1.
Artículo en Chino | WPRIM | ID: wpr-1019094

RESUMEN

Objective To investigate the effects of high concentration of semen samples in detection by fully automated sperm quality analyzer for sperm concentration,progressive motility(PR),non-progressive motility(NP)and percentage of immotile sperm(IM).Methods The semen samples from the patients who visited the reproductive clinic in our hospital from February 2023 to May 2023 were analyzed using the fully automated sperm quality analyzer.A total of 155 semen samples with initial sperm concentration ≥100× 106/mL and semen volume ≥1.5 mL were set as the high concentration semen group(group A).The semen samples with self seminal plasma dilution group(group B)and 37 ℃ normal saline dilution group(group C)were prepared with their own seminal plasma and normal saline at 1∶2 dilution ratio respectively.The sperm concentration of group A was detected by the manual method as the control.The sperm concentration and motility parameters of each group were detected.The differences of sperm concentration and the values of PR,NP and IM among the group A,B and C were analyzed.The correlations between sperm concentration and PR,NP and IM were also assessed.Results The sperm concentration of group A was significantly lower than that of the control group and groups B and C(all P<0.05).There was no statistically significant difference for the results between group B and group C(P>0.05).The PR in group C was significantly lower than that in groups A and B(all P<0.05),and there was no significant difference of PR between group A and group B(P>0.05).The values of NP in group A was significantly higher than that in groups B and C(all P<0.05),and there was no significant difference in NP between group B and group C(P>0.05).The IM in group A was significantly lower than that in groups B and C(all P<0.05),and there was no statistical difference of IM values between group B ang group C(P>0.05).Conclusion The direct analysis of undiluted semen samples with high sperm concentration may lead to lower results of sperm concentration,increased percentage of NP sperm and decreased percentage of IM sperm.The dilution of semen samples may improve the accuracy of the detec-tion results.The dilution with 37 ℃ normal saline can lead to decrease of the percentage of PR sperm.The self seminal plasma should be recommended as the first choice of diluent for the semen samples with high sperm concentration.

2.
Artículo en Chino | WPRIM | ID: wpr-991016

RESUMEN

Objective:To explore the construction of a Logistic prediction model and countermeasures for type 2 diabetic nephropathy based on clinical data.Methods:The patients with type 2 diabetic nephropathy admitted to Shijiazhuang Second Hospital from September 2019 to September 2021 (study group) were selected and the patients were selected according to a 1∶1 ratio using individual matching (control group), each group with 200 patients. Single and multiple factors analysis were used to analyze the factors influencing type 2 diabetic nephropathy, and Logistic regression equation models were developed to verify their predictive value.Results:Logistic regression equation model showed that the course of type 2 diabetes, glycosylated hemoglobin (HbA 1c), fasting plasma glucose (FPG), homocysteine (Hcy), urinary microalbumin, and serum creatinine (Scr) were high risk factors for type 2 diabetic nephropathy ( P<0.05). The results of Logistic regression model evaluation showed that the model was established with statistical significance, and the coefficients of the regression equations had statistically significant differences. The Hosmer-Lemeshow goodness-of-fit test showed that the model fitting effect was good. Logistic regression model was used to statistically analyzed the data set, and the receiver operating characteristic (ROC) curve of type 2 diabetic nephropathy was drawn, the area under the curve was 0.949(95% CI 0.922 - 0.968), the prediction sensitivity was 81.50%, the specificity was 95.50%, the calibration curve showed that the predicted results was in good agreement with the observed results. Conclusions:The independent predictors of type 2 diabetic nephropathy involve HbA 1c, FPG, Hcy, urinary microalbumin. The Logistic prediction model based on these predictors has reliable predictive value and can help guide clinical diagnosis and treatment.

3.
Artículo en Chino | WPRIM | ID: wpr-613488

RESUMEN

Objective To build anautoverification system for hematology analysis system and validate the system based on commercialized labXpert software.Methods Preliminary validation rules was established base on 41 Items of International Consensus Review Rules and instructions for Mindray CAL8000 auto hematology analyzer,and input the rules into labX pert sample validation system.999 clinical samples were collected from Beijing Hospital Ministry of Health to test the preliminary rules and parameters including false positive rate,false negative rate and autoverification pass rate were calculated,based on which to adjust and customize the original protocol.Then 15 934 samples were tested,respectively,for autoverification by calculating the autoverification pass rate,proportion of manual verification and microscopic verification.Autoverification were compared as well as the turnover time (TAT,timefrom receipt of sample to report of result) before and after application of autoverification system.Results Preliminary verification results showed that false negative rates in both hospitals were less than 2%,and the false negative mainly caused by low promyelocytic cells value (blasts and promyelocytes less than 3 %),abnormal erythrocyte morphology,and abnormal platelet morphology.No sample with excess blasts or percentage of blasts and promyelocytes higher 3% with tested with false negative result,indicating relatively low clinical risks.Both hospitals reported with relatively high false positive rates,up to nearly 18%,using preliminary programs,which may affect the autoverification rate of the system.Based on the analyzing result of false positive results,the program was adjusted to significantly reduce the false positive rate while remaining the false negative rate low,therefore resulted with 4 remarkable increase of autoverification pass rate.Over 10,000 samples were tested with improved program,and the autoverification pass rates for hospital was 78.4 %,respectively.Primary reason causing failure of autoverification included increased IMG%,flag for immature cells and WBC exceeding set limit.Application of system reduced the TAT by 5 min (P<0.05).Conclusion Autoverificationsystem using Mindray CAL8000 auto hematology analyzer andlabXpert has been confirmed effective in reducing TAT and enhancing working efficiency while remaining low false negative rate.The autoverification pass rate tested 75%,which suggested that laboratory workers can spare more time on reexamination of abnormal samples for better blood routine report.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA