por Captura de Neutrón de Boro , Boro , Ciclotrones , Suministros de Energía Eléctrica , Neutrones Rápidos , Esperanza , Corea (Geográfico) , Magnesio , Neutrones , Reactores Nucleares , Parafina , Plásticos , Agua
3.
Journal of the Korean Society of Plastic and Reconstructive Surgeons ; : 633-637, 1992.
Artículo en Coreano | WPRIM | ID: wpr-50046

RESUMEN

No abstract available.


Asunto(s)
Fascia , Surco Nasolabial
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA