Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Braz. dent. j ; 22(3): 218-222, 2011. ilus, tab
Artículo en Inglés | LILACS | ID: lil-595651

RESUMEN

This study used a mechanical test to evaluate the flexibility of instruments from the K3 (conicity 0.04) and the ProTaper Universal systems when they were new and after 5 uses in simulated canals. Five sets of instruments of each system were tested: K3 (15, 20, 25, 30, 35, 40 and 45) and ProTaper Universal (S1, S2, F1, F2, F3, F4 and F5). Each set of instruments was used to prepare a simulated canal and the same set of instruments was used 5 times (50 canals). The number of each subgroup represented the number of uses: 0 (control), 1, 3 and 5 uses. Before and after each use, the instruments were submitted to a mechanical flexibility test performed in a Versat 502 universal testing machine. Interactions between the instrument and the number of uses were analyzed by ANOVA and Tukey's test at a 5 percent level of significance. Instruments from both systems presented lower flexibility after the third use compared to the flexibility obtained after uses 0 and 1 (p<0.05), and maintained the same flexibility after the fifth use. The flexibility of instruments from the K3 system decreased with the increase of diameter, irrespective of the number of uses. Among the instruments from the ProTaper Universal system, the shaping files presented greater flexibility than the finishing files. F2 and F3 were the least flexible instruments, and F4 and F5 presented flexibility values similar to those of F1.


Esta pesquisa estudou a flexibilidade de instrumentos do Sistema K3 (conicidade 0.04) e do Sistema ProTaper Universal, por meio de um teste mecânico, quando os instrumentos eram novos e após 5 usos em canais simulados. Cinco jogos de instrumentos de cada sistema foram testados, como segue: grupo I - K3 (15, 20, 25, 30, 35, 40 e 45), e grupo II - ProTaper Universal (S1, S2, F1, F2, F3, F4 e F5). Cada jogo de instrumento foi usado para preparar um canal simulado, e o mesmo jogo de instrumento foi usado 5 vezes (50 canais). O número de cada subgrupo representou o número de usos: 0 (controle), 1, 3 e 5 usos. Antes do uso e depois de cada uso os instrumentos foram submetidos a um teste mecânico de flexibilidade realizado na máquina de ensaios universais Versat 502. A interação entre o instrumento e o número de usos foi analisada pelo ANOVA e pelo teste de Tukey ao nível de significância 5 por cento. Instrumentos de ambos os sistemas apresentaram menor flexibilidade após o terceiro uso quando comparada com a flexibilidade após os usos 0 e 1 (p<0,05), e mantiveram a mesma flexibilidade após o quinto uso. A flexibilidade dos instrumentos do sistema K3 diminuiu conforme o aumento de diâmetro, independente do número de usos. Entre os instrumentos do sistema ProTaper Universal, os shaping apresentaram maior flexibilidade que os finishing. F2 e F3 foram os menos flexíveis e F4 e F5 apresentaram valores de flexibilidade similares ao F1.


Asunto(s)
Humanos , Aleaciones Dentales/química , Níquel/química , Preparación del Conducto Radicular/instrumentación , Titanio/química , Cavidad Pulpar/anatomía & histología , Análisis del Estrés Dental/instrumentación , Módulo de Elasticidad , Resinas Epoxi , Equipo Reutilizado , Ensayo de Materiales , Modelos Anatómicos , Docilidad , Estrés Mecánico , Propiedades de Superficie
2.
Stomatos ; 15(29)jul.-dez. 2009.
Artículo en Portugués | LILACS | ID: lil-567130

RESUMEN

Este estudo teve como objetivo avaliar de forma qualitativa a expectativa e o aprendizado que o CEO tem proporcionado ao aluno de graduação em Odontologia da ULBRA. Para isso, foi realizado um questionário com seis perguntas abertas aos acadêmicos que estavam matriculados nesta disciplina curricular. Dos 43 alunos inscritos, 29 (67%) responderam as perguntas. Por meio da análise das respostas obtidas pode-se observar que este estágio curricular foi muito importante para o desenvolvimento crítico e profissional dos alunos participantes


This study aimed to evaluate of qualitative form the expectation and the training that the CEO has proportionate to the student of graduation in Dentistry of the ULBRA. For this, a questionnairewith six open questions to the academics was carried out to students who were registered in this curricular discipline. Of the 43 enrolled students 29 (67%) had answered the questions. By means of the analysis of the gotten answers it can be observed that this curricular period of training wasvery important for the development critic and professional of the participant students.


Asunto(s)
Evaluación Educacional , Investigación sobre Servicios de Salud , Curriculum , Universidades , Educación en Odontología , Especialidades Odontológicas , Estudios de Evaluación como Asunto , Educación en Salud , Servicios de Salud Dental
3.
Stomatos ; 15(29)jul.-dez. 2009.
Artículo en Portugués | LILACS | ID: lil-567131

RESUMEN

Analisou-se o desgaste no terço apical de canais simulados após instrumentação com o Sistema K3 de conicidade.04. Utilizaram-se 12 jogos de instrumentos do Sistema K3 e 12 canais simulados confeccionados com resina epóxi transparente. Os instrumentos foram empregados em canais com curvaturas de 20 e 40 graus. Os canais foram fotografados antes da instrumentação e após a utilização dos instrumentos que prepararam o batente apical: 30, 35, 40 e 45. As imagens foramsobrepostas no programa Adobe Photoshop CS2 versão 9.0 e mediu-se o desgaste, em milímetros, para fora da curva em dois locais: 1 (local A) e 5 (local B) milímetros aquém do comprimento de trabalho. Por meio da Análise de Variância estudou-se a existência de interação entre três fatores: curvatura do canal, calibre do instrumento e local da curva. Nos canais de 20º, em ambos os locais, a quantidade de desgaste promovido pelo instrumento de calibre 40 não diferiu significativamente do desgaste promovido pelo calibre 35. Nos canais de 40º, no local A, não houve diferença estatística entre o desgaste promovido pelos quatro diferentes calibres de instrumentos. Houve desvio, para o lado de fora da curva, em ambos os pontos analisados.


The authors analyzed the wear in apical third after K3 .04 System preparation. 12 sets of instruments were used and 12 simulated canals in transparent epoxy resin blocks with angles of curvature 20 and 40 degrees. Canals were photographed before preparation and after the utilization of instruments which prepared the apical stop: 30, 35, 40 e 45. The images were overposed inAdobe Photoshop program and the wear was measured in millimeters, in two points, 1 (A) and 5 (B) millimeters from the working length. By Variance Analysis the interaction existencewas studied among these three factors: canal curvature, instrument caliber and curve location. In canals of 20 degrees, in both analyzed points, the wear mean promoted by instrument 40 and instrument 35 there was not statistically signifi cant. In canals of 40 degrees, in location A, there was not statistically signifi cant difference in the wear mean promoted by four differentinstruments. There was a deviation from the original trajectory to the outside the curve, in both analyzed points.


Asunto(s)
Cavidad Pulpar , Endodoncia/instrumentación , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos
4.
J. appl. oral sci ; 17(5): 501-507, Sept.-Oct. 2009. ilus, tab
Artículo en Inglés | LILACS | ID: lil-531404

RESUMEN

OBJECTIVE: This study evaluated the wear in the apical third of simulate canals after preparation with ProTaper Universal Rotary System. MATERIAL AND METHODS: 24 sets of instruments were used in 24 simulated canals in transparent epoxy resin blocks with degree of curvature of either 20°or 40°. The canals were photographed preoperatively and after preparation of the apical stop with ProTaper F3, F4 and F5 instruments. The initial and final images were exported to Adobe Photoshop® software and superimposed to detect the root canal wall differences (in mm) between them, in two points located 1 (A) and 5 (B) mm from the point where the working length was established. Data were subjected to analysis of variance to verify the existence of interaction among the factors: canal curvature, instrument size and curve location. Significant level was set at 5 percent. RESULTS: Regardless of the location and the canal curvature, F4 and F5 instruments produced the greatest wear (p<0.05). CONCLUSIONS: There was a deviation from the original pathway towards the outside of the root curvature in both analyzed points. All instruments produced canal transportation, but the F4 and F5 instruments produced more than the other instruments, and should thus be used with care in curved canals.


Asunto(s)
Humanos , Cavidad Pulpar/anatomía & histología , Preparación del Conducto Radicular/instrumentación , Ápice del Diente/anatomía & histología , Aleaciones Dentales , Detergentes/uso terapéutico , Resinas Epoxi , Diseño de Equipo , Procesamiento de Imagen Asistido por Computador , Modelos Anatómicos , Irrigantes del Conducto Radicular/uso terapéutico , Preparación del Conducto Radicular/métodos , Programas Informáticos , Acero Inoxidable , Propiedades de Superficie , Dodecil Sulfato de Sodio/uso terapéutico
5.
RSBO (Impr.) ; 6(1)20/03/2009.
Artículo en Portugués | LILACS | ID: lil-509355

RESUMEN

Introdução e Objetivo: O presente estudo teve por objetivo avaliar e comparar as medidas do diâmetro D1 de cones estandardizados e secundários calibrados com régua calibradora através da medição do primeiro milímetro dos cones, com um paquímetro digital. Material e Métodos: utilizou-se dez cones de guta-percha estandardizados de cada calibre #25, #30, #35 e #40 das marcas Dentsply/Maillefer e Tanari, e cones secundários B8 calibrados por régua calibradora, perfazendo um total de 160 cones. Com o auxílio de um paquímetro digital eletrônico foi verificado o diâmetro a um milímetro da ponta do cone (D1). Resultados: obteve-se que em uma das marcas houve diferença significativa entre os cones padronizados e os calibrados. Quando comparado o calibre dos cones padronizados das duas marcas, também ocorreu diferença estatística, não ocorrendo quando os cones foram calibrados por régua calibradora. Conclusão: os cones Tanari, em média, tiveram um resultado superior aos cones calibrados e Dentsply, nessa ordem.


Introduction and Objective: The present study had for objective to evaluate and to compare the measures of the D1 diameter of calibrated standardized and secondary cones calibrated using a special scale through the measurement of the first millimeter of the cones, with one digital caliper. Material and Methods: Ten standardized gutta-percha cones of each type had been used: #25, #30, #35 and #40. The manufacturers were Dentsply/Maillefer and Tanari, and secondary cones B8 calibrated by a special scale, making a total of 160 cones. With the aid of a digital electronic caliper was verified the diameter to the one millimeter back from the tip of the cone (D1). Results: one of the manufacturers brand had significant difference between the standardized cones and the calibrated ones. When compared, the caliber of the standardized cones of both brands presented difference in statistics, not occurring when the cones had been calibrated by the special scale. Conclusion: the Tanari cones, on average, had a superior result compared to the calibrated cones and Dentsply, in this order.

