Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Braz. dent. sci ; 20(2): 62-69, 2017. Ilus, graf, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-837460

RESUMEN

Objectives: Among all desired requirements to dental prosthesis, marginal adaptation and passive fit are the most important. In some cases, in order to achieve these goals, it is necessary to cut and weld the teeth / implant-supported framework. Nowadays, the laser welding process shows a great advantage in comparison to other methods. The aim of this study was to evaluate the optimal laser welds point that is more appropriate to Ni-Cr prosthetic framework. Material and methods: A total of 60 specimens of Ni-Cr (35 mm x 4 mm) were designed and welded using a Nd:YAG laser device model EV 900. They were fixed in a metal piece 0.27 mm between the ends to be welded. All specimens were welded with 21 laser pulses diametrically opposed (frequency of 1.0Hz, load time 3.0 ms and 0.5 mm of diameter pulse). They were divided into three groups according to the electric current of the laser weld: A ­ 180A; B ­ 200A; C ­ 220A; and D- control group with no welding process. To determinate the flexural mechanic strength, all specimens were submitted to a three-point bending test. Results: The results obtained were: Group A = 553,76 Mpa; B = 751,02 Mpa and C = 802.13 Mpa. The control group was 1040.9 Mpa. ANOVA and Tukey's test were performed and statistical significance differences were observed between group A and B as well as between group A and C. However, no significant difference was observed between B and C. The group D (no welding process), significant difference was observed between A, B and C. Conclusion: According to the methodology used, the groups B and C, among the welded groups, produced higher values of mechanical strength than the group A. The groups B and C were similar.(AU)


Objetivos: Entre os requisitos de uma prótese fixa estão a adaptação marginal e seu assentamento passivo. Em alguns casos, para alcançarmos estes requisitos, devemos realizar o seccionamento e soldagem da infraestrutura metálica. Os procedimentos de soldagem a laser apresentam várias vantagens em relação aos outros processos de união. O objetivo deste trabalho foi avaliar os parâmetros ideais para soldagens a laser em de infraestruturas protéticas em Ni-Cr. Material e métodos: Foram confeccionados 60 infraestruturas (35 mm X 4,0 mm), que foram soldadas utilizando um aparelho de solda a laser Nd:YAG modelo EV 900. As amostras foram fixadas em uma peça metálica, mantendo padronizada uma distância de 0,27 mm entre as extremidades a serem unidas. Todas as amostras foram soldadas com 21 pulsos diametralmente opostos (frequência de 1,0 Hz, tempo de carga de 3,0 ms e 0,5 mm de diâmetro do pulso) e foram divididas em três grupos experimentais, alterando-se a intensidade da corrente elétrica da solda a laser: A) 180 A; B) 200 A; C) 220 A e D) grupo controle -sem processo de soldagem. Para se determinar a resistência mecânica flexural, todas as amostras foram submetidas ao teste de flexão de três pontos em máquina de teste universal. Resultados: Os resultados médios obtidos foram: grupo A) 553 Mpa, B) 751,0 Mpa, C) 802,1 Mpa e para a amostra controle foi de 1040,9 Mpa. Foram realizados o teste estatístico paramétrico ANOVA e o teste de Tukey, e foi observado diferença estatisticamente significante entre os grupos A x B e grupos A x C. No entanto, não foi observado diferença significante entre os grupos B x C. No Grupo D (sem processo de soldagem) foi observado diferença significante quando comparado com os grupos A, B e C. Conclusão: De acordo com a metodologia utilizada o grupo C produziu os maiores valores de resistência flexural, seguidos pelos grupos B e A respetivamente.(AU)


Asunto(s)
Prótesis Dental , Soldadura Dental
2.
Rev. Assoc. Paul. Cir. Dent ; 69(2): 128-134, 2015. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-770813

RESUMEN

O correto restabelecimento da dimensão vertical de oclusão (DVO), do posicionamento mandibular e do nivelamento do plano oclusal devem ser requisitos básicos nas reabilitações onde houve um colapso oclusal. Porém, em muitos casos essas soluções requerem tratamentos complexos e de alto custo para a maioria da população. O presente trabalho teve como objetivo revisar os princípios envolvidos, indicação clínica, planejamento e execução, com o objetivo de discutir a viabilidade clínica e efetividade de próteses parciais removíveis (PPR) provisórias tipo Overlay e do nivelamento oclusal com o auxílio do dispositivo de Broadrick, identificando suas indicações, vantagens e desvantagens através da apresentação de um caso clínico. Concluiu-se que a PPR tipo Overlay pode ser indicada como alternativa de tratamento para pacientes com necessidade do nivelamento oclusal e do restabelecimento da DVO, podendo ser empregada como tratamento temporário ou definitivo; e o método de Broadrick pode ser útil na orientação da determinação da curva de Spee em pacientes com plano oclusal desequilibrado.


The correct restoration of vertical dimension of occlusion, the mandible positioning and leveling of the occlusal plane should be basic requirements in rehabilitation where there was a collapse occlusal. But in many cases these solutions require complex treatments and expensive for the vast majority of the population. This study aimed to review the principals involved, clinical indication, planning, in order to discuss the feasibility and clinical effectiveness of prosthesis type overlay and leveling the occlusal technique Broadrick, identifying their indications, advantages and disadvantages through the presentation of a clinical case. It was concluded that the overlay PPR may be an alternative treatment for patients in need of restoring the vertical dimension may be used as temporary or permanent treatment, and the method Broadlick may be useful in determining the orientation of the curve of Spee in patients with occlusal plane incorrect.


Asunto(s)
Oclusión Dental , Diseño de Prótesis Dental/métodos , Prótesis Dental/métodos , Prótesis Dental , Restauración Dental Provisional/métodos , Restauración Dental Provisional
3.
Dent. press implantol ; 7(4): 52-59, Oct.-Dec. 2013. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-727367

RESUMEN

A reabilitação bucal com implantes tem se tornado uma ótima opção de tratamento; no entanto, implantes mal posicionados muitas vezes apresentam dificuldade em uma resolução estética favorável. O presente trabalho teve como objetivo relatar uma abordagem alternativa para uma condição clínica de posicionamento desfavorável de implantes, com um planejamento protético inicial também desfavorável. Por meio de uma caso clínico foi apresentada uma alternativa viável para essas situações, de coroas individuais sobre implante com gengiva artificial, trazendo de volta a região das papilas, demonstrando ser essa uma alternativa eficiente no que diz respeito à estética e de fácil higienização — fator importante na manutenção da saúde peri-implantar


Oral rehabilitation with implants has become a great treatment option, however, poorly positioned implants often present dificulty in a esthetically favorable resolution. This study aimed to describe an alternative approach to clinical conditions with unfavorable positioning of implants and also unfavorable initial prosthetic planning. By means of a clinical case report it was presented a viable alternative for these situations, using individual crowns over implant with artificial gingiva, giving back the poper papillae region, proving to be an effective alternative with aesthetic benefits and easy cleaning, an important factor in maintaining peri-implant health


Asunto(s)
Humanos , Femenino , Implantes Dentales de Diente Único , Fracaso de la Restauración Dental , Prótesis Periodontal , Procedimientos Quirúrgicos Preprotésicos Orales/efectos adversos , Brasil , Diseño de Prótesis Dental , Estética Dental , Encía
4.
Rev. Assoc. Paul. Cir. Dent ; 62(3): 232-240, maio-jun. 2008. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-539254

RESUMEN

Objetivo: Avaliar, in vitro, a precisão dos modelos obtidos a partir de transferentes cônicos dos sistemas Nobel Biocare (TB), Conexão (TC), Neodent (TN) e Dentoflex (TD) sobre implantes de hexágono externo (HE) das respectivas marcas (comparação intra-sistemas) e em combinações entre eles (comparação intersistemas). MATERIAIS E MÉTODOS: Sobre uma matriz de aço inox na qual foi instalado um implante de cada sistema citado anteriormente, foram realizadas moldagens utilizando silicone de adição, distribuídas da seguinte forma: Grupo A: TB sobre implante Nobel Biocare (IB), TC sobre implante Conexão (IC), TN sobre implante Neodi:mt (IN) e TD sobre implante Dentoflex (ID); Grupo B: TC sobre IB, TN sobre IC, TD sobre IN e TB sobre ID; Grupo C: TN sobre IB, TD sobre IC, TB sobre IN e TC sobre ID e no Grupo D: TD sobre IB, TB sobre IC, TC sobre IN e TN sobre ID. Os modelos obtidos foram analisados em um projetor de perfil e foram avaliadas as alterações na distância horizontal e na rotação de cada análogo em relação aos implantes instalados no modelo matriz. RESULTADOS: Os resultados intersistemas variaram na distância horizontal entre 0,74% (TB/IB) a 2,28% (TD/ID) e na rotação entre 01°04' (TB/IB) a 09°54' (TD/ID), enquanto que, na comparação intra-sistemas, as alterações na distância horizontal foram de 0,55% (TB/IC) a 2,49% (TC/ID) e na rotação de 01°33' (TB/IN) a 05°54' (TC/ID). CONCLUSÃO: Todos os modelos obtidos nas combinações apresentaram diferenças significativas (p = 0.0048) com os implantes instalados no modelo matriz utilizando o teste ANOVA.


Objective: evaluate the precision of the impression carried through with conical transfers of system Nobel Biocare (TB), Conexão (TC), Neodent (TN) and Dentoflex (TD) on implantations of external hexagon of the respective system and in combinations between them. A matrix model was constructed and on same, installed an implantation of each cited system previously. Metallic tray also was confectioned and the material of choice for all the impressions was the silicone of polymerization for addition. The impressions had been divided in four distributed groups of the following form: Group A: TB on Nobel Biocare implant (IB), TC on Conexão implant (IC), TN on Neodent implant (IN) and TD on Dentoflex implant (ID); Group B: TC on IB, TN on IC, TD on IN and TB on ID; Group C: TN on IB, TD on IC, TB on IN and TC on ID and in Group D: TD on IB, TB on IC, TC on IN and TN on ID. The models had been analyzed in a Projector of Profile where they had been verified in the horizontal distance and the rotation of each analogue in relation to implants installed in the matrix model. Results: inter-systems in horizontal distance ranged between 0,74% (TB/IB) to 2.28% (TD/ID) and the rotation between 01°04' (TB/IB) to 09°54' (TD/ID) while in comparison intra-system changes in horizontal distance was 0.55% (TB/IC) to 2,49% (TC/ID) and the rotation of 01°33 (TB/IN) to 05°54'(TC/ID). Conclusion: All models obtained in combinations showed significant differences (p = 0.0048) using ANOVA test.


Asunto(s)
Implantación Dental Endoósea , Técnica de Impresión Dental , Modelos Dentales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA