Rev. méd. Chile ; 148(4): 548-552, abr. 2020. graf
Artículo en Español | LILACS | ID: biblio-1127095

RESUMEN

Transcatheter aortic valve implantation (TAVI) has a lower perioperative risk than traditional surgery mostly when the transfemoral access is used. Some patients have anatomical conditions that contraindicate the use of this route. Lithoplasty is a novel technique that fractures calcium in coronary and peripheral arteries using pulsatile waves transmitted through an angioplasty balloon. We report an 83 year-old male with an aortic stenosis requiring TAVI, with severe calcification of his femoral and aortic arteries. A balloon lithoplasty of the right iliac-femoral tract was carried out, which allowed the use of the transfemoral route to install the aortic prosthesis. The patient had a good subsequent evolution.