6.
RSBO (Impr.) ; 6(1)20/03/2009.
Artículo en Portugués | LILACS | ID: lil-509358

RESUMEN

Introdução e Objetivo: O objetivo do presente estudo foi avaliar o padrão de estandardização dos tamanhos dos orifícios 35, 50 e 140 de três diferentes marcas comerciais de réguas calibradoras de cones de guta-percha e verificar possíveis distorções nos diâmetros 0,35; 0,50 e 1,40 mm após quatro ciclos de esterilização. Material e métodos: Foram fotografadas 10 réguas de cada uma das seguintes marcas comerciais: Angelus®, Maillefer® e Prisma®. Nove réguas (três de cada marca) foram submetidas a quatro ciclos de esterilização e fotografadas após cada um deles. Resultados e conclusão: Os resultados mostraram que houve variação nos diâmetros dos orifícios após as esterilizações, e que as três marcas apresentaram falta de fidelidade ao tamanho mencionado pelos fabricantes quando novas, isto é, sem esterilizações. A marca Maillefer®, antes de esterilizada, foi a que apresentou maior acurácia.


Introduction and Objective: The purpose of this study was to evaluate the standardization`s pattern of the holes of 3 different calibration rules trademarks for gutta-percha points and to verify possible distortions in the 0,35, 0,50 and 1,40mm diameters after four repeated cycles of sterilization. Material and methods: They were photographed 10 rules of each trademarks: Angelus®, Maillefer® and Prisma®. Nine rules (three of each brand) were subjected to 4 sterilization`s cycles and then photographed after each one. Results and conclusion: The results showed that there was variation in the holes`s diameter after the sterilization, and that the three brand new rules showed lack of loyalty to the size specified by the manufacturers. Maillefer® showed the greatest accuracy.

7.
RGO (Porto Alegre) ; 57(4): 381-384, out.-dez. 2009. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-873857

RESUMEN

Objective: This study evaluated the incidence of a fourth canal in the mesiobuccal root of maxillary first molars, investigating the importance of microscopic analysis of its trajectory in relation to the mesiobuccal canal. Methods: The analysis was performed of 65 randomly extracted maxillary first molars, with previous endodontic coronal opening, obtained from the Univille University tooth bank. The teeth were numbered and kept hydrated in distilled water. Compensatory wear was performed to widen the cavity in the mesiobuccal direction, foreseeing the presence of the mesiopalatal canal. A dental microscope was used to confirm presence of a groove (or ''fin'') and orifices in canals in the mesiobuccal root, and evaluate the presence of anastomosis between the root canals, following the modified method of Stropko1. Results: The incidence of the fourth canal (52.3%) was higher when microscopically observed, than clinically observed (29.3%). The results achieved by the modified method of Stropko1 demonstrated that most root canals (67.6%) presented union. Conclusion: There was higher incidence of the mesiopalatal canal (52.3%) observed in the microscopic analysis when compared with that observed in the clinical analysis (29.2%). The drying method allowed confirmation of union between canals in 67.6% of teeth. The combination of information achieved by radiographic examination of the trajectories of the mesiobuccal root and microscopic evaluation by the drying method allows the professional to gain better knowledge of the tooth under treatment, providing.


Objetivo: Este estudo avaliou a incidência do quarto canal em raízes mésio-vestibulares de primeiros molares superiores, investigando a importância da análise microscópica na sua trajetória em relação ao canal mésio-vestibular. Métodos: A análise foi executada em 65 primeiros molares superiores extraídos, que apresentavam abertura coronária prévia, obtidos no Banco de Dentes da Universidade Univille. Os dentes foram numerados, hidratados e conservados em água destilada. O desgaste compensatório foi executado ampliando a cavidade na direção MV, procurando a presença do canal mésio-palatino. Um microscópio clínico foi empregado para confirmar a presença de sulcos e a existência de orifícios nos locais correspondentes às entradas dos canais das raízes MV e para avaliar a presença de anastomoses entre os canais radiculares, através de uma modificação do método de Stropko1. Resultados: A incidência do quarto canal, com a observação microscópica (52,3%), foi maior do que a observada clinicamente (29,3%). Os resultados encontrados pela modificação do método de Stropko1 demonstraram que a maioria dos canais radiculares (67,6%) apresentou ligação entre si. Conclusão: A incidêncica do canal mésio-palatino (52,3%), observada na análise microscópica, foi alta, quando comparada com a análise clínica (29,2%). O método da secagem permitiu a confirmação da união dos canais em 67,6% dos dentes. A combinação das informações adquiridas pelo exame radiográfico das trajetórias das raízes MV e a avaliação microscópica pelo método da secagem permitiu ao profissional um melhor conhecimento dos dentes a serem tratados, tendo condições para alcançar melhores resultados.


Asunto(s)
Humanos , Cavidad Pulpar/anatomía & histología , Preparación del Conducto Radicular , Tratamiento del Conducto Radicular
8.
Rev. odontol. Univ. Cid. Sao Paulo ; 21(1)jan.-abr. 2009. graf, tab
Artículo en Portugués | LILACS-Express | LILACS | ID: lil-532083

RESUMEN

Introdução: Este estudo avalia, in vitro, a quantidade de desgaste produzido por instrumentos endodônticosde aço inoxidável, acionados a um sistema automatizado de movimento oscilatório, em três diferentesvelocidades: 6.000, 8.000 e 10.000 rotações por minuto. Métodos: Para isso, foram utilizadas 18 raízespalatinas de molares superiores, que foram distribuídas aleatoriamente em três grupos experimentais eindividualmente pesadas em uma balança digital analítica, antes e depois do preparo endodôntico. Resultadoe Conclusão: A comparação entre as médias de pesagem obtidas em cada grupo possibilitou concluirque não houve diferença estatística significativa quanto à quantidade de desgaste produzido entre as trêsvelocidades testadas


Introduction: This study evaluates, in vitro, the amount of produced consuming for stainless steel endodonticinstruments, defendant in an automatized system of oscillatory movement, in three different speeds:6.000, 8.000 and 10.000 rotations per minute. Methods: For this, 18 palatines root canals of superior molarsuperiors had been used, that had been randomly distributed in three individually weights in experimentalgroups and in an analytical digital scale before and after the endodontic preparation. Result and Conclusion:The comparison between the averages of weight in each group made possible to conclude that there were nosignificant statistical difference to the amount of consuming produced among of the three tested speeds

9.
RSBO (Impr.) ; 5(2): 69-74, ago. 2008. ilus
Artículo en Portugués | LILACS | ID: lil-489550

RESUMEN

Introdução: A cirurgia paraendodôntica é um procedimento que tem como finalidade resolver problemas que não puderam ser solucionados pelo tratamento endodôntico convencional, ou quando este não é possível. Relato do caso e conclusão: Neste trabalho há o relato de um caso clínico de dentes portadores de coroas protéticas com pinos intra-radiculares, em que se optou pela realização do procedimento cirúrgico. Foram efetuadas apicectomia e retroobturação com MTA no dente 11, apicectomia no dente 21 e apicectomia, retroinstrumentação e retrobturação com MTA no dente 22.


Introduction: Paraendodontic surgery is a procedure that aims problems resolution that couldn’t be solved by the conventional endodontic treatment, or when the accomplishment conventional treatment is not possible. Case report and conclusion: The aim of this study was to report a clinical case where was made apicectomy on the teeth 11, 21 and 22. The tooth 22 was sealing of root-end cavity MTA retrofilling.

10.
RSBO (Impr.) ; 5(1): 34-41, abr. 2008. ilus
Artículo en Portugués | LILACS-Express | LILACS | ID: lil-482746

RESUMEN

Introdução e objetivo: Em função de a dissolução tecidual ser um fator relevante para o saneamento dos canais radiculares, este estudo avaliou a capacidade do ácido tricloroisocianúrico nas concentrações de 1%, 2%, 3% e 4% de dissolver tecido pulpar bovino comparativamente ao hipoclorito de sódio 1%. Material e métodos: Utilizaram-se seis polpas de incisivos inferiores bovinos com média de 13 mm de comprimento. As polpas foram colocadas em copos de Becker de 20 mL que continham 10 mL das soluções testadas. Foram utilizadoso hipoclorito de sódio 1% como controle positivo e a água destilada como controle negativo. Resultados e conclusão: Em 2 horas e 29 minutos obteve-se dissolução total do tecido pulpar com a utilização do NaOCl 1%, e nenhuma dissolução foi verificada com a água destilada. Em um tempo de 12 horas de observação o ácido tricloroisocianúrico não foi capaz de dissolver a totalidade de tecido. Os resultados em 12 horas de observação foram: ácido tricloroisocianúrico 1% dissolveu 47%, ácido tricloroisocianúrico 2% dissolveu 54%, ácido tricloroisocianúrico 3% dissolveu 62% e ácido tricloroisocianúrico 4% dissolveu 77% de tecido pulpar. Em relação ao ácido tricloroisocianúrico, mais pesquisas devem ser realizadas, levando em consideração, além do tempo para dissolução do tecido pulpar, os efeitos que esse ácido exerce nos tecidos periapicais.


Introduction and objective: Due to tissue dissolution being a relevant factor to the root canals´ sanitation, this study avaliated the dissolution capacity of bovine´s pulp tissue by trichloroisocyanuric acid at 1%, 2%, 3% and 4% concentrations in comparison to sodium hypochlorite 1%. Materials and methods: The authors utilized six bovine´s inferior incisors pulps with approximately 13 millimeters length. The pulps were immersed in 10 milliliters testing solutions. The sodium hypochlorite 1% was used as negative control and distilled water as positive control. Results and conclusion: In 2 hours and 29 minutes total dissolution of the pulp tissue was obtained with the NaOCl 1%, and no dissolution was verified with the distilled water. Within twelve hours, the trichloroisocyanuric was not able to dissolve the tissue totality. The results within twelve hours of observation were: trichloroisocyanuric acid 1% dissolved 47%, trichloroisocyanuric acid 2% dissolved 54%, trichloroisocyanuric acid 3% dissolved 62% and trichloroisocyanuric acid 4% dissolved 77% of bovine´s pulp tissue. In relation to trichloroisocyanuric acid, more researchs must be done, considering, besides the time to the pulp tissue dissolution, the efects that the trichloroisocyanuric acid has on the periapicals tissues.

11.
Stomatos ; 13(24): 11-20, jan.-jun. 2007. tab, graf
Artículo en Portugués | LILACS, BBO | ID: lil-542156

RESUMEN

A proposta deste estudo foi mensurar a tensão superficial de diferentes substâncias utilizadas na terapia endodôntica através do método da ascensão capilar. Para a realização deste experimento, foi utilizado um tubo capilar de vidro com diâmetro interno de 0,5 mm e20 cm de comprimento que propiciava a ascensão dos líquidos após imersão em um volume fixo das soluções testes. Posteriormente, aspiraram-se tais líquidos, aguardando sua estabilização no interior do capilar, sendo então determinada a coluna líquida do capilar. Como resultado obtiveram-se as seguintes tensões superficiais, em ordem decrescente: NaOCl 1%(60,7 dinas/cm), tricresol formalina (27,2 dinas/cm), PMCC (25,5 dinas/cm). Também severificou a hipótese de reduzir a tensão superficial em soluções de EDTA, quando da adição de doses crescentes de detergente, onde se obteve os seguintes resultados: EDTA 17% +0,1% de tergentol (45,60 dinas/cm), EDTA 17% + 0,5% de tergentol (45,69 dinas/cm), EDTA17% + 1% de tergentol (28,34 dinas/cm), EDTA 17% + 5% de tergentol (24,58 dinas/cm),EDTA 17% + 10% de tergentol (17,68 dinas/cm).


This research purpose measure the surface tension’s substances used in endodontic therapy by means of creeping. The authors used a tube glass capillary with inside diameter 0,5 millimeter and length 20 centimeter. The tube propitiate the liquid’s ascension. Liquids were aspirated and after stabilization into the tube glass capillary was measured the capilar’s liquid column. The surface tension’s result were: sodium hypochlorite 1% (60,7 dynes/c), tricresol formalin(27,2 dynes/c), PMCC (25,5 dynes/c). Besides the authors testify the hypothesis the surface tension’s reduction of EDTA solutions when increased cleanser’s crescent doses. The findingswere: EDTA 17%+0,1% tergentol (45,60 dynes/c); EDTA 17%+0,5% tergentol (45,69 dynes/c); EDTA 17%+1% tergentol (28,34 dynes/c); EDTA 17%+5% tergentol (24,58% dynes/c) eEDTA 17%+10% tergentol (17,68 dynes/c).


Asunto(s)
Compuestos Químicos , Endodoncia , Tensión Superficial
12.
RSBO (Impr.) ; 4(1): 17-21, maio 2007. ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-873538

RESUMEN

A finalidade deste trabalho foi relatar um caso clínico em que ocorreu a injeção acidental na região periapical da solução irrigadora de hipoclorito de sódio 2,5% durante tratamento endodôntico de um primeiro molar superior. Os autores demonstraram, por meio da descrição deste caso clínico, que soluções concentradas de hipoclorito de sódio, quando extrudadas inadvertidamente para a região periapical, causam danos teciduais, desconforto para o paciente e, consequentemente, dúvidas quanto à habilidade do cirurgião-dentista


The authors' aim was to report a clinical case of accidental injection of sodium hypochlorite 2,5% into periapical region during the root canal treatment of the upper right first molar. It was demonstrated that sodium hypochlorite concentrate solutions injection induces tissular injuries, discomfort for the patient and doubts about the dentist's ability


Asunto(s)
Humanos , Masculino , Dolor , Tejido Periapical , Edema , Hipoclorito de Sodio , Irrigantes del Conducto Radicular
13.
RSBO (Impr.) ; 4(1): 29-36, maio 2007. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: biblio-873540

RESUMEN

Foram analisados o teor de cloro ativo e o pH em amostras da solução de hipoclorito de sódio a 1%, provenientes de 3 diferentes frascos onde estavam armazenadas (frasco Pet 1, Pet 2 e Pet 3). Uma amostra de cada frasco foi colhida imediatamente no momento da abertura das embalagens (tempo 0:T), e as outras três (uma de cada frasco) foram deixadas expostas a luz e temperatura ambiente por aproximadamente 3 horas e posteriormente levadas para análise (tempo 1:T1). Conclui-se que em todas as amostras houve diminuição do teor de cloro ativo de T0 para T1. Apenas nas amostras provenientes do primeiro frasco (Pet 1) o pH baixou de 12,00 para 11,50(de T0 para T1). A porcentagem de teor de cloro ativo não condizia com o descrito no rótulo nas amostras provenientes dos três frascos Pet


Asunto(s)
Cloro , Hipoclorito de Sodio
14.
Braz. dent. j ; 18(4): 289-293, 2007.
Artículo en Inglés | LILACS | ID: lil-474466

RESUMEN

This in vitro study compared, using computed tomography (CT), the amount of dentin removed from root canal walls by manual and mechanical rotary instrumentation techniques. Forty mandibular incisors with dental crown and a single canal were selected. The teeth were randomly assigned to two groups, according to the technique used for root canal preparation: Group I - manual instrumentation with stainless steel files; Group II - mechanical instrumentation with RaCe rotary nickel-titanium instruments. In each tooth, root dentin thickness of the buccal, lingual, mesial and distal surfaces in the apical, middle and cervical thirds of the canal was measured (in mm) using a multislice CT scanner (Siemens Emotion, Duo). Data were stored in the SPSS v. 11.5 and SigmaPlot 2001 v. 7.101 softwares. After crown opening, working length was determined, root canals were instrumented and new CT scans were taken for assessment of root dentin thickness. Pre- and post-instrumentation data were compared and analyzed statistically by ANOVA and Tukey's post-hoc test for significant differences (p=0.05). Based on the findings of this study, it may be concluded that regarding dentin removal from root canal walls during instrumentation, neither of the techniques can be considered more effective than the other.


Este estudo in vitro avaliou comparativamente, por meio de tomografia computadorizada (TC), a quantidade de dentina removida das paredes do canal radicular utilizando-se as técnicas de preparo manual e automatizada de instrumentação rotatória. Foram selecionados 40 incisivos inferiores com coroa dental e um único canal. Os dentes foram divididos aleatoriamente em 2 grupos, de acordo com a técnica empregada para o preparo dos canais radiculares: Grupo I - técnica manual com limas manuais de aço inoxidável e Grupo II - técnica automatizada de movimentos rotatórios RaCe com limas de níquel-titânio. Em cada dente, procedeu-se à mensuração (em mm) da espessura da dentina radicular nas faces vestibular, lingual, mesial e distal dos terços apical, médio e cervical por meio de tomografia computadorizada multislice (Siemens Emotion, Duo). Os dados coletados foram armazenados utilizando-se os softwares SPSS versão 11.5 e SigmaPlot 2001 v. 7.101 (SPSS Inc.). Após a abertura coronária, o comprimento de trabalho foi estabelecido, os canais radiculares foram instrumentados e novas tomadas de tomografia computadorizada foram realizadas para mensuração da espessura das paredes dentinárias radiculares. Os dados obtidos antes e após o preparo biomecânico dos canais foram comparados. Os resultados foram estatisticamente por meio de análise de variância (ANOVA) com localização de diferenças post hoc de Tukey (p=0,05). Com base nos achados desse estudo, pode-se concluir que: com relação à remoção de dentina das paredes dos canais radiculares durante a instrumentação nenhuma das técnicas avaliadas pode ser apontada como mais efetiva que a outra.


Asunto(s)
Humanos , Cavidad Pulpar , Preparación del Conducto Radicular/instrumentación , Tomografía Computarizada por Rayos X , Aleaciones Dentales , Dentina , Diseño de Equipo , Ensayo de Materiales , Níquel , Acero Inoxidable , Titanio , Ápice del Diente , Cuello del Diente
15.
RSBO (Impr.) ; 3(2): 37-43, nov. 2006.
Artículo en Portugués | LILACS, BBO | ID: biblio-873532

RESUMEN

O objetivo deste trabalho foi realizar uma revisão bibliográfica sobre a histomorfologia do reparo de dentes com rizogênese incompleta que receberam tratamento endodôntico. Embora o mecanismo histológico do reparo ainda permaneça relativamente obscuro e sua explicação encontre controvérsia na literatura, há o consenso de que a barreira de tecido duro apical pode ser formada por dentina ou cemento, em dependência das células que estiverem presentes no momento da intervenção. A morfologia do reparo da região apical tem sido estudada e caracterizada de duas formas: pelo aparecimento de substância radiopaca que obstrui a abertura apical simplesmente ou pela complementação do desenvolvimento radicular com deposição de tecido duro apical, podendo a raiz do elemento dentário apresentar diversas configurações. O hidróxido de cálcio continua sendo o material mais requisitado nesse tipo de tratamento, mesmo que alguns pesquisadores sustentem que o fechamento apical ocorra quando controlada a infecção e sem a utilização de um material indutor de tecido mineralizado


This bibliographical research has investigated the healing process after root canal therapy in immature human teeth. Although there is still uncertainty about the histological mechanism of the treatment and there is a controversial explanation in literature, the authors asseverate that the apical limit can be formed by two tissues: dentine or cementum. The healing process has been studied and characterized by the appearance of radiopaque tissue on the apical region or by the complementation of radicular development with hard apical tissue deposition. In this case the root of the teeth may present several forms. The most commonly used substance in the treatment is calcium hydroxide. Some researchers say that the apical closure may occur when the infection is controlled and in the absence of an inductive substance of mineralized tissue


Asunto(s)
Humanos , Diente , Hidróxido de Calcio , Apexificación , Endodoncia Regenerativa
16.
RSBO (Impr.) ; 3(2): 26-31, nov. 2006. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-873530

RESUMEN

O objetivo deste estudo foi determinar a qualidade de remoção do sistema Thermafill durante o retratamento endodôntico com a utilização do sistema ProFile .04 em duas diferentes velocidades. Trinta caninos com raízes únicas foram preparados pela técnica coroa-ápice e obturados com um carregador número 40 do sistema Thermafill, sendo utilizado como cimento obturador o Ah-plus. Duas semanas após as obturações, a remoção do material obturador foi iniciada da seguinte forma: GRUPO I-sistema ProFile .04 na sequência 90,60,45,40,45, sem solvente e na velocidade de 350 rpm; GRUPO II-a mesma técnica, porém em 2.000 rpm. Os espécimes foram então seccionados longitudinalmente e escaneados para a análise por intermédio de um software específico (ImageTool), o qual mediu a área de remanescentes obturadores, assim como a presença do carregador plástico do Thermafill. A média de remanescentes de material obturador foi de 24,86% para o Grupo I e 24,91% para o Grupo II, e após a aplicação do teste T-student verificou-se que não houve diferença estatisticamente significante entre os grupos estudados, havendo a remoção dos carregadores plásticos do Thermafill em todos os espécimes. Conclui-se que a qualidade de remoção do material obturador foi similar para ambas as velocidades empregadas e que os carregadores plásticos foram removidos com sucesso pelo sistema ProFile .04


This study aimed at determining the quality of removal of the thermafill systemin endodontic retreatment with utilization of the 0.04 ProFile system at twodifferent speeds. Thirty single-rooted mandibular canines were divided intotwo groups. The canals were prepared with the crown-down technique andobturated with the thermafill system with a carrier #40 and Ah-plus sealer.Fillings were removed two weeks after obturation, as follows: Group I ­ 0.04ProFile following the size sequence 90, 60, 45, 40 and 45, without solvent, ata speed of 350rpm; Group II ­ same technique at 2000rpm. The specimenswere longitudinally sectioned and were scanned and analyzed by a software(ImageTool) that measured the area of remaining filling material and removalof the plastic carrier. The mean of remnants of filling material was 24.86% at Group I, 24.91% at Group II and the area was not statistically different(Student's "t" test) between the two groups and all plastic carriers wereremoved. It was concluded that the quality of removal of the filling materialat both speeds (350 or 2000rpm) was similar; and all plastic carrierswere removed with success by ProFile .04 system


Asunto(s)
Materiales de Obturación del Conducto Radicular , Retratamiento , Diente Canino , Cementos Dentales , Gutapercha
17.
RSBO (Impr.) ; 3(2)nov. 2006. ilus, tab
Artículo en Inglés | LILACS | ID: lil-482780

RESUMEN

This study aimed at determining the quality of removal of the thermafill systemin endodontic retreatment with utilization of the 0.04 ProFile system at two different speeds. Thirty single-rooted mandibular canines were divided into two groups. The canals were prepared with the crown-down technique and obturated with the thermafill system with a carrier #40 and Ah-plus sealer. Fillings were removed two weeks after obturation, as follows: Group I - 0.04 ProFile following the size sequence 90, 60, 45, 40 and 45, without solvent, at a speed of 350rpm; Group II - same technique at 2000rpm. The specimens were longitudinally sectioned and were scanned and analyzed by a software (ImageTool) that measured the area of remaining filling material and removal of the plastic carrier. The mean of remnants of filling material was 24.86% at Group I, 24.91% at Group II and the area was not statistically different (Student- test) between the two groups and all plastic carriers wereremoved. It was concluded that the quality of removal of the filling material at both speeds (350 or 2000rpm) was similar; and all plastic carriers were removed with success by ProFile .04 system.


O objetivo deste estudo foi determinar a qualidade de remoção do sistemaThermafill durante o retratamento endodôntico com a utilização do sistemaProFile .04 em duas diferentes velocidades. Trinta caninos com raízes únicas foram preparados pela técnica coroa-ápice e obturados com um carregador número 40 do sistema Thermafill, sendo utilizado como cimento obturadoro Ah-plus. Duas semanas após as obturações, a remoção do material obturador foi iniciada da seguinte forma: GRUPO I - sistema ProFile .04 na seqüência 90, 60, 45, 40, 45, sem solvente e na velocidade de 350 rpm; GRUPO II - a mesma técnica, porém em 2.000 rpm. Os espécimes foramentão seccionados longitudinalmente e escaneados para a análise por intermédio de um software específico (ImageTool), o qual mediu a área de remanescentes obturadores, assim como a presença do carregador plástico do Thermafill. A média de remanescentes de material obturador foi de 24,86% para o Grupo I e 24,91% para o Grupo II, e após a aplicação do teste T-student verificou-se que não houve diferença estatisticamente significante entre os grupos estudados, havendo a remoção dos carregadores plásticos do Thermafill em todos os espécimes. Conclui-se que a qualidade de remoção do material obturador foi similar para ambas as velocidades empregadas e que os carregadores plásticos foram removidos com sucesso pelo sistema ProFile .04.


Asunto(s)
Endodoncia , Gutapercha
18.
Rev. ABO nac ; 14(4): 237-241, ago.-set. 2006. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-544738

RESUMEN

Introdução - A capacidade solvente do hipoclorito de sódio tem sido bastante abordada atualmente. O presente trabalho testou o poder solvente de cinco concentrações diferentes de hipoclorito de sódio utilizadas em Endodontia. Material e Métodos - Foram empregadas soluções comercializadas, prontas para uso, líquido de dakin, solução de Milton, soda clorada, água sanitária Brilux e soda clorada duplamente concentrada; e soluções de hipoclorito de sódio manipuladas em farmácia nas mesmas concentrações das soluções prontas. Foram divididos em dois grupos experimentais, com 25 amostras em cada grupo: G1-comerciais, G2-manipuladas, cada grupo dividido em cinco subgrupos, cada subgrupo cinco amostras. Cinqüenta fragmentos de língua de rato foram submetidos à ação solvente das soluções de hipoclorito de sódio. O tempo de dissolução foi cronometrado. Resultados - A análise estatística revelou não haver diferença estatisticamente significante no poder solvente nos grupos de mesma concentração em: 2,0%; 2,5% e 5,0%, enquanto em: 0,5% e 1,0% há uma diferença significante entre as soluções comercial e manipulada. Conclusões - As soluções de hipoclorito de sódio quando manipuladas são mais eficientes dissolventes do tecido orgânico, obedecendo a uma relação diretamente proporcional a concentração do teor de cloro ativo da solução.


Introduction - The solvent capacity of the sodium hypochlorite has been sufficiently boarded currently. The present work tested the solvent power of five different concentrations of sodium hypochlorite used in Endodontics. Material and Methods - Commercialized solutions had been used, ready for use, liquid of Dakin, solution of Milton, chlorinated soda water, sanitary water Brilux and doubly intent chlorinated soda; e solutions of sodium hypochlorite manipulated in pharmacy in the same concentrations of the ready solutions. They had been divided in two experimental groups, with 25 samples in each group: G1-commercial, G2- manipulated, each group divided in five sub-groups, each sub-group five samples. Fifty fragments of rat language had been submitted to the solvent action of the solutions of sodium hypochlorite. The dissolution time was chronometered. Results - The analysis statistics disclosed not to have significant difference in the solvent power in the groups of same concentration in: 2, 0%; 2, 5% and 5.0%, while in: 0,5% and 1.0% have a significant difference between the solutions manufactured and manipulated. Conclusions - The solutions of sodium hypochlorite when manipulated they are more efficient quick solving of the fabric organic, obeying a directly proportional relation the concentration of the active chlorine text of the solution.


Asunto(s)
Animales , Ratas , Disolución , Endodoncia , Hipoclorito de Sodio/efectos adversos , Irrigantes del Conducto Radicular , Solventes
19.
Rev. Fac. Odontol. Porto Alegre ; 47(2): 9-13, ago. 2006. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-466379

RESUMEN

A instrumentação dos canais radiculares é uma das etapas mais importantes da terapia endodôntica. Este estudo realizou uma análise comparativa do desgaste promovido nas paredes mesial e distal do canal mésio-vestibular de molares superiores, terços cervical e médio, pela associação das brocas Gates Glidden (Dentsply Maillefer, Ballaigues, Switzerland) com limas manuais e pelo sistema automatizado K3 (SybronEndo, CA, USA). A amostra consistiu em vinte raízes que foram, primeiramente, incluídas em uma modificação da mufla proposta por Bramante et al (1987). Após a inclusão, as mesmas foram seccionadas transversalmente em duas superfícies de observação, 1mm além do orifício de entrada do canal e lmm aquém do início da curvatura. O preparo cervical de dez raízes foi realizado com as brocas Gates Glidden números 1 e 2, sendo a instrumentação concluída com limas manuais. As outras dez raízes tiveram seus condutos preparados pelo sistema K3. As espessuras de dentina das paredes analisadas foram medidas antes e após os preparos através do uso de um microscópio metalográfico (Union), com ocular graduada, no aumento de 50x. Os resultados demonstraram valores médios de desgaste nas paredes analisadas maiores nos preparos realizados com a associação das brocas Gates Glidden e limas manuais. Somente na parede distal lmm da entrada do canal o sistema K3 apresentou o valor médio pouco superior. Os dados foram submetidos ao Teste t de Student para amostras não pareadas, não apresentando diferenças estatisticamente significantes.Concluiu-se através deste trabalho, que as técnicas de preparo apresentam um desempenho semelhante quanto ao desgaste radicular dos terços cervical e médio.


Asunto(s)
Humanos , Técnicas In Vitro , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos
20.
RSBO (Impr.) ; 3(1): 35-40, maio 2006.
Artículo en Portugués | LILACS, BBO | ID: biblio-873521

RESUMEN

A anestesia local corresponde ao bloqueio reversível da condução nervosa e determina perda das sensações sem alteração do nível de consciência. A maioria dos profissionais de Odontologia elege somente uma solução anestésica local para todos os procedimentos que executa. A padronização de uma solução para uso geral nem sempre satisfaz às necessidades clínicas e ao bem-estar dos pacientes. Em razão disso, visando auxiliar o odontologista na escolha da solução anestésica ­ com base na revisão de literatura ­, foi proposta deste trabalho apresentar os anestésicos locais injetáveis adequados para os diferentes procedimentos operatórios e de acordo com as diversas condições sistêmicas dos pacientes. Sugere-se que o profissional tenha no consultório mais de um tipo de solução anestésica local com vasoconstritor e uma solução sem essa substância


The local anesthesia is the reversible blockade of the nervous impulse that induces the sensations' loss without changing the conscience level. Most of dentists choose only one local anesthetics for all clinic procedures. The standardization of the same solution anesthetics for all procedures does not always satisfy the clinical needs and the patients' well being. Because of this, based on the literature review, the aim of this study was to present the adequate local anesthetics for different clinical procedures and the several patients' systemic situations. Our suggestion for the dentist is to keep in his office more than one local anesthetics with vasoconstrictors and at least one solution without vasoconstrictors


Asunto(s)
Vasoconstrictores , Clínicas Odontológicas , Odontólogos , Anestesia Local , Anestesia Dental , Pacientes , Métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA