Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Biosci. j. (Online) ; 39: e39037, 2023. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1428172

RESUMEN

This study evaluated the effects of ultrasonic activation (US) associated to glycolic acid (GA) on smear layer, dentin structure and bond strength (BS) of filling/restorative material to root dentin. The roots were used for antimicrobial activity, dentin structure and BS evaluation, being distributed into seven groups, according to irrigation protocols: G1:DW+US; G2:17% EDTA; G3:QMix; G4:17% GA; G5:17% EDTA+US; G6:QMix+US; G7:17% GA+US. Scanning electronic microscopy, transmission electronic microscopy and push-out were performed, with specific statistical analysis for each evaluation. The highest smear layer removal occured in Groups 6 and 7 (p<0.05), and the largest collagen dispersion in Group 7, being similar to Group 2 and 5 (p>0.05). The highest BS of filling and restorative material occurred in Groups 6 and 7, and Groups 5, 6 and 7, respectively, being similars between them (p>0.05). The use of GA+US promoted effective smear layer removal and dentin structure preservation, improving the BS of filling/restorative material to root dentin.


Asunto(s)
Ácidos , Ácido Edético , Endodoncia
2.
Dental press j. orthod. (Impr.) ; 22(4): 47-52, July-Aug. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-891086

RESUMEN

ABSTRACT Objective: The aim of this in vitro study was to evaluate and compare the effects of grinding, drilling, sandblasting, and ageing prefabricated teeth (PfT) on the shear bond strength (SBS) of orthodontic brackets, as well as the effects of surface treatments on the adhesive remnant index (ARI). Methods: One-hundred-ninety-two PfT were divided into four groups (n = 48): Group 1, no surface treatment was done; Group 2, grinding was performed with a cylindrical diamond bur; Group 3, two drillings were done with a spherical diamond bur; Group 4, sandblasting was performed with 50-µm aluminum oxide. Before the experiment, half of the samples stayed immersed in distilled water at 37oC for 90 days. Brackets were bonded with Transbond XT and shear strength tests were carried out using a universal testing machine. SBS were compared by surface treatment and by ageing with two-way ANOVA, followed by Tukey's test. ARI scores were compared between surface treatments with Kruskal-Wallis test followed by Dunn's test. Results: Surface treatments on PfT enhanced SBS of brackets (p< 0.01), result not observed with ageing (p= 0.45). Groups II, III, and IV showed higher SBS and greater ARI than the Group 1 (p< 0.05). SBS was greater in the groups 3 and 4 (drilling, sandblasting) than in the Group 2 (grinding) (p< 0.05). SBS and ARI showed a positive correlation (Spearman's R2= 0.57; p< 0.05). Conclusion: Surface treatment on PfT enhanced SBS of brackets, however ageing did not show any relevance. Sandblasting and drilling showed greater SBS than grinding. There was a positive correlation between SBS and ARI.


RESUMO Objetivo: o objetivo desse estudo in vitro foi avaliar e comparar os efeitos de desgastes, perfurações, jateamento e envelhecimento de dentes pré-fabricados (Dpf) na resistência ao cisalhamento (RC) de braquetes ortodônticos, bem como os efeitos dos tratamentos de superfície no índice de adesivo remanescente (ARI). Métodos: 192 Dpf foram divididos em quatro grupos (n = 48): Grupo 1, sem tratamento; Grupo 2, desgaste de sulcos com broca diamantada cilíndrica; Grupo 3, duas perfurações com broca diamantada esférica; e Grupo 4, jateamento com partículas de óxido de alumínio de 50µm. Antes do experimento, metade das amostras ficou imersa em água destilada a 37oC durante 90 dias. Os braquetes foram colados com Transbond XT e os testes de cisalhamento foram realizados com uma máquina universal de ensaios. A RC foi comparada, por tratamento de superfície e por envelhecimento, utilizando-se análise de variância e teste de Tukey. Os escores ARI foram comparados entre os tratamentos de superfície usando o teste Kruskal-Wallis e o teste de Dunn. Resultados: os tratamentos de superfície aumentaram a RC dos braquetes (p < 0,01) e o envelhecimento não aumentou a RC (p = 0,45). Os Grupos 2, 3 e 4 mostraram maior RC e maior ARI do que o Grupo 1 (p < 0,05). A RC foi maior nos Grupos 3 e 4 (perfuração, jateamento) do que no Grupo 2 (desgaste) (p < 0,05). RC e ARI apresentaram correlação positiva (R2 = 0,57; p < 0,05). Conclusão: o tratamento de superfície dos Dpf aumentou a RC dos braquetes; porém, o envelhecimento não foi relevante. O jateamento e a perfuração mostraram maior RC do que o desgaste. Existe uma correlação positiva entre RC e ARI.


Asunto(s)
Diente Artificial , Soportes Ortodóncicos , Propiedades de Superficie , Ensayo de Materiales , Recubrimiento Dental Adhesivo , Resistencia al Corte , Análisis del Estrés Dental
3.
Braz. oral res. (Online) ; 31: e109, 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-952095

RESUMEN

Abstract: The present study aimed to evaluate the microtensile bond strength (μTBS) of novel computer-aided design/computer-aided manufacturing (CAD/CAM) restorative materials to dentin using different adhesive strategies. Thirty-two crowns were milled using CAD/CAM materials (Vita Mark II as control, Vita Suprinity, Vita Enamic and Lava Ultimate) and luted to dentin using different resin cements (RelyX ARC, RelyX Unicem 2 and RelyX Ultimate). The specimens were stored in 100% relative humidity at 37°C for 24 h and sectioned. The samples (n = 16) with cross-sectional areas of approximately 0.90 mm2, were submitted to a μTBS test in a universal testing machine with a crosshead speed of 0.5 mm/min. The samples were analyzed with SEM to determinate the failure mode. According to 2-way ANOVA and Tukey's test (α=0.05), the interaction effect (material x luting strategy) was significant (p=0.001). Regardless of the luting strategy, a higher μTBS was obtained with Lava Ultimate and Vita Enamic, which were significantly different from Vita Mark II and Vita Suprinity (p<0.05). For Vita Mark II, Vita Suprinity, Vita Enamic, and Lava Ultimate, the μTBS obtained with RelyX Unicem 2 was not significantly different from that obtained with RelyX ARC or RelyX Ultimate. All groups obtained at least three types of failure. The adhesive strategy with self-adhesive resin cement was comparable to conventional resin cement with total-etch or self-etch adhesive techniques in the bond of novel CAD/CAM materials to dentin.


Asunto(s)
Humanos , Cerámica/química , Recubrimiento Dental Adhesivo/métodos , Diseño Asistido por Computadora , Cementos de Resina/química , Dentina/efectos de los fármacos , Propiedades de Superficie/efectos de los fármacos , Resistencia a la Tracción , Factores de Tiempo , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Reproducibilidad de los Resultados , Análisis de Varianza , Fracaso de la Restauración Dental , Dentina/química
5.
Rev. Salusvita (Online) ; 35(2): 207-217, 2016.
Artículo en Portugués | LILACS | ID: biblio-827269

RESUMEN

A história da Odontologia no Brasil iniciou-se de maneira rudimentar com instrumentos primitivos e sem preocupações com higiene. Não havia nenhuma referência à ciência, apenas à prática da profissão. No século XVII, evidencia-se um aumento no número de cáries e maior demanda por serviços odontológicos estéticos. Porém, apenas em 1879 inicia-se o estudo da Odontologia, no Brasil, e outras faculdades começam a se instalar somente a partir do século XX. A comprovação da origem bacteriana da doença cárie e surgimento de mais estudos referentes às doenças bucais ocorreram somente a partir da década de 1940. A fluoretação da água de abastecimento público foi o primeiro procedimento preventivo realizado no Brasil e o primeiro estudo epidemiológico nacional foi realizado em 1986. O Ministério da Saúde declarou que no ano de 2012, a quantidade de atendimentos odontológicos oferecidos pelo Sistema Único de Saúde foi de 150 milhões de consultas no país, além disso, o governo ampliou o sistema para 90% das cidades brasileiras atingindo uma população de 92 milhões de beneficiados e implementou serviços de promoção, prevenção e recuperação da saúde bucal. Apesar desse grande avanço, o controle da doença cárie em todas as faixas etárias ainda está longe de ser alcançado. Fazer com que todos os progressos obtidos até o momento cheguem a todos os cidadãos deve ser a meta deste século. (AU)


The history of dentistry in Brazil initiated in a rudimentary way with primitive tools and no hygiene preoccupations. There was no reference to science, only the practice of the profession. In the seventeenth century there is evidence about the increase of the number of dental caries and demand for aesthetics dental services. However, only in 1879 began the study of Dentistry in Brazil and new faculties were installed on the twentieth century. Evidence of bacterial decay and the emergence of more studies about oral diseases only occurred since the 1940s. Fluoride supplies of public water was the first preventive procedure performed in Brazil and the first national epidemiological study was conducted in 1986. The Ministry of Health stated that in the year 2012, the amount of dental care offered by the National Health System was 150 million consultations in the country, besides the government expanded the system to 90% of Brazilian cities reaching a population of 92 million of beneficiaries and implemented health promotion, prevention and recovery of oral health services. Despite this breakthrough, the control of caries in all age groups is still far from being achieved. Make all the progress made so far reaching all citizens should be the goal of this century. (AU)


Asunto(s)
Humanos , Masculino , Femenino , Odontología en Salud Pública , Educación en Odontología , Historia de la Odontología , Brasil , Caries Dental/historia
6.
Braz. oral res. (Online) ; 30(1): e77, 2016. tab, graf
Artículo en Inglés | LILACS | ID: biblio-951963

RESUMEN

Abstract The aim of this study was to evaluate the thickness of resin cements in the root thirds when using conventional fiberglass posts (CP) and relined fiberglass posts (RP) in weakened roots and to evaluate the morphological characteristics of the dentin-resin interface. Forty human maxillary anterior teeth had the crown sectioned below the cemento-enamel junction. The canals were endodontically treated and weakened with diamond burs. Teeth were divided into four groups (n = 10): Group 1 - CP + RelyX ARC; Group 2 - CP + RelyX U200; Group 3 - RP + RelyX ARC; and Group 4 - RP + RelyX U200. Prior to luting, 0.1% Fluorescein and 0.1% Rhodamine B dyes were added to an adhesive and resin cement, respectively. Slices were obtained from the apical, middle, and cervical thirds of the root. Confocal laser scanning microscopy images were recorded in four areas (buccal, lingual, mesial, distal) of each third. In each area, four equidistant measures of the resin cement were made and the mean value was calculated. The interface morphology was observed. The data were submitted to three-way ANOVA and Tukey's test (α = 0.05). The interaction between fiberglass posts, resin cement, and root thirds was significant (p < 0.0001). The resin cement thicknesses were significantly lower for RP in comparison with CP, except in the apical third. There was no significant difference between the resin cements for RP. There was formation of resin cement tags and adhesive tags along the root for RP. RP favored the formation of thin and uniform resin cement films and resin tags in weakened roots.


Asunto(s)
Humanos , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Técnica de Perno Muñón , Bisfenol A Glicidil Metacrilato/química , Cementos de Resina/química , Dentina/efectos de los fármacos , Vidrio/química , Factores de Tiempo , Raíz del Diente/efectos de los fármacos , Ensayo de Materiales , Reproducibilidad de los Resultados , Análisis de Varianza , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Microscopía Confocal , Cavidad Pulpar/efectos de los fármacos
7.
Dental press j. orthod. (Impr.) ; 17(6): 154-159, Nov.-Dec. 2012. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-669408

RESUMEN

OBJECTIVE: To evaluate the mechanical properties of three glass ionomers cements (GICs) used for band cementation in Orthodontics. METHODS: Two conventional glass ionomers (Ketac Cem Easy mix/3M-ESPE and Meron/Voco) and one resin modified glass ionomer (Multi-cure Glass ionomer/3M-Unitek) were selected. For the compressive strength and diametral tensile strength tests, 12 specimens were made of each material. For the microhardness test 15 specimens were made of each material and for the shear bond strength tests 45 bovine permanent incisors were used mounted in a self-cure acrylic resin. Then, band segments with a welded bracket were cemented on the buccal surface of the crowns. For the mechanical tests of compressive and diametral tensile strength and shear bond strength a universal testing machine was used with a crosshead speed of 1,0 mm/min and for the Vickers microhardness analysis tests a Microdurometer was used with 200 g of load during 15 seconds. The results were submitted to statistical analysis through ANOVA complemented by Tukey's test at a significance level of 5%. RESULTS: The results shown that the Multi-Cure Glass Ionomer presented higher diametral tensile strength (p < 0.01) and compressive strength greater than conventional GICs (p = 0.08). Moreover, Ketac Cem showed significant less microhardness (p < 0.01). CONCLUSION: The resin-modified glass ionomer cement showed high mechanical properties, compared to the conventional glass ionomer cements, which had few differences between them.


OBJETIVO: avaliar as propriedades mecânicas de três cimentos de ionômero de vidro (CIVs) utilizados para cimentação de anéis ortodônticos. MÉTODOS: foram utilizados dois CIVs convencionais (Ketac Cem Easy mix/3M-ESPE e Meron/Voco) e um CIV modificado por resina (Multi-Cure Glass ionomer/3M-Unitek). Para os testes de resistência à compressão e tração diametral, foram confeccionados 12 corpos de prova de cada material. Para os testes de microdureza, foram confeccionados 15 corpos de prova de cada material; para os testes de resistência de união ao cisalhamento, foram utilizados 45 dentes bovinos incluídos em resina acrílica, sobre os quais foi cimentada uma lâmina de anel ortodôntico com braquete soldado a ela para a realização dos ensaios. Para os testes de compressão, tração diametral e cisalhamento, foi utilizada uma máquina universal de ensaios a uma velocidade de 1mm/min; para os testes de microdureza Vickers, foi utilizado um microdurômetro com 200g de carga durante 15 segundos. Os resultados foram submetidos à análise estatística ANOVA, complementada pelo teste de Tukey ao nível de significância de 5%. RESULTADOS: os resultados demonstraram que o Multi-Cure Glass Ionomer apresentou resistência à tração diametral significativamente maior (p < 0,01) e maior resistência à compressão (p = 0,08) em relação aos CIVs convencionais. Além disso, o Ketac Cem apresentou microdureza significativamente maior que os demais materiais (p < 0,01). CONCLUSÃO: o CIV modificado por resina apresentou propriedades mecânicas superiores às dos CIVs convencionais, que, por sua vez, apresentaram poucas diferenças entre si.

8.
Artículo en Inglés | IMSEAR | ID: sea-142925

RESUMEN

Objective: To compare surface treatments with CVDentUS ® ultrasound tips (UT) and KGSorensen ® diamond burs (DB) on etched (e) and non-etched (n/e) dentin. The microtensile bond strength (μTBS) was measured and fractography was assessed by scanning electron microscope (SEM). Materials and Methods: Sixteen molars were divided into four groups of four teeth each according to treatment (DB-n/e; DB-e; UT-n/e; UT-e). The teeth were restored, sectioned into samples for μTBS (n=40) and tested on a EMIC DL-2000 universal machine (0.5 mm/min) and analyzed by SEM for fracture classification. Statistical Analysis: For analysis of the data on μTBS, the two-way ANOVA, using treatment and acid etching as fixed factor, and the Tukey test were used (α=0.05). To failures classification in cohesive in dentin (CD); cohesive in composite resin (CC); cohesive interfacial on base or top of hybrid layer (CBT); cohesive in adhesive (CA); mixed (M); interfacial on smear layer (S) the Fisher's exact test (α=0.05) was performed. Results: The mean values of μTBS (in MPa) in the different groups were as follows: UT-e: 45.31±8.16; DB-e: 34.04±9.29; UT-n/e: 15.17±3.71; and DB-n/e: 9.86±3.80. On analysis of the SEM micrographs, the DB-n/e group showed total obstruction of dentinal tubules; the UT-n/e group showed partial desobstruction of dentinal tubules and irregular surface; the DB-e group showed complete desobstruction of dentinal tubules; and the UT-e group showed complete desobstruction of dentinal tubules and irregular surface. Conclusion: The combination of ultrasound treatment and acid etching provides high values of μTBS. An association exists between CA/CC failures and the UT method, CBT failure and the DB method, CBT/CC failures and etching, S failure and non-etching.

9.
Rev. odonto ciênc ; 26(1): 40-44, 2011. ilus, graf
Artículo en Inglés | LILACS, BBO | ID: lil-588600

RESUMEN

PURPOSE: The present study examined the possibility of modifying the structural properties of glass ionomer cement by adding seashells to form a possible 'scaffold' material for cases of bone formation. METHODS: White and black seashells were ground into a fine, homogeneous powder. To analyze their composition, the seashell samples were submitted to EDX and X-Ray diffraction. The ground seashells were mixed with the glass ionomer cement at either 1, 5 or 10 percent concentrations (in weight). Samples without any seashells were used as the control group. Solutions and GIC samples were analyzed for pH measurement. The structural and superficial analysis of samples was performed by using scanning electron microscopy (SEM). RESULTS: There was no difference in pH values among the tested solutions with different seashell concentrations (1, 5 and 10 percent). In the GIC samples with the shells, the pH values were close to 7.0. The EDX and X-Ray diffraction showed calcium carbonate (CaCO3) peaks for the shell samples. The superficial SEM analysis demonstrated that the samples containing seashells had framework formations in their structures. CONCLUSION: Although there is a need for biocompatibility and cellular cytotoxicity testing in vitro, as well as in vivo evaluation, seashells could be used in glass ionomer cement aiming at the development of a 'scaffold' material for bone grafting or osseointegration.


OBJETIVO: Este estudo examinou a possibilidade de modificar as propriedades estruturais do cimento de ionômero de vidro (CIV) pela adição de conchas para formar um material estrutural, com objetivo de uso em casos de formação óssea. METODOLOGIA: Conchas de cor branca e preta foram transformadas em um pó fino e homogêneo e sua composição foi analisada por EDX e difração por RX. O pó de concha foi misturado a CIV nas concentrações de 1, 5 ou 10 por cento (em peso) para a confecção das amostras. Amostras sem pó de concha foram usadas como grupo controle. Foram realizadas medições de pH de soluções do pó de conchas e das amostras de CIV. A análise estrutural e superficial das amostras foi realizada por microscopia eletrônica de varredura (MEV). RESULTADOS: Não houve diferença de pH entre as soluções testadas com diferentes concentrações de pó de concha (1, 5 ou 10 por cento). Nas amostras de CIV com conchas, os valores de pH foram próximos a 7,0. Os métodos de EDX e difração por RX mostraram picos de carbonato de cálcio (CaCO3) para as amostras com conchas. A análise por MEV demonstrou que as amostras com pó de conchas tinham formações estruturais diferentes do controle. CONCLUSÃO: Embora haja necessidade de testes de biocompatibilidade e citotoxicidade celular, assim como avaliação in vivo, as conchas poderiam ser utilizadas como material de modificação estrutural do cimento de ionômero de vidro em casos de material para enxerto ósseo ou osseointegração.


Asunto(s)
Cementos de Ionómero Vítreo/química , Cementos de Ionómero Vítreo/uso terapéutico , Materiales Biocompatibles , Ensayo de Materiales
10.
Rev. odonto ciênc ; 26(2): 151-155, 2011. tab
Artículo en Inglés | LILACS, BBO | ID: lil-611662

RESUMEN

PURPOSE: The purpose of this study was to evaluate the influence of filler weight content on selected mechanical properties of six microhybrid composite resins. METHODS: Compressive strength, elastic modulus, Vickers microhardness (VHN), and weight filler content were evaluated in the following dental composites: Admira (AD), Charisma (CH), InTen-S (IN), Tetric Ceram (TC), Point 4 (P4), and Z250 (Z2). RESULTS: Mean values for compressive strength (MPa) ranged from P4 76.60 to Z2 222.33. The elastic moduli (GPa) ranged from IN 2.56 to Z2 4.59. Microhardness VHN ranged from P4 50.53 to Z2 87.88. Filler weight content (Wt percent) ranged from IN 72.51 to TC 79.56. Significant differences were found between the composites (ANOVA/Tukey's, P<0.05). CONCLUSION: Z2 had the highest compressive strength; Z2 and TC showed the highest elastic modulus, VHN and filler weight content. Weight filler content had a strong influence on mechanical properties (0.78

OBJETIVO: O objetivo deste estudo foi avaliar a influência do conteudo de carga, em peso, de seis resinas compostas microhíbrida sobre determinadas propriedades mecânicas. METODOLOGIA: A resistência à compressão, módulo de elasticidade, microdureza Vickers (VHN) e conteúdo de carga de peso foram avaliados nas seguintes resinas compostas: Admira (AD), Charisma (CH), InTen-S (IN), Tetric Ceram (TC), Point 4 (P4) e Z250 (Z2). RESULTADOS: Os valores médios de resistência à compressão (MPa) variaram de P4 76,60 a Z2 222,33. Os módulos de elasticidade (GPa) variou de IN 2,56 a Z2 4,59. A microdureza VHN variou de P4 50,53 a Z2 87,88. O conteúdo de carga em peso (Wt por cento) variou de IN 72,51 a TC 79,56. Foram encontradas diferenças significativas entre as resinas compostas (ANOVA/Tukey's, P<0,05). CONCLUSÃO: A resina Z2 teve a maior resistência à compressão; Z2 e TC apresentaram maiores módulo de elasticidade, VHN e conteúdo de carga em peso. O conteúdo de carga em peso teve uma forte influência nas propriedades mecânicas avaliadas (0,78

Asunto(s)
Fenómenos Mecánicos , Fuerza Compresiva , Resinas Compuestas
11.
Artículo en Inglés | IMSEAR | ID: sea-139807

RESUMEN

Objective: The aim of this in vitro study was to determine the effects of barium sulfate addition in two dental impression materials previously proved as radiolucent. Materials and Methods: An irreversible hydrocolloid (IH) and polyether (PE) were tested for optical density, linear dimension stability and detail reproduction. Statistical Analysis Used: The optical density data were submitted to Kolmogorov-Smirnov normality test and compared with two-way ANOVA and Tukey (alpha=0.05). Results: The results of optical density (pixel) were: IH control 45.24 f (±7.6), PE control 54.93 e (±4.45), PE 5Wt% 60.43 d (±6.27), IH 1Wt% 61.54 cd (±5.3), PE 1Wt% 66.9 bc (±5.05), IH 5Wt% 67.17 b (±6.01), PE 10Wt% 84.55 a (±5.14), IH 10Wt% 85.33 a (±5.53). On detail reproduction, polyether control was able to copy the 6 μm line. Adding 1 or 5Wt% of barium sulfate have not change this characteristic. For the irreversible hydrocolloid, the control group was able to copy a line with 14 μm, however, adding 1Wt% barium sulfate, the capability decreased to 22 μm. Adding barium sulfate in the polyether promoted an increase in between the copied lines, for the control, the average distance was 931.6 μm, 936 μm to 1Wt% and 954.5 μm to 5 Wt%. For the IH, the control presented 975 μm in comparison to 987.25 μm for 1 Wt% samples. Conclusion: The addition of barium sulfate was capable of increasing significantly the optical density of tested material, have changed the linear dimension stability, however, have not interfered in detail reproduction only for PE.


Asunto(s)
Alginatos , Análisis de Varianza , Sulfato de Bario , Medios de Contraste , Materiales de Impresión Dental/química , Ensayo de Materiales , Fenómenos Ópticos , Resinas Sintéticas , Estadísticas no Paramétricas
12.
Rev. odonto ciênc ; 24(1): 19-21, jan.-mar. 2009. tab
Artículo en Inglés | LILACS, BBO | ID: lil-506370

RESUMEN

Purpose: To evaluate the effect of chisel width on shear bond strength of composite to dental enamel. Methods: Sixty crowns of bovine incisors were embedded in acrylic resin, and their enamel surfaces were flattened and etched with 35% phosphoric acid. Single Bond (3M/ESPE) adhesive system and Z-250 (3M/ESPE) composite were used to build a cylindrical-shaped restoration perpendicular to the conditioned enamel flat surface. Specimens were divided into four groups and subjected to the shear bond strength testing using a chisel-shaped shearing blade with a 0.5, 1.0, 2.0, or 3.0 mm-width blunt edge in a universal testing machine at crosshead speed of 0.5 mm/min. Data on shear bond strength were analyzed by ANOVA and Duncan's test (á=0.05). Results: Shear bond strength means for the experimental groups were: 0.5 mm - 19.66 MPa; 1 mm - 18.78 MPa; 2 mm - 16.77 MPa; 3 mm - 16.06 MPa. Bond strength was significantly different between the groups tested with chisels of 0.5 and 3 mm-width (P=0.045) showing an inverse relationship between shear bond strength and chisel width. Conclusion: The results suggest that shear bond strength varies as a function of chisel width.


Objetivo: Avaliar a influência de diferentes larguras de cinzel sobre a resistência de união ao cisalhamento na interface esmalte dental/resina composta. Metodologia: As coroas de 60 dentes incisivos bovinos foram incluídas em resina acrílica e as superfícies vestibulares de esmalte foram planificadas e condicionadas com ácido fosfórico a 35 %. O sistema adesivo Single Bond (3M/ESPE) e de resina composta Z-250 (3M/ESPE) foram utilizados para fabricar restaurações cilíndricas de resina composta perpendiculares à superfície plana do esmalte condicionado. Para o teste de cisalhamento, os espécimes foram submetidos ao ensaio mecânico com cinzéis de 0,5 mm, 1,0 mm, 2,0 mm ou 3,0 mm de largura da parte ativa romba, em uma máquina de ensaio universal à velocidade de 0,5 mm/min. Os dados obtidos foram analisados por análise de variância e teste de Duncan ao nível de significância de 5 %. Resultados: As médias de resistência de união ao cisalhamento dos grupos testados foram: 0,5 mm - 19,66 MPa; 1,0 mm -18,78 MPa; 2,0 mm - 16,77 MPa; 3,0 mm - 16,06 MPa. Houve diferença estatisticamente significativa entre os grupos de 0,5 e 3,0 mm (P=0,045), com uma relação inversa entre resistência de união ao cisalhamento e largura do cinzel. Conclusão: Os resultados sugerem que a resistência de união ao cisalhamento sofre influência da largura do cinzel utilizado no ensaio.


Asunto(s)
Animales , Bovinos , Instrumentos Dentales , Resinas Compuestas , Ensayo de Materiales , Resistencia al Corte
13.
Rev. odonto ciênc ; 24(3): 249-253, July-Sept. 2009. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-873875

RESUMEN

Purpose: The aim of this article was to present the conceptual model and development of an oral health database for storage, organization, and recovery of data from dental clinical records of a university dental school. Method: This is a joint project of the Graduate Programs in Dentistry and in Computational Science of the Pontifical Catholic University of Rio Grande do Sul (PUCRS). During a period of three months in 2008, semi-structured interviews were conducted with the dental faculty of five clinical areas of the PUCRS Dental School (FO-PUCRS). Collected data were used to build the database language and architecture. Results: Conceptual, logical, and physical database models were developed, as well as the generation of a script in SQL (Structured Query Language). After generating the script, the tool Oracle SQL Developer (Oracle Corporation, Redwood Shores, CA, USA) was used to import and create the FO-PUCRS OHDB (Oral Health Database) implemented in the Oracle 10g, a relational database management system (RDBMS). Conclusion: The FO-PUCRS OHDB represents an important advancement towards automating the institutional operational demands and will contribute to organize the clinical and social information of the patient population for administrative, educational, and research purposes.


Objetivo: Este artigo teve como objetivo documentar o trabalho realizado em conjunto pelos Programas de Pós-Graduação em Odontologia (PPGO), e Ciência da Computação (PPGCC) da Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS), visando à construção de um ambiente de armazenamento, organização e recuperação de dados provenientes de prontuários odontológicos. Método: Durante 3 meses em 2008 foram realizadas entrevistas semi-estruturadas com docentes de cinco áreas de atendimento odontológico da Faculdade de Odontologia (FO-PUCRS) para análise e coleta de requisitos. Resultados: Com base nas informações obtidas neste processo, foram desenvolvidas as modelagens conceitual, lógica e física do banco de dados, bem como a geração de um script em SQL (Structured Query Language). Após a geração do script, foi utilizada a ferramenta Oracle SQL Developer (Oracle Corporation, Redwood Shores, CA, USA) para sua importação e criação do BDSB (Banco de Dados em Saúde Bucal) implementado no SGBD (Sistema Gerenciador de Banco de Dados) relacional Oracle 10g. Conclusão: A construção do BDSB junto ao PPGO-PUCRS representa um importante avanço em direção a automatização das demandas operacionais da organização, mas principalmente a exploração de uma fonte valiosa de conhecimento, rica em informações clínicas e sociais.


Asunto(s)
Bases de Datos Factuales , Registros Odontológicos , Salud Bucal
14.
Rev. odonto ciênc ; 23(4): 325-329, out.-dez. 2008. ilus, tab, graf
Artículo en Inglés | LILACS, BBO | ID: lil-500144

RESUMEN

Purpose: This study evaluated the influence of different methods of dentin surface pre-treatment on microtensile bond strength and failure mode of a single-bottle adhesive. Methods: Twenty-four third molars were embedded in acrylic resin and ground until exposure of occlusal dentin. Six groups were tested according to the dentin surface pre-treatment: G1) 35% phosphoric acid (pa) (positive control); G2) slurry of pumice + pa; G3) air-abrasion with 25μm-aluminum oxide + pa; G3) air abrasion with 50μm-aluminum oxide + pa; G5) air abrasion with sodium carbonate + pa; G6) no treatment (negative control). The adhesive Single Bond (3M-ESPE) was applied on the dentin surface and photoactivated before a 6mm-height composite restoration was built (Z250, 3M-ESPE). After storage in distilled water at 37ºC for 24h, all specimens (sectional area of 1mm²) were subjected to a microtensile bond strength test at a crosshead speed of 0.5mm/min. Results: Bond strength mean values (MPa) were: G1=29.28, G2=21.04, G3=21.66, G4=18.94, G5=19.90, and G6=19.03. Only G1 was statistically different from the other groups (ANOVA and Tukey's test, α=0.05). SEM images of the adhesive interface after rupture showed prevalence of mixed failure type (adhesive fracture between dentin and adhesive agent plus partial cohesive fracture in the composite restoration or dentin) for all groups but G6. Conclusion: The use of cleaning agents on dentin surface might not be necessary for adhesive procedures with dentin total acid-etching.


Objetivo: Este estudo avaliou a influência de diferentes métodos de pré-tratamento da superfície dentinária sobre a resistência de união à microtração e modo de falha de um sistema adesivo de frasco único. Metodologia: Vinte e quarto terceiros molares foram incluídos em resina acrílica e desgastados até exposição da dentina oclusal. Seis grupos foram testados de acordo com o pré-tratamento da dentina: G1) ácido fosfórico a 35% (pa) (controle positivo); G2) pasta de pedra- pomes + pa; G3) jateamento com óxido de alumínio 25μm + pa; G3) jateamento com óxido de alumínio 50μm + pa; G5) jateamento com carbonato de sódio + pa; G6) sem tratamento (controle negativo). O sistema adesivo Single Bond (3M-ESPE) foi aplicado na superfície dentinária e fotoativado antes da simulação de uma restauração de resina de 6mm de altura (Z250, 3M-ESPE). Após armazenamento em água destilada a 37ºC por 24h, todos os espécimes (área transversal de 1mm²) foram submetidos ao teste de microtração à velocidade de 0,5mm/min. Resultados: Os valores médios de resistência de união (MPa) foram: G1=29,28; G2=21,04; G3=21,66; G4=18,94; G5=19,90; e G6=19,03. Somente o G1 foi estatisticamente diferente dos demais grupos (ANOVA e teste de Tukey, α=0,05). A observação em MEV da interface adesiva após ruptura mostrou prevalência de falha do tipo mista (fratura adesiva entre dentina e agente adesivo associada à fratura coesiva parcial na restauração de resina ou dentina) para todos os grupos, exceto G6. Conclusão: O uso de agentes de limpeza na superfície dentinária pode não ser necessário para procedimentos adesivos com condicionamento ácido total da dentina.


Asunto(s)
Humanos , Recubrimientos Dentinarios/farmacología , Dentina , Resistencia a la Tracción
15.
Rev. odonto ciênc ; 23(4): 333-337, out.-dez. 2008. graf, ilus, tab
Artículo en Inglés | LILACS, BBO | ID: lil-500146

RESUMEN

Purpose: This in vitro study evaluated the radiopacity of impression materials using an indirect digital system. Methods: Samples of four polyvinyl siloxanes, one polyether, one polysulfide, and one irreversible hydrocolloid were fabricated with 1.0, 1.5, and 3.5mm-thickness. Three samples of different thickness were placed on the Digora optical plate and exposed. The optical density (pixels) was recorded in three areas resulting in a total of 360 measurements. Data were analyzed by 2-way ANOVA and Tukey tests (α=0.05). Results: Significant differences were observed among all materials and thicknesses tested (P<0.001). Irreversible hydrocolloid and polyether showed the lowest optical density. Polysulfide showed the highest optical density under all evaluated conditions. Conclusion: There was a significant difference in optical density for all impression materials tested. Composition changes are suggested to allow radiographic detection and improve safety during clinical use of impression materials.


Objetivo: Este estudo in vitro comparou a radiopacidade de materiais de moldagem usando um método radiográfico digital indireto. Metodologia: Amostras de quatro polivinil-siloxanos, um poliéter, um polissulfeto e um hidrocolóide irreversível foram confeccionadas com alturas de 1, 1,5 e 3,5mm. Três amostras das diferentes espessuras foram dispostas sobre uma placa óptica Digora e exposta. A densidade óptica (pixels) foi registrada em três diferentes áreas de cada amostra. Os dados foram analisados pelo teste de análise de variância de dois fatores e teste de Tukey (α=0,05). Resultados: Diferenças significantes foram observadas entre todos os materiais e espessuras testadas (P<0,001). O hidrocolóide irreversível e o poliéter apresentaram a menor densidade óptica. O polissulfeto apresentou a maior densidade óptica em todas as condições avaliadas. Conclusão: Há diferença significativa na densidade óptica dos materiais de moldagem avaliados. Alterações na composição são necessárias para facilitar a detecção destes materiais a fim de aumentar a segurança no uso clínico.


Asunto(s)
Técnicas In Vitro , Materiales de Impresión Dental/efectos adversos , Radiografía Dental Digital/métodos
16.
Acta odontol. venez ; 45(4): 524-527, dic. 2007. ilus
Artículo en Español | LILACS | ID: lil-630025

RESUMEN

El presente trabajo tiene por objetivo evaluar la respuesta de dientes pré-molares superiores sanos y preparados a través de la análisis cualitativo de la distribución y concentración de las tensiones, de la luz polarizada en modelos fotoelásticos de los mismos. Fueron creados modelos fotoelásticos con diferentes configuraciones de preparación cavitaria y esos cuerpos se sometieron a carga oclusal en maquina de ensayo universal asociado al polariscopio circular para el análisis de una distribución de las tensiones. Los resultados obtenidos demuestran que, en los dientes sanos, las tensiones están concentradas en el esmalte de la cúspide palatina, diferentemente de los modelos con preparaciones cavitarias donde la concentración de las tensiones se produjo en regiones diversas del modelo fotoelástico. La configuración cavitaria influye directamente en la distribución de las tensiones, pues cuan mayor sea la remoción de la estructura dentaría, peor será el comportamiento mecánico del remanente


The aim of this study was evaluate the behavior of upper first premolars with different cavity configurations using a qualitative analysis of distribution and stress concentration through polarized light in photoelastic models. Photoelastic models were created with different cavity preparations and these samples were submitted to oclusal stress using an universal testing machine associated to circular polariscope that analyzed the stress distribution. The results showed that stress is concentrated in enamel of palatal cuspid in sound teeth. Differently, in the prepared models, stress concentration occurred in different areas of the photoelasticity model. The cavity configuration has a direct influence on the stress distribution. As much tooth structure is removed, worst is the mechanical behavior of the reminiscent


O presente trabalho tem por objetivo avaliar a resposta de dentes pré-molares superiores hígidos e preparados através da análise qualitativa da distribuição e concentração das tensões através da luz polarizada em modelos fotoelásticos dos mesmos. Foram criados modelos fotoelásticos com diferentes configurações de preparo cavitário e esses corpos foram submetidos a carregamento oclusal em maquina de ensaio universal associado ao polariscopio circular para análise da distribuição das tensões. Os resultados obtidos demonstram que, nos dentes hígidos, as tensões estão concentradas no esmalte da cúspide palatina, diferentemente dos modelos com preparos cavitários onde a concentração das tensões se deu em regiões diversas do modelo fotoelástico. A configuração cavitária influencia diretamente a distribuição das tensões, pois quanto maior a remoção da estrutura dentária, pior se torna o comportamento mecânico do remanescente


Asunto(s)
Femenino , Preparación de la Cavidad Dental , Fracturas de los Dientes , Odontología
17.
Rev. odonto ciênc ; 22(58): 317-320, out.-dez. 2007. graf, tab
Artículo en Portugués | LILACS | ID: lil-487211

RESUMEN

O objetivo do presente estudo é comparar e avaliar a microdureza Vickers de um compósito restaurador microhíbrido ativado por dois tipos de unidades polimerizadoras e armazenados em água destilada. Trinta espécimes foram feitos com resina Charisma B1, para cada um dos regimes de polimerização: fotopolimerização por luz halógena, fotopolimerização por LED e fotopolimerização mais ciclo adicional em autoclave. Foram feitas duas leituras de microdureza Vickers por corpo de prova em 1 dia, 7 dias e 14 dias de imersões. O ciclo adicional de polimerização mostrou uma tendência de aumentar os valores de microdureza dos compósitos restauradores, não mostrando diferenças estatisticamente significantes entre LED e Luz Halógena (p > 0,05).


The purpose of this study is to evaluate and compare the Vickers microhardness of one microhybrid composite polymerized with different sources and stored in distilled water for up to 14 days. Thirty samples have been prepared with Charisma composite, shade B1, for each polymerization method: halogen light photopolymerization, LED photopolymerization, photopolymerization plus post-cured cycles in autoclave. Two readings of Vichers micro hardness have been done in each sample on 24h, 7days and 14 days of storage. The post curing method tended to improve the microhardness, but it was not statistically different from halogen or LED curing methods (p > 0.05). After 7 days, the hardness values were higher than the first day, but statistically not different to 14 days (p < 0.05). Post-cured samples in autoclave had an improved mean value, however, without differing from those of the LED and halogen.


Asunto(s)
Resinas Compuestas , Pruebas de Dureza
18.
Acta odontol. venez ; 45(2): 213-216, 2007. ilus, tab, graf
Artículo en Español | LILACS | ID: lil-499565

RESUMEN

Este estudio evaluó la influencia de diferentes métodos de tratamiento superficial de la cerámica Cergogold® (Degussa, Richmond, BC, Canadá) en la resistencia a la tracción a un cemento con base de resina. Cuarenta discos de cerámica prensada fueron confeccionados e incluidos en resina acrílica autopolimerizable. Cuatro diferentes grupos (n=10) fueron clasificados de acuerdo con el tratamiento: Grupo I: control (silano/sin acondicionamiento), Grupo II: microabrasión con óxido de aluminio (50 m), Grupo III: ácido fluorhídrico al 10 por ciento y Grupo IV: combinación de ácido fluorhídrico y microabrasión. Los resultados presentaron diferencias significativas entre los grupos: Grupo I (control) - x=3,89 MPa; Grupo II -x=7,8 MPa; Grupo III - x=5,6 MPa y Grupo IV - x=7,67 MPa, para lo cual se utilizó la prueba de ANOVA/Tukey (p<0,05). El grupo control presentó la media menor, seguido del grupo tratado con ácido fluorhídrico y, con mayor resistencia de unión, los grupos microabrasión y combinación de ambos. Se concluye que todos los tratamientos superficiales efectuados sobre la cerámica Cergogold® incrementaron la resistencia de unión a la tracción a un cemento con base de resina, lo que puede tener implicaciones clínicas de beneficio.


The number of children's cases that you suffer domestic violence is increasing now. The purpose of this study was to analyze the degree of knowledge of the Community Leaders on violence tames, the all is prepared to identify her; the knowledge on which they are the competent organs for the notification; and if, notifying the aggression, they are capable of being acting on behalf of the attacked child. They took place an interview structured with Community Leaders of the Child's Pastoral in the area west of the city of Londrina-PR. The results demonstrate: 56% of the interviewees are capable to identify the domestic violence, where the violence for them only corresponds to "beat in the child", and still 30% of them know that the organ is Guardian Council don't do him for fear of some type. It is ended that the need exists of being if making groups for explanations on the approached theme, trainings with the Leaders and meetings with the families.


Asunto(s)
Cementos de Resina/química , Cerámica/química , Propiedades de Superficie , Resistencia a la Tracción , Ácido Fluorhídrico/química , Grabado Ácido Dental/métodos , Ensayo de Materiales , Interpretación Estadística de Datos , Óxido de Aluminio/química
19.
RFO UPF ; 11(1): 61-64, 2006. ilus, tab, graf
Artículo en Portugués | LILACS, BBO | ID: lil-457211

RESUMEN

O objetivo deste estudo foi avaliar a resistência à tração diametral entre gessos tipo IV mineral e sintético. Foram confeccionadas trinta amostras a partir de uma matriz bipartida de teflon cilíndrica de 6mm de diâmetro e 3 mm e altura, com os materiais Vel Mix (kerr), Tuff Rock (Talladium) e Fuji Rock EP (GC Europe). Todos os materiais foram manipulados manualmente de acordo com as especificações dos fabricantes. Após a manipulação dos materiais para modelo, estes foram vazados na matriz sob vibração e armazenados por 24 horas. A seguir, os testes de tração diametral foram realizados numa máquina de ensaio universal (EMIC DL 2000), com velocidade de carregamento de 0,05 mm/min, no sentido de compressão até ocorrer a ruptura. A tensão máxima de fratura foi obtida em Newton (N) e transformada em Magapascal (MPa). Os dados foram submetidos ao teste de análise de variância e Tukey (p<0,05). Os resultados obtidos foram: Fuji Rock EP (8,48 MPz), Tuff Rock (7,91 MPa) e Vel Mix (5,09 MPa). A menor (5,09 MPa). A menor resistência à tração diametral foi verificada no grupo Vel Mix, já os grupos Tuff Rock e Fuji Rock EP apresentaram as maiores médias, no entanto não diferiram estatisticamente


Asunto(s)
Sulfato de Calcio , Resinas , Resistencia a la Tracción
20.
Rev. odonto ciênc ; 20(47): 3-10, jan.-mar. 2005. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-413482

RESUMEN

O objetivo deste estudo foi analisar os diferentes níveis de cinza de quatro resinas compostas micro-híbridas, através do sistema de radiografia digital direto Sens-a-Ray. As resinas utilizadas foram: Concept (Vigodent), Herculite (Sybron/Kerr), IntenS (Ivoclar Vivadent) e Z 100 (3MESPE), na cor A2. Foram confeccionadas 3 placas de acrílico para cada espessura 2, 3 e 4 mm que possuíam dimensões de um filme periapical. Em todas as placas foram feitos quatro orifícios eqüidistantes com 4 mm de diâmetro onde as resinas compostas foram inseridas, esses orifícios apresentavam 4 mm de diâmetro. As amostras foram radiografadas a 30 cm de distância foco-filme do sistema Sens-a-Ray por 0,8 segundo com aparelho de Raios-X (Dabi Atlante) de 70 kV e 10 mA. A quantidade dos níveis de cinza, das resinas, foi aferida em pixels pelo sistema Sens-a-Ray. Foram obtidas as seguintes médias: Concept - 2 mm com 79,6; 3mm com 85,4 e 4 mm com 96,7; Herculite - 2 mm com 65,1; 3 mm com 72,5 e 4 mm com 85,4; ItenS - 2 mm com 138,5; 3 mm com 147,3 e 4 mm com 153,7; Z 100 - 2 mm com 133,5; 3 mm com 143,8 e 4 mm com 150,6. Após os resultados foram submetidos ao teste estatístico ANOVA-Tukey com um nível de significância (p < 0,05), havendo diferença estatística entre as amostras (p > 0,05). A colorimetria foi utilizada para ilustrar a densidade óptica dos compósitos, com cores vermelho, verde e azul, representando, respectivamente do mais radiopaco para o menos radiopaco. Podemos concluir que na medida em que aumentou a espessura das placas os níveis de cinza também aumentaram. A resina Herculite apresentou os menores níveis de cinza, diferindo estatísticamente das demais. As resinas ItenS e Z 100 apresentaram maiores níveis de cinza que as demais


Asunto(s)
Humanos , Radiografía Dental Digital , Resinas Compuestas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA