Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Odovtos (En línea) ; 24(3)dic. 2022.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1406163

RESUMEN

Abstract This study evaluates the effect of curing modes and times on the mechanical properties of nanocomposites. Two nanocomposite resins were investigated: suprananohybrid (Estelite Posterior Quick; EP) and nanohybrid (Solare X; SX). They were polymerized with a light-emitting diode light-curing units (LED LCU, Valo) as follows: standard mode for 20s (ST20), high power mode for 12s (HP12), high power mode for 20s (HP20), extra power mode for 6s (XP6), and extra power mode for 20s (XP20). For Vickers microhardness (HV), disc-shaped specimens were fabricated (n=10). For the three-point bending test, bar-shaped specimens were fabricated (n=10). Flexural strength and resilience modulus were calculated. The fractured surfaces and specimen surfaces of composites were observed using scanning electron microscopy. The data were analyzed with repeated measures ANOVA, two-way variance, and Bonferroni tests (p<0.05). On the top and bottom surfaces of the EP nanocomposite resin, ST20 and HP12 revealed statistically higher HV than with XP6. Moreover, HP20 and XP20 had statistically higher HV than HP12 and XP6. For the SX nanocomposite resin, HP20 had statistically higher HV than HP12. For EP and SX, there were no significant differences in flexural strength and resilience modulus regarding the curing modes and times. Furthermore, SX demonstrated lower mechanical properties than EP. Scanning electron microscopy indicated that both nanocomposites had similar surface appearances. However, with all curing modes and times, SX exhibited layered fractures and more crack formations than EP. Different curing modes and times could influence the microhardness of nanocomposites.


Resumen Este estudio evalúa el efecto del modo y tiempo de fotocurado sobre las propiedades mecánicas de los nanocompuestos. Se investigaron dos resinas nanocompuestas: supra-nanohíbrida (Estelite Posterior Quick; EP) y nanohíbrida (Solare X; SX). Se polimerizaron con unidades de fotopolimerización de diodos emisores de luz (LED LCU, Valo) de la siguiente manera: modo estándar durante 20s (ST20), modo de alta potencia durante 12s (HP12), modo de alta potencia durante 20s (HP20) , modo extra power durante 6s (XP6) y modo extra power durante 20s (XP20). Para la microdureza Vickers (HV), se fabricaron especímenes en forma de disco (n=10). Para el ensayo de flexión de tres puntos, se fabricaron probetas en forma de barra (n=10). Se calcularon la resistencia a la flexión y el módulo de resistencia. Las superficies fracturadas se observaron mediante microscopía electrónica de barrido. Los datos se analizaron con ANOVA varianza de dos vías y pruebas de Bonferroni (p<0,05). En las superficies superior e inferior de la resina nanocompuesta EP, ST20 y HP12 revelaron un HV estadísticamente mayor que con XP6. Además, HP20 y XP20 tenían un HV estadísticamente más alto que HP12 y XP6. Para la resina nanocompuesta SX, HP20 tenía un HV estadísticamente más alto que HP12. Para EP y SX, no hubo diferencias significativas en la resistencia a la flexión y el módulo de resistencia con respecto al modo y tiempo de fotocurado. Además, SX demostró propiedades mecánicas inferiores que EP. La microscopía electrónica de barrido indicó que ambos nanocompuestos son similares en la superficie. Sin embargo, SX exhibió fracturas en capas y más formaciones de grietas que EP. Diferentes modos y tiempos de fotocurado podrían influir en la microdureza de los nanocompuestos.


Asunto(s)
Nanocompuestos , Curación por Luz de Adhesivos Dentales , Turquía
2.
Odovtos (En línea) ; 24(3)dic. 2022.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1406165

RESUMEN

Abstract This study investigated the shear bond strength (SBS) of a universal adhesive to enamel/dentin; 1) that had undergone radiotherapy (RT) and 2) that were readily restored and had undergone RT. Enamel and dentin surfaces were obtained from 90 intact human molars. They were randomly divided into six groups according to the presence and timing of irradiation (RT0:no radiotherapy/control, RT1:RT before restoration, RT2:RT after restoration groups) and adhesive application modes (etch&rinse/ER, self-etch/SE)(n=15). A universal adhesive and resin composites were applied. The radiotherapy protocol was conducted with 60 Gy. The SBS test was subjected (1mm/min) and failure type analysis was performed. The resin-enamel/dentin interfaces were examined. Data were statistically analyzed. For enamel and dentin, the presence and timing of irradiation did not significantly influence the SBS values (p>0.05). For enamel, significantly higher SBS values were obtained using etch&rinse mode than self-etch mode (p<0.05). The predominant failure was mixed type. Loss of enamel prisms and obliterated irregular dentinal tubules were found for the radiotherapy-treated specimens. Resin tags were clearer in the irradiated enamel treated with ER than SE. Irradiation with different timings did not influence the bond strength to enamel and dentin, negatively. Irrespective of radiotherapy, the etch&rinse mode caused higher bond strength to enamel than self-etch mode.


Resumen Este estudio investigó la fuerza de unión al cizallamiento (SBS) de un adhesivo universal al esmalte/dentina en piezas que se habían sometido a radioterapia (RT). Se obtuvieron superficies de esmalte y dentina de 90 molares humanos intactos. Se dividieron aleatoriamente en seis grupos según la presencia y el momento de la irradiación (RT0: sin radioterapia/control, RT1: RT antes de la restauración, RT2: RT después de la restauración considerando los modos de aplicación del adhesivo (n=15). Se aplicó un adhesivo universal y resinas compuestas. El protocolo de radioterapia se realizó con 60 Gy. Se sometió a la prueba adhesiva (1mm/min) y se realizó análisis del tipo de falla. Se examinaron las interfases resina-esmalte/dentina. Los datos fueron analizados estadísticamente. Para el esmalte y la dentina, la presencia y el momento de la irradiación no influyeron significativamente en los valores adhesivos (p>0,05). Para el esmalte, se obtuvieron valores adhesivos significativamente más altos utilizando el modo de grabado y enjuague que el modo de autograbado (p<0,05). La falla predominante fue de tipo mixto. Se encontró pérdida de prismas de esmalte y túbulos dentinarios irregulares obliterados en las muestras tratadas con radioterapia. La irradiación con diferentes tiempos no influyó negativamente en la fuerza de unión al esmalte ni a la dentina. Independientemente de la radioterapia, el modo de grabado ácido y enjuague provocó una mayor fuerza de adhesión al esmalte que el modo de autograbado.


Asunto(s)
Humanos , Radioterapia/efectos adversos , Turquía , Cemento Dental/efectos de los fármacos , Neoplasias de Cabeza y Cuello
3.
J. appl. oral sci ; J. appl. oral sci;28: e20190042, 2020. graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1056592

RESUMEN

Abstract Gap formation of composite resin restorations is a serious shortcoming in clinical practice. Polymerization shrinkage stress exceeds the tooth-restoration bond strength, and it causes bacterial infiltration within gaps between cavity walls and the restorative material. Thus, an intermediate liner application with a low elastic modulus has been advised to minimize polymerization shrinkage as well as gap formation. Objective: The purpose of this in vitro study was to assess gap formation volume in premolars restored with different bulk-fill composites, with and without a resin-modified glass-ionomer cement (RMGIC) liner, using x-ray micro-computed tomography (micro-CT). Methodology: Sixty extracted human maxillary premolars were divided into six groups according to bucco-palatal dimensions (n=10). Standardized Class II mesio-occluso-distal cavities were prepared. G-Premio Bond (GC Corp., Japan) was applied in the selective-etch mode. Teeth were restored with high-viscosity (Filtek Bulk Fill, 3M ESPE, USA)-FB, sonic-activated (SonicFill 2, Kerr, USA)-SF and low viscosity (Estelite Bulk Fill Flow, Tokuyama, Japan)-EB bulk-fill composites, with and without a liner (Ionoseal, Voco GmbH, Germany)-L. The specimens were subjected to 10,000 thermocycles (5-55°C) and 50,000 simulated chewing cycles (100 N). Gap formation based on the volume of black spaces at the tooth-restoration interface was quantified in mm3 using micro-computed tomography (SkyScan, Belgium), and analyses were performed. Data were analyzed using repeated-measures ANOVA and the Bonferroni correction test (p < 0.05). Results: The gap volume of all tested bulk-fill composites demonstrated that Group SF (1.581±0.773) had significantly higher values than Group EB (0.717±0.679). Regarding the use of a liner, a significant reduction in gap formation volume was observed only in Group SFL (0.927±0.630) compared with Group SF (1.581±0.773). Conclusion: It can be concluded that different types of bulk-fill composite resins affected gap formation volume. Low-viscosity bulk-fill composites exhibited better adaptation to cavity walls and less gap formation than did sonic-activated bulk-fill composites. The use of an RMGIC liner produced a significant reduction in gap formation volume for sonic-activated bulk-fill composites.


Asunto(s)
Humanos , Resinas Compuestas/química , Imagenología Tridimensional/métodos , Preparación de la Cavidad Dental/métodos , Materiales Dentales/química , Restauración Dental Permanente/métodos , Polimerizacion , Técnicas In Vitro , Ensayo de Materiales , Cementos de Resina , Análisis del Estrés Dental , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA