Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Añadir filtros








Intervalo de año
1.
The Journal of Advanced Prosthodontics ; : 118-123, 2017.
Artículo en Inglés | WPRIM | ID: wpr-179521

RESUMEN

PURPOSE: To investigate the effect of non-thermal atmospheric pressure plasma (NTAPP) treatment on shear bond strength (SBS) between resin cement and colored zirconia made with metal chlorides. MATERIALS AND METHODS: 60 zirconia specimens were divided into 3 groups using coloring liquid. Each group was divided again into 2 sub-groups using plasma treatment; the experimental group was treated with plasma, and the control group was untreated. The sub-groups were: N (non-colored), C (0.1 wt% aqueous chromium chloride solution), M (0.1 wt% aqueous molybdenum chloride solution), NP (non-colored with plasma), CP (0.1 wt% aqueous chromium chloride solution with plasma), and MP (0.1 wt% aqueous molybdenum chloride solution with plasma). Composite resin cylinders were bonded to zirconia specimens with MDP-based resin cement, and SBS was measured using a universal testing machine. All data was analyzed statistically using a 2-way ANOVA test and a Tukey test. RESULTS: SBS significantly increased when specimens were treated with NTAPP regardless of coloring (P<.001). Colored zirconia containing molybdenum showed the highest value of SBS, regardless of NTAPP. The molybdenum group showed the highest SBS, whereas the chromium group showed the lowest. CONCLUSION: NTAPP may increase the SBS of colored zirconia and resin cement. The NTAPP effect on SBS is not influenced by the presence of zirconia coloring.


Asunto(s)
Cloruros , Cromo , Molibdeno , Gases em Plasma , Plasma , Cementos de Resina
2.
The Journal of Advanced Prosthodontics ; : 183-190, 2015.
Artículo en Inglés | WPRIM | ID: wpr-194331

RESUMEN

PURPOSE: This study evaluated the fracture load of customized zirconia abutments with titanium insert according to preparation depths, with or without 5-year artificial aging. MATERIALS AND METHODS: Thirty-six identical lithium disilicate crowns (IPS e.max press) were fabricated to replace a maxillary right central incisor and cemented to the customized zirconia abutment with titanium insert on a 4.5x10 mm titanium fixture. Abutments were fabricated with 3 preparation depths (0.5 mm, 0.7 mm, and 0.9 mm). Half of the samples were then processed using thermocycling (temperature: 5-55degrees C, dwelling time: 120s) and chewing simulation (1,200,000 cycles, 49 N load). All specimens were classified into 6 groups depending on the preparation depth and artificial aging (non-artificial aging groups: N5, N7, N9; artificial aging groups: A5, A7, A9). Static load was applied at 135 degrees to the implant axis in a universal testing machine. Statistical analyses of the results were performed using 1-way ANOVA, 2-way ANOVA, independent t-test and multiple linear regression. RESULTS: The fracture loads were 539.28 +/- 63.11 N (N5), 406.56 +/- 28.94 N (N7), 366.66 +/- 30.19 N (N9), 392.61 +/- 50.57 N (A5), 317.94 +/- 30.05 N (A7), and 292.74 +/- 37.15 N (A9). The fracture load of group N5 was significantly higher than those of group N7 and N9 (P<.017). Consequently, the fracture load of group A5 was also significantly higher than those of group A7 and A9 (P<.05). After artificial aging, the fracture load was significantly decreased in all groups with various preparation depths (P<.05). CONCLUSION: The fracture load of a single anterior implant restored with lithium disilicate crown on zirconia abutment with titanium insert differed depending on the preparation depths. After 5-year artificial aging, the fracture loads of all preparation groups decreased significantly.


Asunto(s)
Envejecimiento , Vértebra Cervical Axis , Coronas , Implantes Dentales , Incisivo , Modelos Lineales , Litio , Masticación , Titanio
3.
The Journal of Advanced Prosthodontics ; : 271-277, 2015.
Artículo en Inglés | WPRIM | ID: wpr-44188

RESUMEN

PURPOSE: This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS: Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau(R)Zirconia and ZENOSTAR(R)ZR translucent) and lithium disilicate glass ceramic (IPS e.max(R)press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS: The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max(R)press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau(R)Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). CONCLUSION: The lithium disilicate glass ceramic crown (IPS e.max(R)press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau(R)Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR(R)ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau(R)Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max(R)press) had overextended margins.


Asunto(s)
Diente Premolar , Cerámica , Diseño Asistido por Computadora , Coronas , Vidrio , Litio , Cementos de Resina , Hombro , Diente
4.
The Journal of Advanced Prosthodontics ; : 166-171, 2015.
Artículo en Inglés | WPRIM | ID: wpr-144366

RESUMEN

PURPOSE: The aim of this study was to evaluate antibacterial activity and osteoblast-like cell viability according to the ratio of titanium nitride and zirconium nitride coating on commercially pure titanium using an arc ion plating system. MATERIALS AND METHODS: Polished titanium surfaces were used as controls. Surface topography was observed by scanning electron microscopy, and surface roughness was measured using a two-dimensional contact stylus profilometer. Antibacterial activity was evaluated against Streptococcus mutans and Porphyromonas gingivalis with the colony-forming unit assay. Cell compatibility, mRNA expression, and morphology related to human osteoblast-like cells (MG-63) on the coated specimens were determined by the XTT assay and reverse transcriptase-polymerase chain reaction. RESULTS: The number of S. mutans colonies on the TiN, ZrN and (Ti(1-x)Zr(x))N coated surface decreased significantly compared to those on the non-coated titanium surface (P<0.05). CONCLUSION: The number of P. gingivalis colonies on all surfaces showed no significant differences. TiN, ZrN and (Ti(1-x)Zr(x))N coated titanium showed antibacterial activity against S. mutans related to initial biofilm formation but not P. gingivalis associated with advanced periimplantitis, and did not influence osteoblast-like cell viability.


Asunto(s)
Humanos , Biopelículas , Supervivencia Celular , Microscopía Electrónica de Rastreo , Periimplantitis , Porphyromonas gingivalis , ARN Mensajero , Células Madre , Streptococcus mutans , Estaño , Titanio , Circonio
5.
The Journal of Advanced Prosthodontics ; : 166-171, 2015.
Artículo en Inglés | WPRIM | ID: wpr-144359

RESUMEN

PURPOSE: The aim of this study was to evaluate antibacterial activity and osteoblast-like cell viability according to the ratio of titanium nitride and zirconium nitride coating on commercially pure titanium using an arc ion plating system. MATERIALS AND METHODS: Polished titanium surfaces were used as controls. Surface topography was observed by scanning electron microscopy, and surface roughness was measured using a two-dimensional contact stylus profilometer. Antibacterial activity was evaluated against Streptococcus mutans and Porphyromonas gingivalis with the colony-forming unit assay. Cell compatibility, mRNA expression, and morphology related to human osteoblast-like cells (MG-63) on the coated specimens were determined by the XTT assay and reverse transcriptase-polymerase chain reaction. RESULTS: The number of S. mutans colonies on the TiN, ZrN and (Ti(1-x)Zr(x))N coated surface decreased significantly compared to those on the non-coated titanium surface (P<0.05). CONCLUSION: The number of P. gingivalis colonies on all surfaces showed no significant differences. TiN, ZrN and (Ti(1-x)Zr(x))N coated titanium showed antibacterial activity against S. mutans related to initial biofilm formation but not P. gingivalis associated with advanced periimplantitis, and did not influence osteoblast-like cell viability.


Asunto(s)
Humanos , Biopelículas , Supervivencia Celular , Microscopía Electrónica de Rastreo , Periimplantitis , Porphyromonas gingivalis , ARN Mensajero , Células Madre , Streptococcus mutans , Estaño , Titanio , Circonio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA