Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. j. med. biol. res ; 50(3): e5848, 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-839264

RESUMEN

This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current), the radiometric survey (leakage radiation) and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1) and remained stable for long (constant) and short (repeatability) intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer). The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators) for cells and small animal irradiation, especially in early research stages.


Asunto(s)
Animales , Dosis de Radiación , Radiometría/instrumentación , Calibración , Diseño de Equipo , Aceleradores de Partículas , Radiometría/métodos , Rayos X
2.
Braz. j. med. biol. res ; 48(7): 644-649, 07/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-751345

RESUMEN

Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.


Asunto(s)
Adulto , Humanos , Masculino , Citocinas/sangre , Infecciones por VIH/sangre , Linfoma Relacionado con SIDA/sangre , Linfoma de Células B/sangre , Linfoma de Células B/virología , Biomarcadores de Tumor/sangre , Bisexualidad , Estudios de Casos y Controles , Infecciones por VIH/inmunología , Homosexualidad , Inflamación/sangre , Inflamación/inmunología , Inflamación/virología , Activación de Linfocitos , Linfoma Relacionado con SIDA/inmunología , Linfoma de Células B/inmunología , Análisis Multivariante
3.
Braz. j. med. biol. res ; 46(1): 71-80, 11/jan. 2013. graf
Artículo en Inglés | LILACS | ID: lil-665802

RESUMEN

Gliomas are the most common and malignant primary brain tumors in humans. Studies have shown that classes of kaurene diterpene have anti-tumor activity related to their ability to induce apoptosis. We investigated the response of the human glioblastoma cell line U87 to treatment with ent-kaur-16-en-19-oic acid (kaurenoic acid, KA). We analyzed cell survival and the induction of apoptosis using flow cytometry and annexin V staining. Additionally, the expression of anti-apoptotic (c-FLIP and miR-21) and apoptotic (Fas, caspase-3 and caspase-8) genes was analyzed by relative quantification (real-time PCR) of mRNA levels in U87 cells that were either untreated or treated with KA (30, 50, or 70 µM) for 24, 48, and 72 h. U87 cells treated with KA demonstrated reduced viability, and an increase in annexin V- and annexin V/PI-positive cells was observed. The percentage of apoptotic cells was 9% for control cells, 26% for cells submitted to 48 h of treatment with 50 µM KA, and 31% for cells submitted to 48 h of treatment with 70 µM KA. Similarly, in U87 cells treated with KA for 48 h, we observed an increase in the expression of apoptotic genes (caspase-8, -3) and a decrease in the expression of anti-apoptotic genes (miR-21 and c-FLIP). KA possesses several interesting properties and induces apoptosis through a unique mechanism. Further experiments will be necessary to determine if KA may be used as a lead compound for the development of new chemotherapeutic drugs for the treatment of primary brain tumors.


Asunto(s)
Humanos , Apoptosis/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Diterpenos/farmacología , Glioblastoma/tratamiento farmacológico , Mikania/química , Línea Celular Tumoral , /efectos de los fármacos , /efectos de los fármacos , Diterpenos/aislamiento & purificación , Proteína Ligando Fas , Citometría de Flujo , Glioblastoma/enzimología , Glioblastoma/patología , Reacción en Cadena en Tiempo Real de la Polimerasa , Transducción de Señal , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA