Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Journal of Korean Dental Science ; : 1-8, 2022.
Artículo en Inglés | WPRIM | ID: wpr-938000

RESUMEN

Purpose@#Intraoral scanners, desktop scanners, and cone-beam computed tomography (CBCT) are being used in a complementary way for diagnosis and treatment planning. Limited patient-based results are available about dimensional reproducibility among different three-dimensional imaging systems. This study aimed to evaluate dimensional reproducibility among patient-derived digital models created from an intraoral scanner, desktop scanner, and two CBCT systems. @*Materials and Methods@#Twenty-nine arches from sixteen patients who were candidates for implant treatments were enrolled. Different types of CBCT systems (KCT and VCT) were used before and after the surgery. Polyvinylsiloxane impressions were taken on the enrolled arches after the healing period. Gypsum casts were fabricated and scanned with an intraoral scanner (CIOS) and desktop scanner (MDS). Four test groups of digital models, each from CIOS, MDS, KCT, and VCT, respectively, were compared to the reference gypsum cast group. For comparison of linear measurements, intercanine and intermolar widths and left and right canine to molar lengths were measured on individual gypsum cast and digital models. All measurements were triplicated, and the averages were used for statistics.Bland–Altman plots were drawn to assess the degree of agreement between each test group with the reference gypsum cast group. A linear mixed model was used to analyze the fixed effect of the test groups compared to the reference group (α=0.05).Result: The Bland–Altman plots showed that the bias of each test group was –0.07 mm for CIOS, –0.07 mm for MDS, –0.21 mm for VCT, and –0.25 mm for KCT. The linear mixed model did not show significant differences between the test and reference groups (P>0.05). @*Conclusion@#The linear distances measured on the digital models created from CIOS, MDS, and two CBCT systems showed slightly larger than the references but clinically acceptable reproducibility for diagnosis and treatment planning.reproducibility for diagnosis and treatment planning.plots showed that the bias of each test group was –0.07 mm for CIOS, –0.07 mm for MDS,

2.
The Journal of Korean Academy of Prosthodontics ; : 239-243, 2020.
Artículo | WPRIM | ID: wpr-837254

RESUMEN

When the marginal fit of fixed dental prosthesis decreases, biological and technical complications, such as plaque accumulation, periodontal disease, hypersensitivity, components fracture, cement loss, can happen. The complications affect the long-term success and survival of prostheses. This case report describes a clinical procedure to minimize the marginal gap of implant-supported screw-and-cement retained prosthesis by removing prosthesis-abutment complex and burnishing the interface area. The marginal gap was measured before and after the burnishing using a stereomicroscope and compared. This technique improves the marginal fit, thereby contributing the longevity of the prosthesis.

3.
Chonnam Medical Journal ; : 36-43, 2020.
Artículo en Inglés | WPRIM | ID: wpr-787276

RESUMEN

We evaluated whether thrombus aspiration (TA) during primary percutaneous coronary intervention (PCI) reduces adverse clinical outcomes within 30-days and 1-year periods. There is no well-designed, Korean data about the clinical impact of intracoronary TA during primary PCI in patients with ST-segment elevation myocardial infarction (STEMI). From the Korea Acute Myocardial Infarction Registry-National Institute of Health, 3749 patients with STEMI undergoing primary PCI within 12 hours (60.8±12.9 years, 18.7% women) with pre-procedural Thrombolysis in Myocardial Infarction (TIMI) flow 0, 1 in coronary angiography were enrolled between November 2011 and December 2015. The patients were divided into two groups: PCI with TA (n=1630) and PCI alone (n=2119). The primary end-point was major adverse cardiac event (MACE), defined as the composite of cardiovascular death (CVD), recurrent MI and stroke for 30-days and 1-year. TA did not diminish the risk of MACE, all-cause mortality and CVD in all patients during 30-days or 1-year. After performing the propensity score matching, TA also did not reduce the risk of MACE (Hazard ratio (HR) with 95% Confidence Interval (CI):1.187 [0.863-1.633], p value=0.291), all-cause mortality (HR with 95% CI: 1.130 [0.776-1.647], p value=0.523) and CVD (HR with 95% CI: 1.222 [0.778-1.920], p value=0.384) during the 1-year period. In subgroup analysis, there was no benefit of clinical outcomes favoring PCI with TA. In conclusion, primary PCI with TA did not reduce MACE, all-cause mortality or CVD among the Korean patients with STEMI and pre-procedural TIMI flow 0, 1 during the 30-day and 1-year follow ups.


Asunto(s)
Humanos , Angiografía Coronaria , Estudios de Seguimiento , Corea (Geográfico) , Mortalidad , Infarto del Miocardio , Intervención Coronaria Percutánea , Puntaje de Propensión , Accidente Cerebrovascular , Trombectomía , Trombosis
4.
The Journal of Advanced Prosthodontics ; : 280-285, 2019.
Artículo en Inglés | WPRIM | ID: wpr-761419

RESUMEN

PURPOSE: The present study was designed to examine the clinical fit of fixed dental prosthesis fabricated by the milling-sintering method using a presintered cobalt-chromium alloy. MATERIALS AND METHODS: Two single metal-ceramic crowns were fabricated via milling-sintering method and casting method in each of the twelve consecutive patients who required an implant-supported fixed prosthesis. In the milling-sintering method, the prosthetic coping was designed in computer software, and the design was converted to a non-precious alloy coping using milling and post-sintering process. In the casting method, the conventional manual fabrication process was applied. The absolute marginal discrepancy of the prostheses was evaluated intraorally using the triple-scan technique. Statistical analysis was conducted using Mann-Whitney U test (α=.05). RESULTS: Eight patients (66.7%) showed a lower marginal discrepancy of the prostheses made using the milling-sintering method than that of the prosthesis made by the casting method. Statistically, the misfit of the prosthesis fabricated using the milling-sintering method was not significantly different from that fabricated using the casting method (P=.782). There was no tendency between the amount of marginal discrepancy and the measurement point. CONCLUSION: The overall marginal fit of prosthesis fabricated by milling-sintering using a presintered alloy was comparable to that of the prosthesis fabricated by the conventional casting method in clinical use.


Asunto(s)
Humanos , Aleaciones , Estudio Clínico , Coronas , Prótesis Dental , Métodos , Prótesis e Implantes
5.
Korean Circulation Journal ; : 217-226, 2018.
Artículo en Inglés | WPRIM | ID: wpr-738688

RESUMEN

BACKGROUND AND OBJECTIVES: Neurologic intolerance (NI) is defined as the occurrence of neurological symptoms during carotid artery stenting (CAS). Because NI is inevitable problem, it may be helpful to anticipate its occurrence. So, we studied factors associated with NI during proximal protected CAS. METHODS: We retrospectively analyzed all consecutive patients underwent proximal protected CAS from August 2012 to January 2017. RESULTS: We included total 123 patients (109 males, 72±8 years old). The total procedure time was 43±12 minutes, and mean occlusion time was 4.8±1.2 minutes. We divided CAS patients into 2 groups according to presence of NI; neurologic tolerance (NT; n=74, 60%) and NI (n=49, 40%) groups. After the univariate analysis, symptomatic carotid artery stenosis (p = 0.003), absence of anterior communicating artery (p = 0.015) and low common carotid artery occlusion pressure (CCAOP, p < 0.001) were associated with NI. After the multivariate analysis, NI was significantly associated with symptomatic carotid artery stenosis (odds ratio [OR], 5.549; p = 0.014) and systolic CCAOP≤42 mmHg (OR, 6.461; p < 0.001). In NI group, 43 patients (88%) recovered right after the balloon deflation and 2 patients were normalized within 2 hours. However, 1 had major stroke and 3 had minor strokes in 4 patients with persistent NI ≥24 hours. CONCLUSIONS: About 40% showed NI during the CAS. Most of them (88%, 43 of 49 patients) recovered after the balloon deflation, but stroke incidence was significantly higher in NI group. Symptomatic carotid artery stenosis and systolic CCAOP ≤42 mmHg were significantly associated with the development of NI during proximal protected CAS.


Asunto(s)
Humanos , Masculino , Arterias , Arterias Carótidas , Arteria Carótida Común , Estenosis Carotídea , Dispositivos de Protección Embólica , Incidencia , Análisis Multivariante , Manifestaciones Neurológicas , Estudios Retrospectivos , Stents , Accidente Cerebrovascular
6.
Korean Circulation Journal ; : 217-226, 2018.
Artículo en Inglés | WPRIM | ID: wpr-917173

RESUMEN

BACKGROUND AND OBJECTIVES@#Neurologic intolerance (NI) is defined as the occurrence of neurological symptoms during carotid artery stenting (CAS). Because NI is inevitable problem, it may be helpful to anticipate its occurrence. So, we studied factors associated with NI during proximal protected CAS.@*METHODS@#We retrospectively analyzed all consecutive patients underwent proximal protected CAS from August 2012 to January 2017.@*RESULTS@#We included total 123 patients (109 males, 72±8 years old). The total procedure time was 43±12 minutes, and mean occlusion time was 4.8±1.2 minutes. We divided CAS patients into 2 groups according to presence of NI; neurologic tolerance (NT; n=74, 60%) and NI (n=49, 40%) groups. After the univariate analysis, symptomatic carotid artery stenosis (p = 0.003), absence of anterior communicating artery (p = 0.015) and low common carotid artery occlusion pressure (CCAOP, p < 0.001) were associated with NI. After the multivariate analysis, NI was significantly associated with symptomatic carotid artery stenosis (odds ratio [OR], 5.549; p = 0.014) and systolic CCAOP≤42 mmHg (OR, 6.461; p < 0.001). In NI group, 43 patients (88%) recovered right after the balloon deflation and 2 patients were normalized within 2 hours. However, 1 had major stroke and 3 had minor strokes in 4 patients with persistent NI ≥24 hours.@*CONCLUSIONS@#About 40% showed NI during the CAS. Most of them (88%, 43 of 49 patients) recovered after the balloon deflation, but stroke incidence was significantly higher in NI group. Symptomatic carotid artery stenosis and systolic CCAOP ≤42 mmHg were significantly associated with the development of NI during proximal protected CAS.

7.
Journal of Korean Medical Science ; : 272-277, 2017.
Artículo en Inglés | WPRIM | ID: wpr-115128

RESUMEN

Obesity and metabolic syndrome is a worldwide pandemic and associated with high cardiovascular risk. Metabolic endotoxemia (ME) is thought to be an underlying molecular mechanism. It triggers toll-like receptor 4-mediated inflammatory adipokines and causes a chronic low grade inflammatory status, which results in cardiovascular risk increase. Exercise is the best nonpharmacological treatment to improve prognosis. In this study, we examined the circulating endotoxin level in Korean obese women and investigated effects of exercise on it. Women over body mass index (BMI) 25 kg/m2 participated in a resistance training exercise, Curves. At baseline and after 12 weeks exercise, tests including blood samples were taken. In Korean obese women, the fasting endotoxin was 1.45 ± 0.11 EU/mL. Ingestion of a high calorie meal led to a peak level after 2 hours (postprandial 2 hours [PP2]) and a significant rise over the 4 hours (postprandial 4 hours [PP4]) in it (1.78 ± 0.15 and 1.75 ± 0.14 EU/mL for PP2 and PP4, P < 0.05 vs. fasting). After exercise, BMI and hip circumference were reduced significantly. The total cholesterol (TC) at fasting, PP2 and PP4 were decreased significantly. All levels of circulating endotoxin at fasting, PP2 and PP4 showed reduction. But, the peak change was only significant (baseline vs. 12 weeks for PP2; 1.78 ± 0.15 vs. 1.48 ± 0.06 EU/mL, P < 0.05). We report the circulating endotoxin level in Korean obese women for the first time. Also, we establish that energy intake leads to endotoxemia and exercise suppresses the peak endotoxemia after meal. It suggests an impact for a better prognosis in obese women who follow regular exercise.


Asunto(s)
Femenino , Humanos , Adipoquinas , Índice de Masa Corporal , Colesterol , Ingestión de Alimentos , Endotoxemia , Endotoxinas , Ingestión de Energía , Ayuno , Microbioma Gastrointestinal , Cadera , Lipopolisacáridos , Comidas , Obesidad , Pandemias , Pronóstico , Entrenamiento de Fuerza , Receptores Toll-Like
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA