Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Coluna/Columna ; 22(1): e262504, 2023. graf, il
Artículo en Inglés | LILACS | ID: biblio-1421316

RESUMEN

ABSTRACT Objectives: Evaluate the treatment outcome and the performance of the uCentum spinal fixation system in treating traumatic, degenerative, and tumoral diseases of the spine. Methods: This is a therapeutic study to investigate treatment outcomes and level of evidence III, including twenty-three adult patients of both sexes undergoing surgical treatment of degenerative (13 patients), traumatic (04 patients), or tumor diseases (06 patients). Patients were prospectively evaluated using clinical parameters: pain (visual analog scale), clinical and functional assessment questionnaires (SF-36, Oswestry and Roland-Morris), and radiological criteria (arthrodesis consolidation, loosening, breakage or deformation of the implants). Results: Twenty patients were followed for a period of 01 month to 12 month (mean 6,5±7,77). Three patients died due to complications unrelated to the primary disease (traumatic brain injury, septicemia, and lung tumor). Improvements were observed in clinical parameters and scores of the evaluation questionnaires used. No implant-related complications (breakage, loosening, deformation) were observed. Conclusion: the uCentum fixation system showed great versatility for performing the surgical treatment, allowing the performance of open, percutaneous procedures, the introduction of acrylic cement inside the implants, and conversion of polyaxial screws into monoaxial screws intraoperatively. Level of Evidence III; Therapeutic Studies - Investigating the Results of Treatment.


Resumo: Objetivos: Avaliar o resultado do tratamento e o desempenho do sistema uCentum de fixação vertebral no tratamento de doenças traumáticas, degenerativas e tumorais da coluna vertebral. Métodos: Trata-se de um estudo terapêutico de investigação dos resultados do tratamento e nível de evidência III, incluindo vinte e três pacientes adultos de ambos os sexos submetidos ao tratamento cirúrgico de doenças degenerativas (13 pacientes), traumáticas (04 pacientes) ou tumorais (06 pacientes). Os pacientes foram prospectivamente avaliados por meio de parâmetros clínicos: dor (escala visual analógica), questionários de avaliação clínica e funcional (SF-36, Oswestry e Roland-Morris), e critérios radiológicos (consolidação da artrodese, soltura, quebra ou deformação dos implantes). Resultados: vinte pacientes foram seguidos por um período de 01 a 12 meses (média 6,5 ± 7,77). Três pacientes foram a óbito devido a complicações não relacionadas com a doença primária (trauma cranioencefálico, septicemia e tumor pulmonar). Foi observada melhora dos parâmetros clínicos e escores dos questionários de avaliação utilizados. Não foram observadas complicações relacionadas com os implantes (quebra, soltura, deformação). Conclusão: o sistema de fixação uCentum apresentou grande versatilidade para a realização do tratamento cirúrgico, permitindo a realização de procedimentos abertos, percutâneos, introdução de cimento acrílico no interior dos implantes e conversão dos parafusos poliaxiais em monoaxiais no intra-operatório. Nível de Evidencia III; Estudos terapêuticos - Investigação dos resultados do tratamento.


Resumen: Objetivos: Evaluar el resultado del tratamiento y el desempeño del sistema de fijación vertebral uCentum en el tratamiento de enfermedades traumáticas, degenerativas y tumorales de la columna vertebral. Métodos: Este es un estudio terapéutico para investigar los resultados del tratamiento y el nivel de evidencia III, que incluye veintitrés pacientes adultos de ambos sexos sometidos a tratamiento quirúrgico de enfermedades degenerativas (13 pacientes), traumáticas (04 pacientes) o tumorales (06 pacientes). Los pacientes fueron evaluados prospectivamente mediante parámetros clínicos: dolor (escala analógica visual), cuestionarios de evaluación clínica y funcional (SF-36, Oswestry y Roland-Morris) y criterios radiológicos (consolidación de artrodesis, aflojamiento, rotura o deformación de los implantes). Resultados: veinte pacientes fueron seguidos durante un período de 1 a 12 meses (media 6,5 + 7,77). Tres pacientes fallecieron por complicaciones no relacionadas con la enfermedad primaria (lesión cerebral traumática, septicemia y tumor pulmonar). Se observaron mejoras en los parámetros clínicos y puntuaciones de los cuestionarios de evaluación utilizados. No se observaron complicaciones relacionadas con el implante (rotura, aflojamiento, deformación). Conclusión: el sistema de fijación uCentum mostró una gran versatilidad para realizar el tratamiento quirúrgico, permitiendo la realización de procedimientos abiertos, percutáneos, introducción de cemento acrílico en el interior de los implantes y conversión de los tornillos poliaxiales en tornillos monoaxiales en el intraoperatorio. Nivel de Evidencia III; Estudios terapéuticos - Investigación de los resultados del tratamiento.


Asunto(s)
Humanos , Masculino , Femenino , Fijación de Fractura , Procedimientos Ortopédicos
2.
Coluna/Columna ; 22(1): e262409, 2023. tab, graf, il
Artículo en Inglés | LILACS | ID: biblio-1421317

RESUMEN

ABSTRACT Objectives: Evaluate the reliability and reproducibility of the kyphosis measurement in thoracolumbar spine traumatic fractures by different assessment methods in different types of fractures. Methods: Fifteen fractures of the thoracolumbar spine, previously classified into types A, B, and C according to Magerl's classification, were evaluated. The value of kyphosis was measured using five different methods: (1) Cobb angle; (2) Gardner's method; (3) back wall method; (4) angle of adjacent endplates; and (5) wedge angle. The measurements were performed by five independent observers and repeated five times with a minimum interval of two weeks between each evaluation. Results: Intraobserver reliability was excellent among the five observers, evidencing good reproducibility of the methods. The five methods used also showed great intraobserver reliability in the global analysis, with methods one and four being more consistent. Conclusion: Although there is no universal agreement on measuring kyphosis in thoracolumbar fractures, our study concluded that method 1 (Cobb angle) and method 4 (adjacent endplate angle) presented the best interobserver reliabilities. Furthermore, the use of digitized radiographs and a simple computer program allowed the performance of highly reliable and reproducible measurements by all methods, given the high intraobserver reliability. Level of Evidence II; Comparative study.


Resumo: Objetivos: Avaliar a confiabilidade e reprodutibilidade da mensuração da cifose nas fraturas traumáticas da coluna toracolombar por diferentes métodos de avaliação nos diferentes tipos de fraturas. Métodos: Foram avaliadas 15 fraturas na coluna toracolombar previamente classificadas em tipo A, B e C de acordo com a classificação de Magerl. Em cada caso, foi medido o valor da cifose através de cinco diferentes métodos: (1) ângulo de Cobb; (2) método de Gardner; (3) método das paredes posteriores; (4) ângulo das placas terminais adjacentes; e (5) ângulo de cunha. As mensurações foram realizadas por cinco avaliadores independentes e repetidas cinco vezes com intervalo mínimo de duas semanas entre cada avaliação. Resultados: A confiabilidade intraobservador mostrou-se excelente entre os cinco avaliadores, evidenciando boa reprodutibilidade dos métodos. Os cinco métodos utilizados também apresentaram grande confiabilidade intraobservador na análise global, sendo mais consistentes o método 1 e o método 4. Conclusão: Apesar de não haver concordância universal em como medir a cifose nas fraturas toracolombares, nosso estudo concluiu que o método 1 (ângulo de Cobb) e o método 4 (ângulo das placas terminais adjacentes) apresentaram as melhores confiabilidades interobservadores. Além disso, o uso de radiografias digitalizadas e um programa computadorizado simples permitiram a realização de medidas altamente confiáveis e reprodutíveis por todos os métodos, visto pela elevada confiabilidade intraobservador. Nível de evidência II; Estudo Comparativo.


Resumen: Objetivos: Evaluar la fiabilidad y reproducibilidad de mensuración de cifosis en fracturas traumáticas de la columna toracolumbar por diferentes métodos de valoración en diferentes tipos de fracturas. Métodos: Se evaluaron quince fracturas de columna toracolumbar, previamente clasificadas en los tipos A, B y C según la clasificación de Magerl. En cada caso, el valor de la cifosis se midió utilizando cinco métodos diferentes: (1) ángulo de Cobb; (2) método de Gardner; (3) método de la pared posterior; (4) ángulo de placas de extremo adyacentes; y (5) ángulo de cuña. Las mediciones fueron realizadas por cinco evaluadores independientes y repetidas cinco veces con un intervalo mínimo de dos semanas entre cada evaluación. Resultados: La confiabilidad intraobservador fue excelente entre los cinco evaluadores, evidenciando una buena reproducibilidad de los métodos. Los cinco métodos utilizados también mostraron una gran fiabilidad intraobservador en el análisis global, siendo el método 1 y el método 4 más consistentes. Conclusión: Aunque no existe un acuerdo universal sobre cómo medir la cifosis en las fracturas toracolumbares, nuestro estudio concluyó que el método 1 (ángulo de Cobb) y el método 4 (ángulo de la placa terminal adyacente) presentaron las mejores confiabilidades entre observadores. Además, el uso de radiografías digitalizadas y un programa informático simple permitieron realizar mediciones altamente fiables y reproducibles por todos los métodos, dada la alta fiabilidad intraobservador. Nivel de evidencia II; Estudio Comparativo.


Asunto(s)
Humanos , Columna Vertebral , Intensificación de Imagen Radiográfica , Fracturas de la Columna Vertebral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA