Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Acta Academiae Medicinae Sinicae ; (6): 53-56, 2021.
Artículo en Chino | WPRIM | ID: wpr-878698

RESUMEN

Objective To compare the differences of energy spectrum CT between small cell lung cancer(SCLC)with mediastinal lymph node metastasis and mediastinal sarcoidosis.Methods Twenty-five SCLC patients with mediastinal lymph node metastasis(SCLC group)and 26 patients with mediastinal sarcoidosis(sarcoidosis group)confirmed by bronchoscopy and biopsy in Tangshan People's Hospital from January 2018 to June 2019 were selected as the research objects.The CT value,iodine concentration,water concentration and energy spectrum curve slope under different single energy levels were compared between SCLC group and sarcoidosis group.Results The single-energy CT values of 40-80 keV segments in the arterial phase of the SCLC group were significantly higher than those in the sarcoidosis group(all P 0.05).The single-energy CT values of 40-90 keV segments in venous phase of the SCLC group were significantly higher than those of the sarcoidosis group(all P 0.05).The concentrations of iodine in the arterial phase and venous phase of the SCLC group were(11.56±4.06)μg/cm


Asunto(s)
Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Ganglios Linfáticos , Metástasis Linfática , Sarcoidosis/diagnóstico por imagen , Carcinoma Pulmonar de Células Pequeñas/diagnóstico por imagen , Tomografía Computarizada por Rayos X
2.
Acta Academiae Medicinae Sinicae ; (6): 431-435, 2020.
Artículo en Chino | WPRIM | ID: wpr-826343

RESUMEN

To investigate the differences in energy spectrum CT findings between anterior mediastinal lymphoma and thymic carcinoma. Twenty-two cases of anterior mediastinal lymphoma and 28 cases of thymic carcinoma confirmed by biopsy in Tangshan People's Hospital were selected.The CT values and changes of iodine content and water content in lesion sites were measured by energy spectrum analysis software.The differences between anterior mediastinal lymphoma and thymic carcinoma were compared. The single-energy CT value of 40-80 keV in thymus carcinoma was higher than that in anterior mediastinal lymphoma(=0.001,=0.037,=0.042,=0.034,=0.002;=0.016,=0.013,=0.018,=0.024,=0.012).The difference in the single-energy CT value of 90-110 keV between anterior mediastinal lymphoma and thymic carcinoma showed no statistical significance(all >0.05).The concentrations of water in the arterial and venous stages of thymic carcinoma were significantly lower than those in the anterior mediastinal lymphoma(=0.030,=0.037),whereas the iodine concentrations were significantly higher(=0.026,=0.000). Anterior mediastinal lymphoma and thymic carcinoma have remarkably different 40-80 keV single energy CT value and iodine concentration in arterial and venous phases,which may be helpful for the differential diagnosis of these two malignancies.


Asunto(s)
Humanos , Linfoma , Diagnóstico por Imagen , Neoplasias del Mediastino , Diagnóstico por Imagen , Timoma , Diagnóstico por Imagen , Neoplasias del Timo , Diagnóstico por Imagen , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA