Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Inglés | IMSEAR | ID: sea-114039

RESUMEN

The depletion of water resources, both surface and subsurface and deterioration of water quality made researchers and policy makers to think of the possible remedies to make water sources potable / wholesome. There is a need to address the problems of hardness and fluoride in subsurface water on priority basis. In this direction, bench scale studies were conducted to evaluate the performance of water softeners. Indepth studies were carried out at University B.D.T College of Engineering, Davangere, Karnataka, to assess the performance of bench scale softeners of D to H ratio 1:2, 1:3, 1:4 in removing hardness of varied concentrations from both synthetic and natural water samples. Studies revealed that irrespective of D to H ratio of softeners, the waters having hardness concentration up to 1000 mg/l can be treated to the same degree (81.68% and above). The findings of regeneration studies and cost economics are also summarized in this paper.


Asunto(s)
Conservación de los Recursos Naturales/economía , India , Resinas de Intercambio Iónico/química , Agua/análisis , Ablandamiento del Agua/economía , Abastecimiento de Agua/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA