RESUMEN
ABSTRACT Objective To describe a more accurate method for measuring the pelvic incidence angle using computed tomography, without the influence of the positioning of the pelvis in relation to the X-ray tube. Methods Thirteen CT scans of the lumbosacral region, abdomen or pelvis were randomly assessed, as all these exams include the sacrum and femoral heads. All the exams were performed in multichannel devices with six channels. The technique of overlapping images, already common in other musculoskeletal exams, such as TT-TG, was used. The centered sagittal cut of the left femoral head, the center of S1, and the right femoral head were used. From these, a fourth image was created, analogous to an X-ray of the pelvis, from which measurements were taken using the dedicated software. Results Of the thirteen exams, three were of the lumbar spine and 10 were of the total abdomen, six of them being of males.. The mean age was 56 years. The mean PI was 45°, ranging from 31 to 81 degrees. Among the women, the mean was 52° (31 to 81°) and among the men, 38° (32 to 46°). Conclusion CT can be used to calculate the PI, using the technique of overlapping images common to other musculoskeletal exams, such as TT-TG. Level of Evidence IIIB. Diagnostic study; Retrospective study.
RESUMO Objetivo Descrever um método mais preciso para medição do ângulo de incidência pélvica, utilizando a tomografia computadorizada, sem influência do posicionamento da pelve em relação à ampola de raio-x. Métodos Foram avaliados, de modo aleatório, 13 exames de TC da coluna lombossacra, abdome total ou pelve, já que englobam o sacro e as cabeças femorais. Todos os exames foram realizados em aparelhos multicanais com 6 canais. Utilizou-se a técnica de sobreposição de imagens, comum em outros exames musculoesqueléticos como TT-TG. Foi selecionado o corte sagital centrado da cabeça femoral esquerda, centro do platô de S1 e cabeça femoral direita. A partir de então, foi criada uma quarta imagem, análoga a uma radiografia da pelve, em que foram realizadas as medidas, utilizando o software dedicado. Resultados Dos 13 exames, três eram da coluna lombar e 10 do abdome total, sendo que seis eram do sexo masculino. A média de idade foi de 56 anos. A média da IP foi de 45°, variando entre 31 e 81. Entre as mulheres, a média foi de 52° (31° a 81°) e entre os homes de 38° (32° e 46°). Conclusão A TC pode ser utilizada para o cálculo da IP, utilizando a técnica de sobreposição de imagens comum em outros exames musculoesqueléticos como TT-TG. Nível de Evidência IIIB. Estudo diagnóstico. Estudo retrospectivo.
RESUMEN Objetivo Describir un método más preciso para medición del ángulo de incidencia pélvica, utilizando la tomografía computarizada, sin influencia del posicionamiento de la pelvis con relación a la ampolla de rayos x. Métodos Fueron evaluados, de modo aleatorio, 13 exámenes de TC de columna lumbosacra, abdomen total o pelvis, pues engloban el sacro y cabezas femorales. Todos los exámenes se realizaron en aparatos multicanales con seis canales. Se utilizó la técnica de superposición de imágenes, común en otros exámenes musculoesqueléticos como TT-TG. Se seleccionó el corte sagital centrado de la cabeza femoral izquierda, centro de S1 y centro de la meseta de S1 y cabeza femoral derecha. A partir de entonces, fue creada una cuarta imagen, análoga a una radiografía de la pelvis, en que fueron realizadas las medidas, utilizando el software dedicado. Resultados De los 13 exámenes, tres eran de columna lumbar y 10 de abdomen total, siendo que seis eran del sexo masculino. El promedio de edad fue de 56 años. El promedio de la IP fue de 45°, variando entre 31 y 81. Entre las mujeres, el promedio fue de 52° (31 a 81°) y entre los hombres de 38° (32 y 46°). Conclusión La TC puede ser utilizada para el cálculo de la IP, utilizando la técnica de superposición de imágenes común en otros exámenes musculoesqueléticos como TT-TG. Nivel de Evidencia IIIB. Estudio diagnóstico. Estudio retrospectivo.