1.
The Journal of Korean Knee Society ; : 187-189, 2014.
Artículo en Inglés | WPRIM | ID: wpr-759137

RESUMEN

This report presents the case of a 30-year-old motocross (BMX) cyclist with a third-degree posterior cruciate ligament rupture. The technique used for reconstruction was the transtibial single-bundle autologous hamstring technique. Unfortunately, the procedure was complicated by a popliteal pseudoaneurysm, which was located in line with the tibial canal. The pseudoaneurysm was treated with an end-to-end anastomosis and the patient recovered without further complaints. In this case, the popliteal artery was damaged most probably by the edge of the reamer or the guide wire during removal. Vascular complications can be limb- and life-threatening. This case report aims to increase the awareness of this serious complication with a review of the literature.


Asunto(s)
Adulto , Humanos , Aneurisma Falso , Arteria Poplítea , Ligamento Cruzado Posterior , Rotura