Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Blood Transfusion ; (12): 467-470, 2023.
Artículo en Chino | WPRIM | ID: wpr-1004807

RESUMEN

【Objective】 To analyze differences of eplets between the patient who generated HLA allele-specific antibodies after platelet transfusion with donors. 【Methods】 The HLA genotypes of the patient and donors were detected by PCR-SBT, and the Luminex single antigen beads coating was used to screen HLA-Ⅰ antibodies in the patient’s serum. HLA Matchmaker was utilized to analyze different amino acids and eplets. 【Results】 The patient carried HLA-A*02∶03 allele, and HLA-A2 antibodies were found in his serum after platelet transfusion (A*02∶01, A*02∶06, and A*02∶07). Sequence alignment showed that the patient′s A*02∶03 has a difference in position 149, which resulted in a different eplet between A*02∶03 and A*02∶01, A*02∶06, A*02∶07 and then induced the production of antibodies. 【Conclusion】 HLA antibodies are specific for HLA epitopes that have structural differences due to amino acid differences between HLA alleles, suggesting that high-resolution typing of HLA-A, -B need to be conducted in patients and donors, and the acceptable mismatch of HLA should be determined based on epitopes rather than antigens, so as to reduce alloimmune response and improve platelet count after transfusion.

2.
Chinese Journal of Blood Transfusion ; (12): 622-626, 2023.
Artículo en Chino | WPRIM | ID: wpr-1004798

RESUMEN

Objective To investigate the infection of human parvovirus B19 in Suzhou voluntary blood donors under the current blood screening model. Methods A total of 893 blood donor samples from September to December 2022 were randomly collected. Samples were tested to determine the seroprevalence (anti-B19 IgG and IgM) of B19 antibodies by enzyme-linked immunosorbent assay(ELISA), and B19 DNA of positive samples was further detected by real-time polymerase chain reaction(PCR) assay. Results Among 893 samples, the total seroprevalence of B19 antibody was 20.7% (185/893), with anti-B19 IgG and IgM positive rate at 19.4% (173/893) and 1.9% (17/893), respectively, showing significant difference (P0.05). The prevalence of anti-B19 IgG statistically increased with age (P0.05). No statistical difference was not found in anti-B19 IgG and IgM samples among different blood groups. The anti-B19 IgG in repeated blood donors was higher than that in first-time donors(21.5% vs 15.9%)(P0.05). Three cases were found to be positive for B19 DNA in the B19 antibody positive samples, with the positive rate at 1.6%(3/185). Conclusion Although the prevalence of B19 infection in Suzhou was lower than that in other areas and was mostly past infection, there was still a certain proportion of persistent infection and acute infection, which posed the potential risk of blood transfusion transmission. Therefore, attention should be paid to blood transfusions, especially for the high-risk and susceptible groups.

3.
Chinese Journal of Blood Transfusion ; (12): 795-799, 2022.
Artículo en Chino | WPRIM | ID: wpr-1004166

RESUMEN

【Objective】 To study the incidence and specificity of platelet antibody in blood donors in Suzhou, analyze the distribution characteristics of platelet antibody in blood donors in this area, and explore the significance of platelet antibody detection in blood donors to reduce the adverse reactions toplatelet transfusion in clinical. 【Methods】 Platelet antibody detection was performed in 2178 blood donors in this area by solid-phase immunosorbent assay. The antibody specificity of the positive samples was analyzed by commercial kit, and the anti-CD36 antibody positive samples were further identified by flow cytometry and gene sequencing. 【Results】 Twelve positive samples were detected by platelet antibody screening, with a positive rate of 0.55%(12/2 178), including 5 males (0.33%, 5/2 178)and 7 females(1.06%, 7/2 178). Among the positive samples, anti-HLA-Ⅰ antibody was identified in 2 cases, anti-CD36 antibody in 1 case, and the antibody specificity was not identified in the other 9 cases. In one case, the positive rate of anti-HLA-Ⅰ antibody PRA was 31.31%(31/ 99), which was mainly specific to anti-B15, anti-B35 and anti-B40. The positive rate of anti-HLA-Ⅰ antibody PRA in the other case was 45.45%(45/ 99), which was mainly specific to anti-A2, anti-A11, anti-A24, anti-A29, anti-A33, anti-A66, anti-B15 and anti-B35. The blood donor with anti-CD36 antibody was type I CD36 deficiency, and 329_330delAC mutation occurred in exon 5. 【Conclusion】 Through antibody screening and specificity identification, the positive rate of platelet antibody in females was significantly higher than that in males(P<0.05). In addition to the common anti-HLA-I antibodies, anti-CD36 antibody was also detected in type I CD36 deficient blood donor. Therefore, the detection of platelet antibodies in blood donors is of certain clinical significance to reduce the adverse reactions to blood transfusion caused by antibodies in platelet products.

4.
Chinese Journal of Blood Transfusion ; (12): 585-589, 2021.
Artículo en Chino | WPRIM | ID: wpr-1004489

RESUMEN

【Objective】 To investigate the expression of CD36 antigen in Suzhou area, analyze the type of antigen deficiency and gene mutation, so as to provide references for the establishment of CD36 negative donor registry in Suzhou. 【Methods】 Anticoagulant whole blood samples (805 cases) were randomly collected from healthy blood donors in Suzhou Blood Center. The expression of CD36 antigen on platelet and monocyte was analyzed by flow cytometry to determine the type of CD36 deficiency. The gene mutation type of platelet CD36 antigen-deficient was performed by genomic DNA sequencing. 【Results】 The CD36 deficiency frequency on platelet was 2.48% (20/805), among which TypeⅠ(lacking CD36 expression both on platelet and monocyte) and TypeⅡ(lacking CD36 expression on platelet only) CD36 deficiency accounted for 10% (2/20) and 90% (18/20), respectively. CD36 gene mutations were found in 10 samples, including 3 cases of 329_330 delAC, 1 case of 1228_1239 delATTGTGCCTATT and 2 cases of 1163 A>T; 1 case of 329_330 delAC+ 1172_1183 delTATTGGTCAAGC and 287 G>C+ 329_330 delAC heterozygous mutation. In addition, 1 case of 745 A>G and 1 case of 806 C>T mutations were novel, and not yet reported. 【Conclusion】 Results showed that the frequency of CD36 antigen deficiency in Suzhou were similar to that reported in southern China, but the mutation sites were slightly different. The establishment of CD36 negative platelet registry could provide negative platelets for patients with transfusion reactions caused by anti-CD36 antibody and improve the effect of clinical platelet transfusion.

5.
Chinese Journal of Microbiology and Immunology ; (12): 607-614, 2016.
Artículo en Chino | WPRIM | ID: wpr-498455

RESUMEN

Objective To investigate the feasibility of using leukocytes that were filtered out by LeukoReduction System ( LRS) to replace conventional human peripheral blood leukocytes in experimental researches and to comparatively analyze the differences between them in vitro biological functions and pheno-types of T cells. Methods Mononuclear cells were isolated from LRS-separated leukocytes and whole blood sample that collected from the same person by using Ficoll. Fluorescence-activated cell sorting ( FACS) was performed to analyze the phenotypes of T cells. CD3+T cells were sorted out by using magnetic beads. The T cells that were collected by using two different ways were incubated with anti-CD3 and anti-CD28 antibodies and IL-2 in vitro for 10 days. Several assays including cell counting, FACS and cytometric beads array ( CBA) were performed to comparatively analyze the differences in biological functions and phenotypes of T cells that were isolated by different methods. Results The phenotypes of T cells isolated from LRS filter and whole blood sample were highly similar at the initial stage. The sorting rate of CD3+T cells form LRS filter reached a high level and met the requirements for experimental researches. No statistically significant differ-ences in cell count, phenotype, expression of costimulatory molecules and cytokine secretion were observed between T cells isolated from LRS filter and whole blood sample. Conclusion This study suggested that the T cells isolated from LRS filter could be used as an alternative to whole blood T cells for fundamental resear-ches since they were similar in cell vitality, phenotype and biological functions. It provided a new way to solve the problem of blood shortage in clinic and scientific research.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA