Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. j. phys. ther. (Impr.) ; 20(5): 395-404, Sept.-Oct. 2016. tab
Artículo en Inglés | LILACS | ID: biblio-828291

RESUMEN

ABSTRACT Background Muscle strength is usually measured in individuals with stroke with Portable dynamometers (gold standard). However, no studies have investigated the reliability, the standard error of measurement (SEM) and the minimal detectable difference (MDD95%) of the dynamometry for the measurement of hand grip, pinch grip and trunk strength in subjects with subacute stroke. Objective 1) To investigate the intra and inter-rater reliability, the SEM and the MDD95% of the portable dynamometers for the measurement of grip, pinch and trunk strength in subjects with subacute stroke, and 2) to verify whether the use of different number of trials (first trial and the average of the first two and three trials) affected the results. Method 32 subjects with subacute stroke (time since stroke onset: 3.6 months, SD=0.66 months) were evaluated. Hand grip, 3 pinch grips (i.e. pulp-to-pulp/palmar/lateral) and 4 trunk muscles (i.e. flexors, extensors, lateral flexors and rotators) strength were bilaterally assessed (except trunk flexors/extensors) with portable dynamometry by two independent examiners over two sessions (1-2 weeks apart). One-way ANOVAs and intraclass correlation coefficients (ICC2,k) were used for analysis (α=0.05). SEM and MDD95% were also calculated. Results For all muscular groups and sources of outcome values, including one trial, after familiarization, similar results were found (0.01≤F≤0.08; 0.92≤p≤0.99) with significant and adequate values of intra-rater (0.64≤ICC≤0.99; 0.23≤95%CI≤0.99) and inter-rater (0.66≤ICC≤0.99; 0.25≤95%CI≤0.99) reliability. SEM and MDD95% were considered low (0.39≤EPM≤2.21 Kg; 0.96≤MMD95%≤6.12 Kg) for all outcome scores. Conclusion Only one trial, following familiarization, demonstrated adequate intra-rater and inter-rater reliability of the portable dynamometers for the measurement of hand grip, pinch grip and trunk strength in subjects with subacute stroke.


Asunto(s)
Humanos , Músculo Esquelético/fisiología , Fuerza de la Mano/fisiología , Accidente Cerebrovascular/fisiopatología , Fuerza Muscular/fisiología , Rehabilitación de Accidente Cerebrovascular/normas , Reproducibilidad de los Resultados , Accidente Cerebrovascular/complicaciones , Extremidad Superior/fisiología , Extremidad Superior/patología
2.
Braz. j. phys. ther. (Impr.) ; 19(6): 498-506, Nov.-Dec. 2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-767070

RESUMEN

ABSTRACT Background: Grip strength, commonly evaluated with the handgrip dynamometer, is a good indicator of upper limb (UL) function in stroke subjects and may reflect the global strength deficits of the whole paretic UL. The Modified Sphygmomanometer Test (MST) also provides objective and adequate measures at low-cost. Objective: To assess whether grip strength values obtained by using the MST and those obtained by using a handgrip dynamometer would present similar correlations with the global strength and motor function of the paretic UL in subjects with stroke, both in the subacute and chronic phases. Method: Measures of grip strength (MST and handgrip dynamometer), UL global strength (MST and hand-held dynamometer), and UL motor function (Fugl-Meyer motor assessment scale) were obtained with 33 subacute and 44 chronic stroke subjects. Pearson and Spearman correlation coefficients were calculated and Stepwise multiple regression analyses were performed to investigate predictor variables of grip strength (α=0.05). Results: Significant correlations of similar magnitude were found between measures of global strength of the paretic UL and grip strength assessed with both the MST (0.66≤r≤0.78) and handgrip dynamometer (0.66≤r≤0.78) and between UL motor function and grip strength assessed with both the MST (0.50≤rs≤0.51) and hand-held dynamometer (0.50≤rs≤0.63) in subacute and chronic stroke subjects. Only global strength remained as a significant predictor variable of grip strength for the MST (0.43≤R2≤0.61) and for the handgrip dynamometer (0.44≤R2≤0.61) for both stroke subgroups. Conclusion: Grip strength assessed with the MST could be used to report paretic UL global strength.


Asunto(s)
Humanos , Fuerza de la Mano/fisiología , Esfigmomanometros/normas , Accidente Cerebrovascular/fisiopatología , Extremidad Superior/fisiopatología , Fuerza Muscular/fisiología , Rehabilitación de Accidente Cerebrovascular/métodos , Rehabilitación de Accidente Cerebrovascular/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA