RESUMEN
Abstract Objective: The objectives of this study were to evaluate an automated device for ventilatory support based on AMBU manufactured in March 2020. Methods: The ESSI-1 INC was evaluated through pulmonary mechanics and physiology parameters through compensatory spirometer tests (TISSOTs), and an artificial lung Model5600i Dual Adult PNEU VIEW SYSTEM; it was also compared to the anesthetic ventilatory support equipment (AEONMED 7500) in porcine models, measuring ventilatory, hemodynamic and gasometric parameters. Results: This equipment (ESSI-1 INC) was successfully tested by mechanical and biological models, such as pigs in which its performance was evaluated in terms of variability of tidal volume, ventilation frequency, and I/E relationship versus the manual performance of two medical interns. All the results turned out as expected and were satisfactory. Conclusions: It is safe and effective equipment and should be tested and used in diverse clinical conditions to standardize the ventilatory safety and care of patients who require it.
Resumen Objetivo: Evaluar un dispositivo automatizado para la asistencia ventilatoria basado en un AMBU manufacturado en Marzo del 2020. Métodos: El ESSI-1 INC fue evaluado por medio de parámetros fisiológicos y mecánica pulmonar a través de pruebas de espirómetro compensatorios (TISSOT); pulmón artificial (Modelo 5600i Dual Adult PNEU VIEW SYSTEM); así como su desempeño comparado a la máquina de anestesia (AEONMED 7500) en modelos porcinos, midiendo criterios ventilatorios, hemodinámicos y gasométricos. Resultados: Este equipo (ESSI-1 INC) fue exitosamente probado por modelos mecánicos y biológicos, tales como cerdos donde su desempeño fue evaluado en términos de la variabilidad del volumen tidal, frecuencia ventilatoria, y relación I/E versus el desempeño manual de dos médicos. Todos los resultados finalizaron como se esperaba de forma satisfactoria. Conclusiones: Es un equipo seguro y efectivo, el cual debería ser probado y usado en distintas condiciones clínicas para estandarizar la seguridad ventilatoria y cuidado de pacientes que lo requieran.
RESUMEN
Abstract Introduction: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. Objective: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs antiproliferative activity and histological results. Method: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. Results: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. Conclusions: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.
Resumen Introducción: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. Objetivo: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. Método: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. Resultados: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. Conclusiones: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.
Asunto(s)
Animales , Masculino , Femenino , Conejos , Paclitaxel/administración & dosificación , Sirolimus/administración & dosificación , Stents Liberadores de Fármacos , Diseño de Prótesis , Espectrofotometría Infrarroja , Porcinos , Estudios de Seguimiento , Modelos Animales de Enfermedad , MicroscopíaRESUMEN
ABSTRACT Background: The left atrial appendage (LAAp) resection is an effective treatment approach to reduce the risk of thromboembolism in patients with atrial fibrillation. Objective: To study was to study the impact of removing atrial appendages in the production of natriuretic peptides (NPs) in conditions of volume overload and to develop an experimental model of LAAp resection. Materials and Methods: In a swine model of ischemic heart failure (HF), serum NP levels were measured before (Basal-1A) and after (Basal-1B) a fluid overload. Animals were grouped as follows: (0) preserved appendages, (1) resected LAAp, and (2) both atrial appendages resected. Levels of NP were measured before (2A) and after a fluid overload (2B). Results: Furin levels were higher in Group 0-2A than in Group 2-2A, and a significant increase was found in Group 0-2B compared to Groups 1-2B and 2-2B. Corin levels increased in Basal-1B versus Basal-1A. Atrial NP (ANP) decreased in Basal-1B compared to Basal-1A. After HF induction, ANP increased in Groups 2-2A and 2-2B. Conclusions: Resection of atrial appendages drastically modifies the natriuretic mechanisms of cardiac homeostasis, especially after a fluid overload challenge. Herein, we describe the face and predictive validation of an animal model of atrial appendage resection useful to investigations in translational medicine.
Asunto(s)
Animales , Masculino , Apéndice Atrial/cirugía , Apéndice Atrial/metabolismo , Modelos Animales de Enfermedad , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/metabolismo , Homeostasis , Porcinos , Péptidos Natriuréticos/biosíntesis , Péptidos Natriuréticos/fisiología , Centros Médicos AcadémicosRESUMEN
Debido a numerosos informes existentes en la literatura media relacionados con las complicaciones del catéter de Swan-Ganz, efectuamos este estudio prospectivo de 120 inserciones de este catéter en 119 pacientes que ameritaron monitorización hemodinámica trans y postoperatoria en cirugía cardiovascular. En todos los casos, la colocación del catéter se efectuó inmediatamente después de la inducción anestésica por punción percutánea de la vena yugular interna usando la técnica de Seldinger modificada, tomando como referencia las curvas de presión intracavitarias hasta llegar a la posición de cuña pulmonar. Se investigó el tiempo de coloración, tiempo de uso, complicaciones de la punción, dificultad y complicaciones en la inserción, complicaciones torácicas y pulmonares, asa y nudo del catéter, infección en el sitio de punción y septicemia por el catéter. Resultados: múltiples punciones en 15 casos (12.5%); punción de carótida en 8 (6.6%); hematoma 14 (11.6%); dificultad para canular ventrículo derecho 8 (6.6%) y arteria pulmonar 32 (26.6%); imposibilidad para obtener posición de cuña 13 (10.8%); formación de asa del catéter 3 (2.5%); extrasístoles auriculares 30 (25%); taquicardia auricular 4 (3.3%); extrasístoles ventriculares 73 (60.8%); incidencia de arritmia en general 67.5%, ninguna de gravedad. Todas estas complicaciones fueron menores, sin peligro para la vida del paciente. Sólo en 2 casos (1.6%) hubo una complicación mayor (infarto pulmonar ambos, que tampoco comprometieron la vida del paciente) hubo 20 casos (16.6%) que cursaron sin complicación alguna. No hubo mortalidad por el catéter. Los resultados de este estudio demuestran que las complicaciones del uso del catéter de flotación pulmonar son mínimas en relación con los beneficios obtenidos en el manejo de estos pacientes