Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Chinese Medical Journal ; (24): 2785-2791, 2018.
Artículo en Inglés | WPRIM | ID: wpr-772920

RESUMEN

Background@#Automated peritoneal dialysis (APD) can cater to individual needs, provide treatment while asleep, take into account the adequacy of dialysis, and improve the quality of life. Currently, independent research and development of APD machines made in China are more conducive to patients. A randomized, multicenter, crossover study was conducted by comparing an APD machine made in China with an imported machine. The safety, effectiveness, and manipulability of the two machines were compared.@*Methods@#Two hundred and sixty patients who underwent peritoneal dialysis (PD) on a regular basis in 18 centers between August 2015 and February 2016 were included. The inclusion criteria include age ≥18 years and PD ≥30 days. The exclusion criteria were as follows: hemodialysis; exit site or tunnel infection; and peritonitis ≤30 days. The patients were randomly divided into Group A, who were first treated with a FM machine made in China, then changed to an imported machine; and Group B, who were treated using the reverse sequence. APD treatment was performed with 10 L/10 h and 5 cycles of exchange. After 72 h, the daily peritoneal Kt/V, the accuracy of the injection rate, accuracy of the injection temperature, safety, and manipulability of the machine were assessed. Noninferiority test was conducted between the two groups.@*Results@#The daily peritoneal Kt/V in the APD machine made in China and the imported APD machine were 0.17 (0.14, 0.25) and 0.16 (0.13, 0.23), respectively. There was no significant difference between the groups (Z = 0.15, P = 0.703). The lower limit of the daily Kt/V difference between the two groups was 0.0069, which was greater than the noninferiority value of -0.07 in this study. The accuracy of the injection rate and injection temperature was 89.7% and 91.5%, respectively, in the domestic APD machine, which were both slightly better than the accuracy rates of 84.0% and 86.8% in the imported APD machine (89.7% vs. 84.0%, P = 0.2466; 91.5% vs. 86.8%, P = 0.0954). Therefore, the APD machine made in China was not inferior to the imported APD machine. The fuselage of the imported APD machine was space-saving, while the APD machine made in China was superior with respect to body mobility, man-machine dialog operation, alarm control, and patient information recognition.@*Conclusions@#The FM machine made in China was not inferior to the imported APD machine. In addition, the FM machine made in China had better operability.@*Trial Registration@#Clinicaltrials.gov, NCT02525497; https://clinicaltrials.gov/ct2/results?cond=&term=NCT02525497&cntry=& state=&city=&dist=.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , China , Estudios Cruzados , Estudios Multicéntricos como Asunto , Diálisis Peritoneal , Métodos , Calidad de Vida , Temperatura
2.
Chinese Medical Journal ; (24): 885-891, 2017.
Artículo en Inglés | WPRIM | ID: wpr-266889

RESUMEN

<p><b>BACKGROUND</b>Patients on hemodialysis have a high-mortality risk. This study analyzed factors associated with death in patients on maintenance hemodialysis (MHD). While some studies used baseline data of MHD patients, this study used the most recent data obtained from patients just prior to either a primary endpoint or the end of the study period to find the characteristics of patients preceding death.</p><p><b>METHODS</b>Participants were selected from 16 blood purification centers in China from January 2012 to December 2014. Patients' data were collected retrospectively. Based on survival status, the participants were divided into two groups: survival group and the death group. Logistic regression analysis was performed to determine factors associated with all-cause mortality.</p><p><b>RESULTS</b>In total, 4104 patients (57.58% male, median age 59 years) were included. Compared with the survival group, the death group had more men and more patients with diabetic nephropathy (DN) and hypertensive nephropathy. The patients preceding death also had lower levels of diastolic blood pressure, hemoglobin, serum albumin, serum calcium, serum phosphate, Kt/V, and higher age. Multivariate analysis revealed that male sex (odd ratio [OR]: 1.437, 95% confidence interval [CI]: 1.094-1.886), age (OR: 1.046, 95% CI: 1.036-1.057), and presence of DN (OR: 1.837, 95% CI: 1.322-2.552) were the risk factors associated with mortality. High serum calcium (OR: 0.585, 95% CI: 0.346-0.989), hemoglobin (OR: 0.974, 95% CI: 0.967-0.981), albumin (OR: 0.939, 95% CI: 0.915-0.963) levels, and dialysis with noncuffed catheter (OR: 0.165, 95% CI: 0.070-0.386) were protective factors based on a multivariate analysis.</p><p><b>CONCLUSIONS</b>Hemodialysis patients preceding death had lower hemoglobin, albumin, and serum calcium levels. Multivariate analysis showed that male sex, age, DN, low hemoglobin, low albumin, and low serum calcium were associated with death in hemodialysis patients.</p>


Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , China , Análisis Multivariante , Diálisis Renal , Mortalidad , Estudios Retrospectivos , Factores de Riesgo
3.
Chinese Medical Journal ; (24): 2276-2280, 2013.
Artículo en Inglés | WPRIM | ID: wpr-272995

RESUMEN

<p><b>BACKGROUND</b>Data on the epidemiology of hypertension in Chinese non-dialysis chronic kidney disease (CKD) patients are limited. The aim of the present study was to investigate the prevalence, awareness, treatment, and control of hypertension in the non-dialysis CKD patients through a nationwide, multicenter study in China.</p><p><b>METHODS</b>The survey was performed in 61 tertiary hospitals in 31 provinces, municipalities, and autonomous regions in China (except Hong Kong, Macao, and Taiwan). Trained physicians collected demographic and clinical data and measured blood pressure (BP) using a standardized protocol. Hypertension was defined as systolic BP ≥ 140 mmHg and/or diastolic BP ≥ 90 mmHg, and/or use of antihypertensive medications. BP < 140/90 mmHg and < 130/80 mmHg were used as the 2 thresholds of hypertension control. In multivariate logistic regression with adjustment for sex and age, we analyzed the association between CKD stages and uncontrolled hypertension in non-dialysis CKD patients.</p><p><b>RESULTS</b>The analysis included 8927 non-dialysis CKD patients. The prevalence, awareness, and treatment of hypertension in non-dialysis CKD patients were 67.3%, 85.8%, and 81.0%, respectively. Of hypertensive CKD patients, 33.1% and 14.1% had controlled BP to < 140/90 mmHg and < 130/80 mmHg, respectively. With successive CKD stages, the prevalence of hypertension in non-dialysis CKD patients increased, but the control of hypertension decreased (P < 0.001). When the threshold of BP < 130/80 mmHg was considered, the risk of uncontrolled hypertension in CKD 2, 3a, 3b, 4, and 5 stages increased 1.3, 1.4, 1.4, 2.5, and 4.0 times compared with CKD 1 stage, respectively (P < 0.05). Using the threshold of < 140/90 mmHg, the risk of uncontrolled hypertension increased in advanced stages (P < 0.05).</p><p><b>CONCLUSIONS</b>The prevalence of hypertension Chinese non-dialysis CKD patients was high, and the hypertension control was suboptimal. With successive CKD stages, the risk of uncontrolled hypertension increased.</p>


Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Concienciación , Hipertensión , Epidemiología , Terapéutica , Prevalencia , Insuficiencia Renal Crónica
4.
Chinese Medical Journal ; (24): 4204-4209, 2013.
Artículo en Inglés | WPRIM | ID: wpr-327602

RESUMEN

<p><b>BACKGROUND</b>A multi-center large scale study is needed to confirm the efficacy and safety of domestic peritoneal dialysis (PD) solutions. Some researchers believe that 6 L/d is enough for adequate dialysis, but there is no multi-center prospective study on Chinese population to confirm this. In this study, we evaluated the efficacy and safety of domestic PD solution (Changfu) and its difference between 6 L and 8 L dosage.</p><p><b>METHODS</b>Adult PD patients who had taken PD therapy for at least one month were selected and divided into four groups according to two dialysis solution brands and two dialysis dosages, i.e., 6 L dose with Changfu dialysis solution, 6 L dose with Baxter dialysis solution, 8 L dose with Changfu dialysis solution, and 8 L dose with Baxter dialysis solution. After 48 weeks, the changes of primary and secondary efficacy indices were compared between different types and different dosages. We also analyzed the changes of safety indices.</p><p><b>RESULTS</b>Changes of Kt/V from baseline to 48 weeks between Changfu and Baxter showed no statistical differences; so did those of creatinine clearance rate (Ccr). Normalized protein catabolic rate (nPCR) from baseline to 48 weeks between Changfu and Baxter showed no statistical differences; so did those of net ultrafiltration volume (nUF) and estimated glomerular filtration rate (eGFR). Changes of nPCR from baseline to 48 weeks between 6 L and 8 L showed no statistical differences; so did those of nUF and eGFR. The decline of Kt/V from baseline to 48 weeks in 6 L group was more than that in 8 L group. Change of Ccr was similar. During the 48-week period, the mean Kt/V was above 1.7/w, and mean Ccr was above 50 L×1.73 m(-2)×w(-1). More adverse events were found in Changfu group before Changfu Corporation commenced technology optimization, and the statistical differences disappeared after that.</p><p><b>CONCLUSIONS</b>The domestic PD solution (Changfu) was proven to be as effective as Baxter dialysis solution. During 48-week period, a dosage of 6 L/d was enough for these patients to reach adequate PD. Clinical study promotes technological optimization, further helps to improve the safety indices of the medical products.</p>


Asunto(s)
Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Soluciones para Diálisis , Usos Terapéuticos , Diálisis Peritoneal , Métodos
5.
Chinese Journal of Nephrology ; (12)2005.
Artículo en Chino | WPRIM | ID: wpr-679557

RESUMEN

Objective To investigate the effect of angiotensinⅡ(AngⅡ) type 1 receptor blocker losartan on the cyclooxygenase 2 (COX-2) expression in metabolic syndrome (MS)kidney. Methods Seven-week-old male obese Zucker rats,a model of MS,were randomly divided into losartan treated and untreated group,and lean Zucker rats were used as controls.The obese Zucker rata of treated group received losartan for 4 months continuously.COX-2 expression was examined for all rats after 4 months.AngⅡ-stimulated mesangial cells and cortical tissue from AngⅡ-infused C57BL/6 mouse kidney by osmotic minipumps were used in this study.RNA and protein were obtained from renal cortical tissue or mesangial cells for RT-PCR and Western blot.Results Compared to the lean controls,obese Zucker rats showed a significant increase of COX-2 expression in the renal cortical tissue and these abnormalities were prevented by administration of losartan. Furthermore,the direct stimulation of AngⅡincreased COX-2 expression in mesangial cells in vitro and renal cortical tissue in vivo.Conclusions MS-induced COX-2 expression in the kidney is regulated by AngⅡ.Losartan as a non COX-2 inhibitor can protect MS kidney,at least in part,by inhibition of COX-2 activation.

6.
Chinese Journal of Nephrology ; (12)2005.
Artículo en Chino | WPRIM | ID: wpr-679497

RESUMEN

Objective To investigate the effect of 12-lipoxygenase (12-LO) on the angiotensinⅡtype 1 receptor(ATlR) expression in mesangial cells (MC).Methods p38 MAPK activation and ECM protein expression were determined using AngⅡ-stimulated MC derived from normal and 12-LO knockout mice.AT1R expression was determined using 12-LO product 12(S)- HETE-stimulated MC,MC transfected with 12-LO gene and microdissected glomeruli derived from 12-LO knockout mice.RT-PCR and Western blot were used for evaluating mRNA and protein expression respectively.Results AngⅡstimulation increased p38 MAPK activation and ECM protein expression in normal MC,but not in MC derived from 12-LO knockout mice.Time-dependent and dose-dependent experiment showed that 12 (S)- HETE increased AT1R protein' expression in MC. Similarly,12 (S)-HETE increased AT1R mRNA expression in MC compared with control MC (P<0.01). Furthermore,AT1R expression was lower in glomeruli derived from 12-LO knockout mice relative to genetic controls (P<0.01) and MC stably overexpressing 12-LO had greater AT1R protein and mRNA expression relative to control MC (P<0.01).Conclusion 12-LO activation can upregulate ATIR expression in MC.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA