Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. colomb. anestesiol ; 52(4): 6, Oct.-Dec. 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1576188

RESUMEN

Abstract The incorporation of new technologies such as ultrasound, J-Plasma (helium plasma) and MicroAire (power assited liposuction) has facilitated liposculpture procedures, resulting in greater patient satisfaction. The benefits of these technologies are accompanied by low reported complications; this case is the fourth description of pneumomediastinum secondary to the use of Renuvion® (J-Plasma) after liposuction for fat removal in the arms and thighs. This rare complication should be considered as part of the differential diagnosis during the study of clinical dyspnea and subcutaneous emphysema in the postoperative period.


Resumen La incorporación de nuevas tecnologías, como ultrasonido, J-Plasma (plasma de helio) y el Microaire (vibroliposucción), ha facilitado los procedimientos de lipoescultura consiguiendo una mayor satisfacción del paciente. Los beneficios de estas tecnologías se acompañan de bajas complicaciones reportadas; el presente caso constituye la cuarta descripción de neumomediastino secundario a la utilización de Renuvion® (J-Plasma) posterior a la extracción de grasa en brazos y muslos por medio de liposucción; esta infrecuente complicación se debe considerar diagnóstico diferencial en el estudio de presentación clínica de disnea y enfisema subcutáneo durante el posoperatorio.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA