Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Radiology ; (12): 679-683, 2023.
Artículo en Chino | WPRIM | ID: wpr-992997

RESUMEN

Objective:To explore the value of echo-planar imaging correction (EPIC) for improving image quality of diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) of cervical cord.Methods:A total of 33 subjects (20 males, 13 females) were scanned on a 3.0 T MR scanner from January to March 2022, and the sequences included T 1WI, DWI and DTI (with and without corrections). Two observers delineated the regions of interest (ROIs) on the fused images of DWI and DTI with T 1WI before and after correction, and measured the average diffusion coefficient (ADC), fractional anisotropy (FA), and offset distance of ROIs between images with and without corrections. The subjective scores of image quality were also evaluated. The ICC or Kappa was used to test the consistency of the quantitative measurement and subjective scores by the two observers. The average values by the two observers would be used for subsequent analysis. The independent pair t-test and Wilcoxon test were used for comparison of objective measurements and Mann-Whitney U test was used for subjective image assessments between images with and without corrections. Results:The measurement data and the subjective scores of the two observers were in good agreement (ICC 0.912-0.999, Kappa 0.778-0.816). The independent sample t-test showed the subjective scores were significantly different for the DWI and DTI images between before and after geometry and/or ADC corrections. The ADC values of C6, the offset distances measured by DWI before and after correction of C4, C5, and C6 and subjective scores were significantly different ( P<0.05); The FA values of C1 and C3, ADC values of C1 and C3, offset distance of C4, C5 and C6 measured by DTI before and after correction and subjective scores were statistically significant ( P<0.001). Conclusion:EPI geometry correction and ADC value correction can significantly reduce geometric distortion, increase image quality, and thus improve the diagnosis accuracy of essential diseases.

2.
Chinese Journal of Radiology ; (12): 294-299, 2023.
Artículo en Chino | WPRIM | ID: wpr-992962

RESUMEN

Objective:To explore the consistency of MRI fast field echo resembling a CT using restricted echo-spacing (FRACTURE) and CT in the evaluation of knee and ankle bone changes.Methods:From November 2020 to November 2021, seventeen patients who underwent CT and MRI FRACTURE examinations of knee joint or ankle joint in the First Affiliated Hospital of Dalian Medical University were retrospectively collected, including 14 patients with knee joint examinations and 3 patients with ankle joint examinations. According to the number of joint components, 80 components were included, including 14 for femur and patella, 17 for tibia and fibula, and 3 for talus, scaphoid, medial cuneiform, medial cuneiform, lateral cuneiform and calcaneus, respectively. The fracture, hyperosteogeny, and bone destruction of the joint bones were evaluated by two observers using CT and FRACTURE images, respectively. Kappa test was used to analyze the consistency of CT and FRACTURE images between observers in the evaluation of joint bone lesions.Results:The Kappa values (95%CI) of the consistency evaluation of fracture, hyperosteogeny, and bone destruction by CT and FRACTURE images were 0.925 (0.823-1.027), 0.905 (0.799-1.011) and 0.895(0.752-1.038) respectively for observer 1, and were 0.963 (0.892-1.034), 0.933 (0.843-1.023) and 0.886 (0.731-1.041) respectively for observer 2. The Kappa values (95%CI) of the consistency evaluation of fracture, hyperosteogeny, and bone destruction by observers 1 and 2 via CT images were 1.000 (1.000-1.000), 0.937(0.851-1.023) and 0.945 (0.839-1.051) respectively, and that by FRACTURE images were 0.962 (0.888-1.036), 0.966 (0.899-1.033) and 0.836 (0.656-1.016) respectively.Conclusion:For the evaluation of fracture, hyperosteogeny, and bone destruction of knee joint and ankle joint, MRI FRACTURE sequence is highly consistent with CT.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA