Clinical Endoscopy ; : 363-370, 2021.
Artículo en Inglés | WPRIM | ID: wpr-897789

RESUMEN

Background/Aims@#Probe-based confocal laser endomicroscopy (pCLE) requires the administration of intravenous (IV) fluorescein. This study aimed to determine the optimal dose of IV fluorescein for both upper and lower gastrointestinal (GI) tract pCLE. @*Methods@#Patients 20 to 79 years old with gastric high-grade dysplasia (HGD) or colorectal neoplasms (CRNs) were enrolled in the study. The dose de-escalation method was employed with five levels. The primary endpoint of the study was the determination of the optimal dose of IV fluorescein for pCLE of the GI tract. The reduced dose was determined based on off-line reviews by three endoscopists. An insufficient dose of fluorescein was defined as the dose of fluorescein with which the pCLE images were not deemed to be visible. If all three endoscopists determined that the tissue structure was visible, the doses were de-escalated. @*Results@#A total of 12 patients with gastric HGD and 12 patients with CRNs were enrolled in the study. Doses were de-escalated to 0.5 mg/kg of fluorescein for both non-neoplastic duodenal and colorectal mucosa. All gastric HGD or CRNs were visible with pCLE with IV fluorescein at 0.5 mg/kg. @*Conclusions@#In the present study, pCLE with IV fluorescein 0.5 mg/kg was adequate to visualize the magnified structure of both the upper and lower GI tract.

2.
Clinical Endoscopy ; : 363-370, 2021.
Artículo en Inglés | WPRIM | ID: wpr-890085

RESUMEN

Background/Aims@#Probe-based confocal laser endomicroscopy (pCLE) requires the administration of intravenous (IV) fluorescein. This study aimed to determine the optimal dose of IV fluorescein for both upper and lower gastrointestinal (GI) tract pCLE. @*Methods@#Patients 20 to 79 years old with gastric high-grade dysplasia (HGD) or colorectal neoplasms (CRNs) were enrolled in the study. The dose de-escalation method was employed with five levels. The primary endpoint of the study was the determination of the optimal dose of IV fluorescein for pCLE of the GI tract. The reduced dose was determined based on off-line reviews by three endoscopists. An insufficient dose of fluorescein was defined as the dose of fluorescein with which the pCLE images were not deemed to be visible. If all three endoscopists determined that the tissue structure was visible, the doses were de-escalated. @*Results@#A total of 12 patients with gastric HGD and 12 patients with CRNs were enrolled in the study. Doses were de-escalated to 0.5 mg/kg of fluorescein for both non-neoplastic duodenal and colorectal mucosa. All gastric HGD or CRNs were visible with pCLE with IV fluorescein at 0.5 mg/kg. @*Conclusions@#In the present study, pCLE with IV fluorescein 0.5 mg/kg was adequate to visualize the magnified structure of both the upper and lower GI tract.

3.
Gut and Liver ; : 673-684, 2020.
Artículo en Inglés | WPRIM | ID: wpr-833175

RESUMEN

This systematic review aimed to assess the efficacy of the current approach to tissue traction during the endoscopic submucosal dissection (ESD) of superficial esophageal cancer, early gastric cancer, and colorectal neoplasms.We performed a systematic electronic literature search of articles published in PubMed and selected comparative studies to investigate the treatment outcomes of tractionassisted versus conventional ESD. Using the keywords, we retrieved 381 articles, including five eligible articles on the esophagus, 13 on the stomach, and 12 on the colorectum. A total of seven randomized controlled tri-als and 23 retrospective studies were identified. Clip line traction and submucosal tunneling were effective in re-ducing the procedural time during esophageal ESD. The efficacy of traction methods in gastric ESD varied in terms of the devices and strategies used depending on the le-sion location and degree of submucosal fibrosis. Several prospective and retrospective studies utilized traction de-vices without the need to reinsert the colonoscope. When pocket creation is included, the traction devices and methods effectively shorten the procedural time during colorectal ESD. Although the efficacy is dependent on the organ and tumor locations, several traction techniques have been demonstrated to be efficacious in facilitating ESD by maintaining satisfactory traction during dissection.

4.
Gut and Liver ; : 263-269, 2013.
Artículo en Inglés | WPRIM | ID: wpr-158242

RESUMEN

Due to the widespread acceptance of gastric and esophageal endoscopic submucosal dissections (ESDs), the number of medical facilities that perform colorectal ESDs has grown and the effectiveness of colorectal ESD has been increasingly reported in recent years. The clinical indications for colorectal ESD at the National Cancer Center Hospital, Tokyo, Japan include laterally spreading tumor (LST) nongranular type lesions >20 mm and LST granular type lesions >30 mm. In addition, 0-IIc lesions >20 mm, intramucosal tumors with nonlifting signs and large sessile lesions, all of which are difficult to resect en bloc by conventional endoscopic mucosal resection (EMR), represent potential candidates for colorectal ESD. Rectal carcinoid tumors less than 1 cm in diameter can be treated simply, safely, and effectively by endoscopic submucosal resection using a ligation device and are therefore not indications for ESD. The en bloc resection rate was 90%, and the curative resection rate was 87% for 806 ESDs. The median procedure time was 60 minutes, and the mean size for resected specimens was 40 mm (range, 15 to 150 mm). Perforations occurred in 23 (2.8%) cases, and postoperative bleeding occurred in 15 (1.9%) cases, but only two perforation cases required emergency surgery (0.25%). ESD was an effective procedure for treating colorectal tumors that are difficult to resect en bloc by conventional EMR. ESD resulted in a higher en bloc resection rate as well as decreased invasiveness in comparison to surgery. Based on the excellent clinical results of colorectal ESDs in Japan, the Japanese healthcare insurance system has approved colorectal ESD for coverage.