Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Braz. j. otorhinolaryngol. (Impr.) ; 89(3): 462-468, May-June 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1447705

RESUMEN

Abstract Objectives To determine whether tinnitus negatively impacts the accuracy of sound source localization in participants with normal hearing. Methods Seventy-five participants with tinnitus and 74 without tinnitus were enrolled in this study. The accuracy of sound source discrimination on the horizontal plane was compared between the two participant groups. The test equipment consisted of 37 loudspeakers arranged in a 180° arc facing forward with 5° intervals between them. The stimuli were pure tones of 0.25, 0.5, 1, 2, 4, and 8 kHz at 50 dB SPL. The stimuli were divided into three groups: low frequency (LF: 0.25, 0.5, and 1 kHz), 2 kHz, and high frequency (HF: 4 and 8 kHz) stimuli. Results The Root Mean Square Error (RMSE) score of all the stimuli in the tinnitus group was significantly higher than that in the control group (13.45 ± 3.34 vs. 11.44 ± 2.56, p = 4.115, t < 0.001). The RMSE scores at LF, 2 kHz, and HF were significantly higher in the tinnitus group than those in the control group (LF: 11.66 ± 3.62 vs. 10.04 ± 3.13, t = 2.918, p = 0.004; 2 kHz: 16.63 ± 5.45 vs. 14.43 ± 4.52, t = 2.690, p = 0.008; HF: 13.42 ± 4.74 vs. 11.14 ± 3.68, t = 3.292, p = 0.001). Thus, the accuracy of sound source discrimination in participants with tinnitus was significantly worse than that in those without tinnitus, despite the stimuli frequency. There was no difference in the ability to localize the sound of the matched frequency and other frequencies (12.86 ± 6.29 vs. 13.87 ± 3.14, t = 1.204, p = 0.236). Additionally, there was no correlation observed between the loudness of tinnitus and RMSE scores (r = 0.096, p = 0.434), and the Tinnitus Handicap Inventory (THI) and RMSE scores (r = −0.056, p = 0.648). Conclusions Our present data suggest that tinnitus negatively impacted sound source localization accuracy, even when participants had normal hearing. The matched pitch and loudness and the impact of tinnitus on patients' daily lives were not related to the sound source localization ability. Level of evidence 4.

2.
Braz. j. med. biol. res ; 51(6): e6452, 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-889104

RESUMEN

Several microRNAs (miRNAs) have been reported as oncogenes or tumor suppressors in many cancers, including gastric cancer (GC). However, the role and molecular mechanism of miR-3129 in GC is largely unknown. We aimed to explore the function and the underlying molecular mechanism of miR-3129 in GC. Cancer tissues and corresponding adjacent tissues were collected from 50 patients with GC, and the expression of miR-3129 was detected by RT-qPCR. The expression of miR-3129 and pRb in human GC cell line SCG7091 was altered by transient transfection. Thereafter, MTT and flow cytometry assays were used to analyze cell viability and cell cycle. The expression of cyclin E, CDK2, CDK2 inhibitors (p16 and 21), and pRb were detected by RT-qPCR and western blot. A significant up-regulation of miR-3129 was observed in GC tissues compared to adjacent tissues. Overexpression of miR-3129 significantly improved cell viability after 4 days of post-transfection. Flow cytometry assay results showed that the miR-3129 overexpression arrested more SGC7901 cells at S phase. Moreover, overexpression of miR-3129 down-regulated the expression of CDK2 inhibitors while it up-regulated the expression levels of cyclin E, CDK2, and pRb. Interestingly, we found that pRb inhibition reversed the effect of miR-3129 inhibitor on cell proliferation in SGC7901 cells, increased cell viability, reduced cells at G0/1 phase, and modulated the expression of proliferation-related factors. Our results revealed that miR-3129 functioned as an oncogene through positive regulation of pRb and may prove to be a promising option for molecular therapy of GC.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Proliferación Celular/genética , Proteína de Retinoblastoma/genética , Neoplasias Gástricas/genética , Línea Celular Tumoral , Supervivencia Celular , Regulación hacia Abajo , Citometría de Flujo , Regulación Neoplásica de la Expresión Génica/genética , Estadificación de Neoplasias , Reacción en Cadena en Tiempo Real de la Polimerasa , Proteína de Retinoblastoma/metabolismo , Transducción de Señal , Neoplasias Gástricas/metabolismo , Neoplasias Gástricas/patología , Transfección , Regulación hacia Arriba
3.
Chinese Medical Equipment Journal ; (6): 31-33, 2017.
Artículo en Chino | WPRIM | ID: wpr-662460

RESUMEN

Objective To develop an auxiliary device to facilitate the ultrasound probe to position in vivo foreign body.Methods The auxiliary device was composed of a support plate,a locating needle tube and an elastic rubber sleeve.The support plate was rectangular and had a radian structure;the locating needle tube was fixed at lateral middle part of the plate to accommodate the needle;the elastic rubber sleeve was hollow and held the plate and needle tube after expansion.Results The device gained advantages in convenience,promptness and stability,and enhanced the accuracy and success rate of in vivo foreign body positioning by the ultrasound probe.Conclusion The device has simple structure,easy manufacture and low cost,and thus is worthy promoting clinically.

4.
Chinese Medical Equipment Journal ; (6): 31-33, 2017.
Artículo en Chino | WPRIM | ID: wpr-660085

RESUMEN

Objective To develop an auxiliary device to facilitate the ultrasound probe to position in vivo foreign body.Methods The auxiliary device was composed of a support plate,a locating needle tube and an elastic rubber sleeve.The support plate was rectangular and had a radian structure;the locating needle tube was fixed at lateral middle part of the plate to accommodate the needle;the elastic rubber sleeve was hollow and held the plate and needle tube after expansion.Results The device gained advantages in convenience,promptness and stability,and enhanced the accuracy and success rate of in vivo foreign body positioning by the ultrasound probe.Conclusion The device has simple structure,easy manufacture and low cost,and thus is worthy promoting clinically.

5.
Braz. j. microbiol ; 44(3): 949-952, July-Sept. 2013.
Artículo en Inglés | LILACS, VETINDEX | ID: biblio-1469599

RESUMEN

It is well known that the type III secretion system (T3SS) and type III (T3) effectors are essential for the pathogenicity of most bacterial phytopathogens and that the expression of T3SS and T3 effectors is suppressed in rich media but induced in minimal media and plants. To facilitate in-depth studies on T3SS and T3 effectors, it is crucial to establish a medium for T3 effector expression and secretion. Xanthomonas campestris pv. campestris (Xcc) is a model bacterium for studying plant-pathogen interactions. To date no medium for Xcc T3 effector secretion has been defined. Here, we compared four minimal media (MME, MMX, XVM2, and XOM2) which are reported for T3 expression induction in Xanthomonas spp. and found that MME is most efficient for expression and secretion of Xcc T3 effectors. By optimization of carbon and nitrogen sources and pH value based on MME, we established XCM1 medium, which is about 3 times stronger than MME for Xcc T3 effectors secretion. We further optimized the concentration of phosphate, calcium, and magnesium in XCM1 and found that XCM1 with a lower concentration of magnesium (renamed as XCM2) is about 10 times as efficient as XCM1 (meanwhile, about 30 times stronger than MME). Thus, we established an inducing medium XCM2 which is preferred for T3 effector secretion in Xcc.


Asunto(s)
Receptores de Hormona Tiroidea , Western Blotting , Xanthomonas campestris , Glucuronidasa , Triyodotironina
6.
Braz. j. microbiol ; 44(3): 945-952, July-Sept. 2013. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-699825

RESUMEN

It is well known that the type III secretion system (T3SS) and type III (T3) effectors are essential for the pathogenicity of most bacterial phytopathogens and that the expression of T3SS and T3 effectors is suppressed in rich media but induced in minimal media and plants. To facilitate in-depth studies on T3SS and T3 effectors, it is crucial to establish a medium for T3 effector expression and secretion. Xanthomonas campestris pv. campestris (Xcc) is a model bacterium for studying plant-pathogen interactions. To date no medium for Xcc T3 effector secretion has been defined. Here, we compared four minimal media (MME, MMX, XVM2, and XOM2) which are reported for T3 expression induction in Xanthomonas spp. and found that MME is most efficient for expression and secretion of Xcc T3 effectors. By optimization of carbon and nitrogen sources and pH value based on MME, we established XCM1 medium, which is about 3 times stronger than MME for Xcc T3 effectors secretion. We further optimized the concentration of phosphate, calcium, and magnesium in XCM1 and found that XCM1 with a lower concentration of magnesium (renamed as XCM2) is about 10 times as efficient as XCM1 (meanwhile, about 30 times stronger than MME). Thus, we established an inducing medium XCM2 which is preferred for T3 effector secretion in Xcc.


Asunto(s)
Sistemas de Secreción Bacterianos , Proteínas Bacterianas , Medios de Cultivo/química , Factores de Virulencia/metabolismo , Xanthomonas campestris/crecimiento & desarrollo , Xanthomonas campestris/metabolismo
7.
Saudi Medical Journal. 2013; 34 (4): 428-431
en Inglés | IMEMR | ID: emr-193845
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA