Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Chino | WPRIM | ID: wpr-1009084

RESUMEN

OBJECTIVE@#To compare the effectiveness of lower extremity axial distractor (LEAD) and traction table assisted closed reduction and intramedullary nail fixation in treatment of femoral subtrochanteric fracture.@*METHODS@#The clinical data of 117 patients with subtrochanteric fracture of femur treated by closed reduction and intramedullary nail fixation between May 2012 and May 2022 who met the selection criteria were retrospectively analyzed. According to the auxiliary reduction tools used during operation, the patients were divided into LEAD group (62 cases with LEAD reduction) and traction table group (55 cases with traction table reduction). There was no significant difference in baseline data, such as gender, age, injured side, cause of injury, fracture Seinsheimer classification, time from injury to operation, and preoperative visual analogue scale (VAS) score, between the two groups ( P>0.05). Total incision length, operation time, intraoperative blood loss, fluoroscopy frequency, closed reduction rate, fracture reduction quality, fracture healing time, weight-bearing activity time, and incidence of complications, as well as hip flexion and extension range of motion (ROM), Harris score, and VAS score at 1 month and 6 months after operation and last follow-up were recorded and compared between the two groups.@*RESULTS@#There were 14 cases in the LEAD group from closed reduction to limited open reduction, and 43 cases in the traction table group. The incisions in the LEAD group healed by first intention, and no complication such as nerve and vascular injury occurred during operation. In the traction table group, 3 cases had perineal crush injury, which recovered spontaneously in 1 week. The total incision length, operation time, intraoperative blood loss, fluoroscopy frequency, and closed reduction rate in the LEAD group were significantly better than those in the traction table group ( P<0.05). There was no significant difference in the quality of fracture reduction between the two groups ( P>0.05). Patients in both groups were followed up 12-44 months, with an average of 15.8 months. In the LEAD group, 1 patient had delayed fracture union at 6 months after operation, 1 patient had nonunion at 3 years after operation, and 1 patient had incision sinus pus flow at 10 months after operation. In the traction table group, there was 1 patient with fracture nonunion at 15 months after operation. X-ray films of the other patients in the two groups showed that the internal fixator was fixed firmly without loosening and the fractures healed. There was no significant difference in fracture healing time, weight bearing activity time, incidence of complications, and postoperative hip flexion and extension ROM, Harris score, and VAS score at different time points between the two groups ( P>0.05).@*CONCLUSION@#For femoral subtrochanteric fracture treated by close reduction and intramedullary nail fixation, compared with traction table, LEAD assisted fracture reduction can significantly shorten the operation time, reduce intraoperative blood loss and fluoroscopy frequency, reduce incision length, effectively improve the success rate of closed reduction, and avoid complications related to traction table reduction. It provides a new method for good reduction of femoral subtrochanteric fracture.


Asunto(s)
Humanos , Fijación Intramedular de Fracturas , Clavos Ortopédicos , Tracción , Pérdida de Sangre Quirúrgica/prevención & control , Estudios Retrospectivos , Resultado del Tratamiento , Fracturas del Fémur , Fracturas de Cadera/cirugía , Extremidad Inferior , Herida Quirúrgica , Fijación Interna de Fracturas
2.
Artículo en Chino | WPRIM | ID: wpr-514289

RESUMEN

Objective To introduce a novel femoral distractor which is applied in close reduction and internal fixation (CRIF) with antegrade intramedullary nail for femoral shaft fractures.Methods From September 2010 to March 2015,85 patients with femoral shaft fracture were treated by CRIF with antegrade intramedullary nail in which our self-designed novel distractor was used.They were 64 males and 21 females,with an average age of 36.6 years.By AO classification,we had 32 cases of type 32-A,40 cases of type 32-B,and 13 cases of type 32-C.The intervals between injury and surgery averaged 7.5 days (range,from 1 to 16 days).The fracture was located at the upper shaft in 26 cases,at the middle shaft in 57 cases,at the middle shaft and ipsilateral neck in one,and at the lower shaft and ipsilateral intertrochanteric site in one.Their operation time,intraoperative blood loss,intra-and post-operative complications,and fracture union time were recorded and analyzed.Results Successful close reduction was achieved in all the 85 patients with no iatrogenic injury to major vessels or nerves.Operation time averaged 105.5 minutes;time for X-ray exposure averaged 25.8 seconds;intraoperative blood loss averaged 209.2 mL.The 85 patients received follow-ups from 8 to 24 months (mean,16.3 months).Fracture union was achieved in 83 cases after an average duration of 7.8 weeks (range,from 4 to 12 weeks),but nonunion occurred in 2 cases.One-year follow-ups revealed recovery of normal function of the affected knee in all,with no limb shortening > 10 mm,rotational angulation > 15°,or lateral or anteroposterior angulation > 10°.No incision infection,deep vein thrombosis or pulmonary embolism happened during the entire follow-up.Conclusion Our self-designed novel distractor can facilitate CRIF with antegrade intramedullary nail for femoral shaft fractures,and avoid the complications and inconvenience associated with a traction table.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA