Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
J. Bras. Patol. Med. Lab. (Online) ; 58: e4132022, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1375691

RESUMEN

ABSTRACT Introduction The classification of intestinal metaplasia by histochemistry methods has been described as the most appropriate. However, current algorithms are not replicable in laboratories due to severe limitations. Objective To evaluate a new algorithm to differentiate histochemical types of intestinal metaplasia. Material and Method: Cross-sectional research in which 512 gastric biopsies with intestinal metaplasia (paraffin blocks) were evaluated by a new algorithm using two types of Alcian Blue dyes during February-March of 2020 in the pathological anatomy service of the Maria Auxiliadora Hospital, Lima, Peru. This evaluation consisted of two steps: visualization of acid mucins in the columnar cells of the gastric mucosa and calculation of the weighted Kappa statistic. Results Histochemical types of intestinal metaplasia showed as follows: Type I, 398 (77.7%); Type II, 81 (15.8%) and Type III, 33 (6.5%). The weighted Kappa statistic was 0.79 (p<0.001), rated as an important or good concordance. Conclusion This new algorithm demonstrated it was useful and capable of identifying and differentiating the histochemical types of intestinal metaplasia, in addition to having statistical reliability.


RESUMO Introdução A classificação da metaplasia intestinal por métodos histoquímicos tem sido descrita como a mais adequada. No entanto, os algoritmos atuais não são replicáveis?? em laboratórios devido a limitações severas. Objetivo Avaliar um novo algoritmo para diferenciar tipos histoquímicos de metaplasia intestinal. Material e Método: Pesquisa transversal em que 512 biópsias gástricas com metaplasia intestinal (blocos de parafina) foram avaliadas por um novo algoritmo usando dois tipos de corantes Alcian Blue durante fevereiro-março de 2020 no serviço de anatomia patológica do Hospital Maria Auxiliadora, Lima, Peru. Essa avaliação consistiu em duas etapas: visualização das mucinas ácidas nas células colunares da mucosa gástrica e cálculo da estatística Kappa ponderado. Resultados Os tipos histoquímicos de metaplasia intestinal mostraram-se a seguir: Tipo I, 398 (77,7%); Tipo II, 81 (15,8%) e Tipo III, 33 (6,5%). A estatística Kappa ponderado foi de 0,79 (p <0,001), classificada como concordância importante ou boa. Conclusão Este novo algoritmo demonstrou ser útil e capaz de identificar e diferenciar os tipos histoquímicos de metaplasia intestinal, além de possuir confiabilidade estatística

2.
J. Bras. Patol. Med. Lab. (Online) ; 56: e1912020, 2020. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1134604

RESUMEN

ABSTRACT Introduction: Automated hematology analyzers are able to produce low platelet counts with great precision and accuracy. However, these analyzers may produce erroneous counts due to the presence of interferences. Therefore, additional methodologies are required to confirm platelet counts, such as blood smear and a direct count, using the Neubauer chamber. Objective: To validate the reliability estimate produced by the G&S method. Material and method: One hundred and fifty platelet counts were analyzed in the hematology and emergency laboratories of the Hospital Nacional Docente Madre-Niño San Bartolomé, in Lima, Peru, by four methodologies: one optical platelet count (PLTO), one indirect blood smear count (Indirect), and two direct counts (Direct and G&S). Descriptive and inferential statistics were used to compare the groups. Results: A significant difference was observed in the distribution of the four methodologies and, after applying the post-hoc analysis, a similarity between the PLTO and G&S methods was found. Also, the Direct, G&S and Indirect methods showed a positive correlation with the PLTO method. The Bland-Altman test demonstrated that the G&S method presented a high agreement with the PLTO method. Conclusion: The G&S method is inexpensive, easy to perform, and has demonstrated statistical reliability concerning the automated methodology, and is useful for confirming low platelet counts after a suspected error by the automated equipment or when this device is not available for use.


RESUMEN Introducción: Los analizadores automáticos hematológicos son capaces de realizar bajos recuentos de plaquetas con precisión y exactitud. Sin embargo, eses analizadores pueden producir recuentos erróneos debido a la presencia de interferencias. Así, métodos adicionales son necesarios para confirmar los recuentos de plaquetas, como el frotis de sangre y un recuento directo en cámara de Neubauer. Objetivo: Validar la confiabilidad de la estimación del método G&S. Material y método: Se analizaron ciento cincuenta recuentos de plaquetas en los laboratorios de hematología y emergencias del Hospital Nacional Docente Madre-Niño San Bartolomé, en Lima, Perú, por cuatro métodos: un recuento óptico de plaquetas (PLTO), un recuento indirecto por frotis de sangre (Indirecto) y dos recuentos directos (Directo y G&S). Se utilizaron estadísticas descriptivas e inferenciales para comparar los grupos. Resultados: Se observó diferencia significativa en la distribución de los cuatro métodos y, luego de la aplicación del análisis post-hoc, se encontró similitud entre los métodos PLTO y G&S. Además, los métodos Directo, G&S e Indirecto mostraron correlación positiva con el método PLTO. La prueba de Bland-Altman demostró que el método G&S presentó alta concordancia con el método PLTO. Conclusión: El método G&S es económico, fácil de llevar a cabo y demostró confiabilidad estadística en relación con el método automatizado, siendo útil para confirmar bajos recuentos de plaquetas después de una sospecha de error por el equipo automático o cuando el laboratorio no cuente con éste.


RESUMO Introdução: Os analisadores automatizados hematológicos são capazes de realizar baixas contagens de plaquetas com precisão e exatidão. No entanto, esses analisadores podem produzir contagens erradas devido à presença de interferências. Dessa forma, métodos adicionais são necessários para confirmar as contagens de plaquetas, como esfregaço de sangue e uma contagem direta, utilizando a câmara de Neubauer. Objetivo: Validar a confiabilidade gerada pela estimativa do método G&S. Material e método: Cento e cinquenta contagens de plaquetas foram analisadas nos laboratórios de hematologia e emergência do Hospital Nacional Docente Madre-Niño San Bartolomé em Lima, Peru, por quatro metodologias: uma contagem óptica de plaquetas (PLTO), uma contagem indireta por esfregaço de sangue (Indireto) e duas contagens diretas (Direto e G&S). Estatísticas descritivas e inferenciais foram utilizadas para comparar os grupos. Resultados: Observou-se diferença significativa na distribuição das quatro metodologias e, após a aplicação da análise post-hoc, obteve-se semelhança entre os métodos PLTO e G&S. Além disso, os métodos Direto, G&S e Indireto mostraram correlação positiva com o método PLTO. O teste de Bland-Altman demonstrou que o método G&S apresentou alta concordância com o método PLTO. Conclusão: O método G&S é barato, fácil de executar e demonstrou confiabilidade estatística em relação à metodologia automatizada, sendo útil para confirmar baixas contagens de plaquetas após uma suspeita de erro pelo equipamento automatizado ou quando não se tem esse aparelho disponível para uso.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA