1.
Braz. J. Anesth. (Impr.) ; 73(3): 340-343, May-June 2023. graf
Artículo en Inglés | LILACS | ID: biblio-1439616

RESUMEN

Abstract The prone position is extensively used to improve oxygenation in patients with severe acute respiratory distress syndrome caused by SARS-CoV-2 pneumonia. Occasionally, these patients exhibit cardiac and respiratory functions so severely compromised they cannot tolerate lying in the supine position, not even for the time required to insert a central venous catheter. The authors describe three cases of successful ultrasound-guided internal jugular vein cannulation in prone position. The alternative approach here described enables greater safety and well-being for the patient, reduces the number of episodes of decompensation, and risk of tracheal extubation and loss of in-situ vascular lines.


Asunto(s)
Humanos , Cateterismo Venoso Central , COVID-19/complicaciones , Posición Prona , Ultrasonografía Intervencional , COVID-19 , Unidades de Cuidados Intensivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA