Chinese Journal of Stomatology ; (12): 225-228, 2012.
Artículo en Chino | WPRIM | ID: wpr-281626

RESUMEN

<p><b>OBJECTIVE</b>To identify the site of crack initiation and propagation path of clinically failed all ceramic crowns by fractographic analysis.</p><p><b>METHODS</b>Three clinically failed anterior IPS Empress II crowns and two anterior In-Ceram alumina crowns were retrieved. Fracture surfaces were examined using both optical stereo and scanning electron microscopy. Fractographic theory and fracture mechanics principles were applied to disclose the damage characteristics and fracture mode.</p><p><b>RESULTS</b>All the crowns failed by cohesive failure within the veneer on the labial surface. Critical crack originated at the incisal contact area and propagated gingivally. Porosity was found within the veneer because of slurry preparation and the sintering of veneer powder.</p><p><b>CONCLUSIONS</b>Cohesive failure within the veneer is the main failure mode of all ceramic crown. Veneer becomes vulnerable when flaws are present. To reduce the chances of chipping, multi-point occlusal contacts are recommended, and layering and sintering technique of veneering layer should also be improved.</p>


Asunto(s)
Humanos , Cerámica , Coronas , Porcelana Dental , Fracaso de la Restauración Dental , Coronas con Frente Estético , Análisis de Falla de Equipo , Microscopía Electrónica de Rastreo , Porosidad