Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Inglés | WPRIM | ID: wpr-1041928

RESUMEN

Background@#Systolic murmur suggesting the association of aortic valve (AV) stenosis or obstructive pathology in the left ventricular outflow tract (LVOT) usually requires preoperative echocardiographic evaluation for elective surgery.Case: In a 63-year-old female patient undergoing elective thoracic surgery, the systolic murmur was auscultated on the right sternal border of the second intercostal space in the preoperative patient holding area. Point-of-care (POC) transthoracic echocardiography (TTE) demonstrated a systolic jet flow in the LVOT area. The peak systolic velocity of the continuous wave Doppler tracing, aligned to the LVOT and the AV, was approximately 1.5 m/s. The peak/mean pressure gradient was 11/6 mmHg for the AV and 9/5 mmHg for the LVOT. Anesthesia was induced under continuous TTE imaging. Intraoperative transesophageal echocardiography also confirmed the absence of any cardiac pathology. @*Conclusions@#POC echocardiography offered a thorough preoperative evaluation of an unexpectedly identified systolic murmur, avoiding a potential delay in the operation schedule for conventional preoperative echocardiographic evaluation.

2.
Artículo | WPRIM | ID: wpr-836394

RESUMEN

raumatic shoulder dislocations are one of the most common major dislocations in the general population. Injury to major vessels is rarely reported as a complication of shoulder dislocations. This case report presents the traumatic dissection of the axillary artery after a simple shoulder dislocation that was managed successfully with the placement of a self-expanding stent. With the clinical manifestations of a brachial plexus injury and progressive vascular compromise in the affected arm, a major vascular injury was detected on an angiogram, and a self-expanding stent was deployed. Through immediate diagnosis and prompt intervention, serious complications, such as hypovolemic shock and even death, were averted, ultimately achieving a favorable patient outcome.

3.
Artículo en Coreano | WPRIM | ID: wpr-83469

RESUMEN

BACKGROUND: Oligonucleotide chip technology has proven to be a very useful tool in the rapid diagnosis of infectious disease. Rifampin resistance is considered as a useful marker of multidrug-resistance in tuberculosis. Mutations in the rpoB gene coding β subunit of RNA polymerase represent the main mechanism of rifampin resistance. The purpose of this study was to develop a diagnosis kit using oligonucleotide chip for the rapid and accurate detection of rifampin-resistance in Mycobacterium tuberculosis. METHOD: Tle sequence specific probes for mutations in the rpoB gene were designed and spotted onto the glass slide, oligonucleotide chip. 38 clinical isolates of Mycobacterium were tested. A part of rpoB was amplified, labelled, and hybridized on the oligonucleotide chip with probes. Results were analyzed with a laser scanner. Direct sequencing was done to verify the results. RESULT: The low-density oligonucleotide chip designed to determine the specific mutations in the rpoB gene of M. tuberculosis accurately detected rifampin resistance associated with mutations in 28 clinical isolates. Mutations at codons 531, 526, and 513 were confirmed by direct sequencing analysis. CONCLUSION: Mutant detection using oligonucleotide chip technology is a reliable and useful diagnostic tool for the detection of multidrug-resistance in M. tuberculosis.


Asunto(s)
Codificación Clínica , Codón , Enfermedades Transmisibles , Diagnóstico , ARN Polimerasas Dirigidas por ADN , Vidrio , Mycobacterium , Mycobacterium tuberculosis , Rifampin , Tuberculosis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA