Journal of Gorgan University of Medical Sciences. 2014; 16 (1): 82-88
en Persa | IMEMR | ID: emr-157579

RESUMEN

Different coagulants including aluminum sulfate [Alum] and Polyaluminum Chloride [PAC] are used for water clarification process and deposition of colloidal particles. The use of coagulants causes some residual aluminum in water. The residual aluminum higher than 0.2 mg/l, has adverse effects on human health and environment. This study was conducted to determine the amount of residual aluminum by applying Polyaluminium chloride and aluminum sulfate for turbidity removal from turbid water. In this laboratory study, the experiments were run by using synthetic water having low [10-30 NTU], medium [100-130 NTU] and high [200-230 NTU] initial turbidities. Synthetic turbid water was prepared by adding stock kaolin suspension into distilled water. Samples of 1 liter of water were poured on 6 Jars. After adjusting of pH, coagulant was added into each beaker at various doses and agitated at 100 rpm for 30s. The mixing speed was then reduced to 20 rpm and kept for another 15 minutes. The suspensions were left for sedimentation and after 30 minutes of sedimentation, clarified samples were collected from the top of the beakers. Residual turbidity and residual aluminum was measured. The residual turbidity was measured using a Turbidimeter according to Nephlometric method. The residual aluminum was determined by Eriochrome cyanine R method. Residual alminium in low, medium and high turbidities was 0.006 mg/l, 0.05 mg/l and 0.07 mg/l by applying Polyaluminum Chloride and 0.065 mg/l, 0.15 mg/l and 0.22 mg/l by applying alum, respectively. There was a significant correlation between dosage of Alum and Polyaluminum Chloride with residual aluminium [P<0.05]. Polyaluminum Chloride due to low sensitivity to pH variation and less residual aluminum in treated water is more suitable than alum coagulant and could be used as a recommended water coagulant


Asunto(s)
Contaminantes Químicos del Agua/análisis , Purificación del Agua , Compuestos de Aluminio/química , Sensibilidad y Especificidad , Suspensiones , Precipitación Química
2.
Iranian Journal of Environmental Health Science and Engineering. 2009; 6 (4): 247-252
en Inglés | IMEMR | ID: emr-93647

RESUMEN

During the last decade, there has been a concern about the relation between aluminum residuals in treated water and Alzheimer disease, and more interest has been considered on the development of natural coagulants such as chitosan. Chitosan, a natural linear biopolyaminosaccharide, is obtained by alkaline deacetylation of chitin. The present study was aimed to investigate the effects of alum as coagulant in conjunction with chitosan as coagulant aid on the removal of turbidity, hardness and Escherichia coli from water. A conventional jar test apparatus was employed for the tests. The optimum pH was observed between 7 to 7.5 for all turbidities. The optimum doses of alum and chitosan when used in conjunction, were 10mg/L and 1mg/L, 5mg/L and 0.5mg/L, and 5mg/L and 0.5mg/L in low, medium and high turbidities, respectively. Turbidity removal efficiency was resulted between%74.3 to%98.2 by alum in conjunction with chitosan. Residual Al[+3] in treated water was less than 0.2 mg/L, meeting the international guidelines. The results showed that turbidity decrease provided also a primary Escherichia coli reduction of 2-4 log units within the first 1 to 2 hr of treatment. Hardness removal efficiency decreased when the total hardness increased from 102 to 476mg/L as CaCO3. At low initial turbidity, chitosan showed marginally better performance on hardness, especially at the ranges of 100 to 210 mg/L as CaCO3. In conclusion, coagulant aid showed a useful method for coagulation process. By using natural coagulants, considerable savings in chemicals and sludge handling cost may be achieved


Asunto(s)
Purificación del Agua/métodos , Compuestos de Alumbre , Coagulantes , Escherichia coli , Eficiencia , Dureza