Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Braz. dent. sci ; 24(3): 1-13, 2021. tab, ilus
Artículo en Inglés | BBO, LILACS | ID: biblio-1281321

RESUMEN

Objective: Evaluate the effect of four preparation designs, two ceramic materials, and two occlusion contact types on the stress distribution of ceramic veneer in upper central incisor. Material and methods: 3D-models were performed in the modeling software containing enamel, dentin, pulp, periodontal ligament and a base of polyurethane resin. The designs were modeled and exported to the computer aided engineering software to perform the static structural analysis. For the mesh, a total of 155429 tetrahedron elements and 271683 nodes were used, after a 10% convergence test. Two materials, lithium disilicate and feldspathic ceramics, were simulated. A static load of 100 N on 45º was applied on the incisal and middle thirds of the palatal tooth region, guided by the occlusal plane. The base was constrained in all directions. The Maximum Principal Stress was the failure criteria chosen for the analysis. Results:The Finite Element Analysis showed that the most conservative designs presented less stress concentration on the ceramic veneer. However, the highest tensile stress concentrations were observed on lithium disilicate veneer with extend design, on the middle third. The type of occlusal contact presented different stress patterns among the preparation designs; the incisal contact showed higher stress concentration compared to middle third contact regardless the ceramic material. Conclusion: To perform a ceramic veneer in upper central incisor, the feldspathic ceramic presented promising results and should be recommended when the extended design was done. Regarding contact types, the incisal contact is more prone to failure regardless the ceramic and preparation design. (AU).


Objetivo: Avaliar o efeito de quatro desenhos de preparo, dois materiais cerâmicos e dois tipos de contato oclusais na distribuição de tensão de laminado cerâmico em incisivo central superior. Material e métodos: Modelos 3D foram realizados em software de modelagem contendo esmalte, dentina, polpa, simulador de ligamento periodontal e uma base de resina de poliuretano. Os desenhos foram modelados e exportados para o software de engenharia para realizar análise estatística estrutural. Para a malha, foram usados um total de 155429 elementos tetraedros e 271683 nós, após teste de convergência de 10%. Dois materiais, dissilicato de lítio e cerâmica feldspática, foram simulados. Uma carga estática de 100N em 45º foi aplicada no terço incisal e médio na região palatina do dente, guiada pelo plano oclusal e a base foi restringida em todas as direções. A tensão de tração foi o critério de falha escolhido para a análise. Resultados: A análise de elementos finitos mostrou que os desenhos mais conservadores apresentaram menor concentração de tensão no laminado cerâmico. Contudo, as maiores concentrações de tensões foram observadas no laminado de dissilicato de lítio com preparo estendido no terço médio. O tipo de contato oclusal apresentou diferentes padrões de tensões entre os diferentes desenhos, o contato incisal mostrou maior concentração de tensão em relação ao contato do terço médio independentemente do material cerâmico Conclusão: Para a confecção de laminado cerâmico em incisivo central superior, a cerâmica feldspática apresentou resultados promissores e é recomendada quando for feito preparo estendido. Em relação aos tipos de contato, o contato incisal é mais sujeito a falhas independentemente da cerâmica e desenho do preparo. (AU)


Asunto(s)
Cerámica , Análisis de Elementos Finitos , Coronas con Frente Estético
2.
Braz. dent. sci ; 22(3): 387-394, 2019. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-1009537

RESUMEN

Objective: The masticatory function is one of the most complex neuropsychological mechanisms in human motor performance and it depends on several factors, such as bite force, muscle coordination, morphology, and number of teeth in occlusion. To evaluate the influence of different rehabilitation treatments such as complete and partial dentures, masticatory forces, and the dynamics of mandibular elevator muscles. Material and Methods: the maximum bite force (force transducer) and electrical activity (superficial electromyography) associated with the masseter and temporal muscles were quantified. These factors were evaluated at rest position and isometric contraction. The data were subjected to descriptive statistics and compared based on the experimental groups, through ANOVA and Tukey's tests. Results: for bite force, the ANOVA test showed statistical difference between groups and Tukey's test showed that the force measured in the removable partial dentures group was 44.75% lower than that of the control group, while for complete denture wearers, there was a reduction of 74.4% in bite force in relation to the control group. For electromyographic activity, there was no statistical difference between groups. Pearson's correlation test (α = 5%) showed positive correlation between the variables of bite force and electromyographic activity only for the control group. Conclusion: it was concluded that the loss of dental elements and their replacement with either partial or complete dentures has a great influence on bite force and electromyographic activity of the masseter and temporal muscles. (AU)


Objetivo: A função mastigatória é um dos mecanismos neuropsicológicos mais complexos no desempenho motor humano e depende de vários fatores, como força de mordida, coordenação muscular, morfologia e número de dentes na oclusão. Avaliar a influência de diferentes tratamentos de reabilitação, como próteses totais e parciais, forças mastigatórias na dinâmica dos músculos elevadores da mandíbula. Material e Métodos: quantificaramse a força máxima de mordida (transdutor de força) e a atividade elétrica (eletromiografia superficial) associadas aos músculos masseteres e temporais. Esses fatores foram avaliados na posição de repouso e contração isométrica. Os dados foram submetidos à estatística descritiva e comparados com base nos grupos experimentais, através dos testes ANOVA e Tukey. Resultados: para força de mordida, o teste ANOVA mostrou diferença estatística entre os grupos e o teste de Tukey mostrou que a força medida no grupo próteses parciais removíveis foi 44,75% menor que a do grupo controle, enquanto para os usuários de prótese total houve redução 74,4% na força de mordida em relação ao grupo controle. Para a atividade eletromiográfica, não houve diferença estatística entre os grupos. O teste de correlação de Pearson (α = 5%) mostrou correlação positiva entre as variáveis força de mordida e atividade eletromiográfica apenas para o grupo controle. Conclusão: concluiu-se que a perda de elementos dentais e sua substituição por próteses parciais ou totais têm grande influência na força de mordida e na atividade eletromiográfica dos músculos masseteres e temporais. (AU)


Asunto(s)
Rehabilitación , Fuerza de la Mordida , Dentadura Completa , Electromiografía
3.
Braz. dent. sci ; 22(2): 220-227, 2019. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-996765

RESUMEN

Objective: To measure the intensity of muscle strength and electrical activity of masseter and anterior temporal muscles based on BTX-A therapy in patients rehabilitated with total prostheses on zygomatic implants. Material and Methods: The object of the study was a sample of 20 individuals subjected to zygomatic implant surgery and rehabilitated with implant-supported prostheses, in order to obtain electromyographic data using an eight-channel module (EMG System do Brasil). The data were collected for three consecutive months: prior to the application (single dose) of BTX-A (30 U/ masseter muscle; 10 U/temporal muscle) and after 30 and 90 days of therapeutic treatment. Result: All muscle groups studied showed reduction of muscle electrical activity during voluntary contraction after 30 days of treatment (around 47%) (p < 0.001), which progressively reverted after 90 days of treatment. The anterior temporal muscles presented similar motor behavior, with activity reduction of 39% (p < 0.05). There was a reduction of 17.68% (p < 0.05) in mandibular force and an increase of 14.22% (p < 0.05) in mouth opening after 30 days of BTX-A administration. Conclusions: The results suggest that BTX-A significantly reduces muscle activity, in either the recruitment of motor units or muscle tone, in the first three months of therapeutic treatment. This therapy may also be useful as a preventive method for the failure of zygomatic implant-supported prostheses. (AU)


Objetivo: Medir a intensidade da força muscular e atividade elétrica dos músculos temporal anterior e masseteres em função da terapia com BTX-A em pacientes reabilitados por próteses totais sobre implantes zigomáticos. Material e Métodos: Uma amostra composta por 20 indivíduos submetidos à cirurgia de implantes zigomáticos e reabilitados com próteses implantossuportadas foi objeto de estudo para obtenção de dados eletromiográficos utilizando um módulo de oito canais (EMG System do Brasil). Os dados foram coletados por três meses consecutivos: antes da aplicação (dose única) de BTX-A (30U / masseter muscular; 10U / temporal), após 30 e 90 dias do tratamento terapêutico. Resultados: Todos os grupos musculares estudados apresentaram redução da atividade elétrica muscular durante a contração voluntária, após 30 dias de tratamento (em torno de 47%) (p < 0,001), e revertidos progressivamente após 90 dias de tratamento. Os temporais anteriores apresentaram comportamento motor semelhante, apresentando redução de atividade de 39% (p < 0,05). Foi observada uma redução de 17,68% (p < 0,05) na força mandibular, assim como um aumento na abertura bucal de 14,22% (p < 0,05) após 30 dias da administração da BTX-A. Conclusões: Os resultados sugerem que a BTX-A reduz significativamente a atividade muscular, seja no recrutamento de unidades motoras ou no tônus muscular, nos primeiros três meses de tratamento terapêutico e pode ser útil como método preventivo de falha de prótese suportada por implantes zigomáticos.(AU)


Asunto(s)
Humanos , Toxinas Botulínicas , Implantes Dentales , Prótesis Dental de Soporte Implantado , Electromiografía
4.
Braz. dent. sci ; 19(1): 88-95, 2016. tab, ilus
Artículo en Inglés | LILACS, BBO | ID: lil-785292

RESUMEN

Objetivo: Este estudo se propôs avaliar o efeito de diferentes tempos de secagem de dois adesivos tipo ‘total-etch & rinse’ e ciclagem térmica na resistência adesiva entre cerâmica feldspatica e cimento resinoso. Material e Métodos: Trinta e dois blocos (12×10×4 mm) de cerâmica feldspática e respectivos blocos (32) de resina composta foram obtidos. A superfície de cimentação de cada bloco cerâmico foicondicionada por ácido fluorídrico (HF), silanizada (S), e recebeu a aplicação de um dos dois sistemas adesivos testados (SB - Single Bond 2, 3M-ESPE; ou PB – Prime & Bond NT, Dentsply). Então a superfície com o adesivo foi seca em diferentes tempos (5, 10 e 15s) antes da cimentação. Após, um cimento resinoso foi aplicado sobre a superfície de cimentação e o bloco correspondente de resina foi cimentado. Os palitos para microtração foram obtidos, sendo que metade deles foram imediatamente testados, enquanto os demais foram submetidos à ciclagem térmica e armazenagem (150 dias). Para os grupos sem envelhecimento, o tempo de secagem mais longo (15s) aumentou a resistência para o adesivo SB, enquanto que reduziu a resistência para o adesivoPB. Resultados: Para os grupos envelhecidos, as resistências adesivas dos diferentes tempos de secagem não foram diferentes estatisticamente, independente do adesivo. A falha predominante foi coesiva do cimento resinoso, seguido pela falha na interface cerâmica cimento. Conclusão: Conclui se que tempos mais longos de secagem podem melhorar a resistência adesiva à cerâmica testada, usando o adesivo SB. Por outro lado, tempos mais curtos podem otimizar a adesão para o adesivo PB. O envelhecimento afetou a adesão somente nos grupos do adesivo SB


Objective: This study evaluated the effect of drying times of two total-etch & rinse adhesives on the resin bond strength to a feldsphatic ceramic, before and after aging. Material and Methods:Feldsphatic-ceramic CAD-CAM bars were cut into blocks (12×10×4 mm) with a cutting machine (N = 32). Impressions were made of each ceramic block with silicone putty material and the negativespace was filled with a composite resin. The bonding ceramic surface was etched with hydrofluoric acid, silanized, and the adhesive system (SB- Single Bond 2, 3M-ESPE; or PB- Prime & Bond NT, Dentsply) was applied. The samples were dried at different times (5, 10 and 15 s) before the cementation. The resin and ceramic blocks were cemented bya dual cure resin cement. All samples were stored in distilled water at 37 °C for 24 h. For the μ-TBS test, the samples were sliced into microbars. Half of the bars of each block was tested after 24 h and, the other bars were submitted to thermocycling (12,000×) and water storage (150 d). For the 24 h groups, the longer drying time increased (p < 0.05) the bond strength of SB (water/alcohol adhesive), while reduced (p < 0.05) for the PB group (acetone based adhesive). Results: For the aged groups, the bond strength for the different drying times had no significant difference, for the both adhesives. Conclusion: Longer drying times increased the bond strength values of SB. Smaller drying times increased the bond strength values of PB. The aging protocol influenced the bond strength of SB groups.


Asunto(s)
Materiales Dentales , Cementos de Resina
5.
Braz. dent. sci ; 19(2): 89-95, 2016. ilus
Artículo en Inglés | LILACS | ID: lil-788619

RESUMEN

Evaluate the microtensile bond strength of a total-etch adhesive to dentin, using a CVD tipor diamond bur for dentin preparation and varying the etching time. Material and Methods: The dentin from the buccal surface of sixty bovine teeth was exposed and prepared using two different methods(n = 30): Group 1 (DB) – a diamond bur on a high-speed hand piece; and Group 2 (CVD) – a CVDtip on an ultrasonic hand piece. Each group used37% phosphoric acid and was divided into three subgroups, according to the etching time (n = 10):Subgroup 5s - 5 seconds; Subgroup 10s - 10 seconds; and Subgroup 15s - 15 seconds. Teeth were restored with Single Bond adhesive and the composite resin Herculite Classic. The specimens were subjected to thermo mechanical wear (mechanical cycling/100.000 cycles, thermal cycling/1.000cycles). Stick-like specimens were obtained and submitted to a microtensile test in a universal testing machine. Data (MPa) were analyzed by two-way ANOVA (Surface treatment X Etching time) andTukey’s test (5%). Results and Conclusion: Surface treatment with CVD tips (27.70 ± 4.04a) produced significantly higher bond strength values compared to diamond burs (23.96 ± 5.83b), and 5 s etching time on dentin produced similar bond strength values when compared to 10 and 15 s etching times...


Objetivo: avaliar a força de união de um adesivo convencional à dentina, usando pontas diamantadas e pontas CVD para preparo dentinário e variando o tempo de condicionamento ácido a dentina. Material e Métodos: A dentina da superfície vestibular de 60 dentes bovinos foi exposta e preparada usando dois diferentes métodos (n=30): Grupo 1 (DB) – ponta diamantada tradicional para alta rotação; e Grupo 2(CVD) – ponta CVD montada em ultrassom. Cada grupo foi dividido em três subgrupos, de acordo com o tempo de condicionamento ácido (n=10): Subgrupo 5s - 5 segundos; Subgrupo 10s - 10 segundos; e Subgrupo 15s- 15 segundos. Os dentes foram restaurados com adesivo convencional Single Bond e resina composta Herculite Classic. As restaurações foram submetidas à ciclagemtermo-mecânica (ciclagem mecânica/100.000 ciclos,ciclagem térmica/1.000 ciclos). Palitos foram obtidos e submetidos ao teste de microtração na máquina de ensaios universal. Os dados (MPa) foram analisados por ANOVA dois-fatores (Tratamento de superfície X condicionamento) e teste de Tukey (5%). Resultado e Conclusão: O tratamento de superfície com pontas CVD (27.70 ± 4.04a) resultaram em valores de adesão significantemente maiores quando comparados com as pontas diamantadas (23.96 ± 5.83b), e 5 segundos de condicionamento ácido sobre a dentina produziu valores similares de adesão quando comparado aos tempos de 10 e 15 segundos de condicionamento...


Asunto(s)
Humanos , Cementos Dentales , Dentina , Capa de Barro Dentinario
6.
Braz. dent. j ; 26(5): 478-483, Oct. 2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-767622

RESUMEN

Abstract: The aim of this study was to evaluate the effect of different polishing protocols on surface roughness and morphology of lithium disilicate ceramics (IPS e.max CAD). Fifty ceramic bars (2.0x3.0x2.5 mm) were produced and randomly divided into five groups (n=10), according to surface treatments: C: Control; Cer: Ceramaster (60 s); CW: cloth wheel with large-grit diamond (30 s) + cloth wheel with fine-grit diamond paste (30 s); E: grey Exa-Cerapol (20 s) + pink Exa-Cerapol (20 s) + Cerapol Super (20 s); F: Felt wheel with large-grit diamond paste (30 s) + Felt wheel with fine-grit diamond paste (30 s). The samples were evaluated quantitatively for surface roughness (Ra) and qualitatively by SEM, at different moments: initial (prior to roughening), after roughening and after polishing procedures. Ra means were submitted to two-way ANOVA and Tukey test (p<0.05). After the different polishing protocols, no statistically significant differences were observed between the Cer and E groups (p=0.6347), E and CW groups (p=0.1366), and CW and FW groups (p=0.5433). Comparing different stages in the same group, it was possible to observe that CW (p<0.0001) and FW groups (p<0.0001) showed significant differences. SEM analysis revealed that both Cer and E groups exhibited a surface morphological pattern similar to that of control group. All polishing systems were effective in reducing the surface roughness of the studied ceramic type.


Resumo: O objetivo deste estudo foi avaliar o efeito de diferentes protocolos de polimento sobre a rugosidade e morfologia superficial de uma cerâmica à base de dissilicato de lítio (IPS e.max CAD). Foram confeccionadas 50 barras cerâmicas (2,0x3,0x2,5 mm), separadas aleatoriamente em cinco grupos (n=10), conforme os tratamentos de superfície: C: Controle; BC: Borracha Ceramaster (60 s); RP: Roda de pano impregnado granulação grossa (30 s) + Roda de pano impregnado granulação fina (30 s); BE: Borracha Exa-Cerapol cinza (20 s) + Borracha Exa-Cerapol rosa (20 s) + Borracha Cerapol Super (20 s); RF: Roda de feltro com pasta diamantada grossa (30 s) + roda de feltro com pasta diamantada fina (30 s). As amostras foram avaliadas quantitativamente quanto à rugosidade superficial (Ra) e qualitativamente em MEV, em diferentes momentos: inicialmente (antes da asperização), após asperização e após os polimentos. As médias de Ra foram submetidas aos testes estatísticos ANOVA (two-way) e Tukey (p<0,05). Após os diferentes protocolos de polimento, não foi possível observar diferenças significativas entre os grupos BC e BE (p=0,6347), entre BE e RP (p=0,1366) e RP e RF (p=0,5433). Comparando as diferentes etapas de um mesmo grupo foi possível observar que os grupos RP (p<0,0001) e RF (p<0,0001) apresentaram diferenças significativas. Em MEV, os grupos BC e BE apresentam um padrão morfológico superficial semelhante ao grupo controle. Todos os sistemas de polimento foram efetivos na redução da rugosidade de superfície para o mesmo padrão de cerâmica.


Asunto(s)
Cerámica , Pulido Dental , Porcelana Dental/química , Propiedades de Superficie
7.
PróteseNews ; 2(4): 470-482, out.-dez. 2015. ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-846771

RESUMEN

Este trabalho teve como objetivo levar o leitor a uma revisão da literatura sobre os diferentes métodos de afastamento gengival, suas técnicas, indicações e contraindicações. Foram abordadas as variações dos métodos e técnicas, a fim de facilitar a escolha mais adequada às diferentes situações clínicas. São feitas considerações sobre as soluções químicas, os fios utilizados para o afastamento gengival, as pastas adstringentes, bem como a combinação entre eles. Foram elaborados quadros comparativos entre os diferentes métodos de afastamento gengival, entre as soluções químicas mais utilizadas e entre as diferentes marcas comerciais existentes.


This paper aims to take the reader on a review of literature about the diff erent methods of gingival retraction, their techniques, indications and contraindications. Variations of the methods and techniques were discussed in order to facilitate the most appropriate choice for diff erent clinical situations. Some considerations were made about the chemical solutions, the gingival retraction cords, as well as their combination. Comparative tables among the diff erent gingival retraction methods, the most used chemical solutions, and the diff erent trademarks were prepared.


Asunto(s)
Humanos , Técnica de Impresión Dental , Prótesis Dental , Encía/cirugía , Periodoncia
8.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, ilus
Artículo en Inglés | LILACS | ID: lil-777170

RESUMEN

The purpose of this study was to investigate the effect of CPP-ACP treatment and Nd:YAG laser on microtensile bond strength (µTBS) of softened dentin. Sixty samples were obtained from thirty sound third molars. All samples were submitted to dentin softening procedure, by the immersion of the specimens in 30 mL of Sprite Zero for 30min. Afterwards, the samples were randomly divided according to the CPP-ACP treatment: CG-Control group; MP-treated with CPP-ACP paste (MI Paste); MPP-treated with CPP-ACP+900 ppm NaF paste (MI Paste Plus). Each group was further divided according to bonding procedure: NL-No laser; L–Laser irradiation after adhesive application and before polymerization. The laser parameters used were 1.4 W, 10 Hz, 140 mJ/pulse, with an optic fiber of 320 µm, generating energy of 174 J/cm2 per pulse. All samples were restored with Clearfil SE Bond/Filtek Z350 XT. After 24 h, the restored samples were cut into beams (± 1 mm2adhesive interface area) and subjected to a µTBS test. Data were analyzed by two-way ANOVA test and Holm-Sidak post-hoc method (α = 0.05). The treatment with CPP-ACP pastes did not significantly affect softened dentin µTBS (p = 0.070). Statistic revealed significant reduction on µTBS values for CG/L, leading to the rejection of the second null hypothesis (p < 0.001). Both CPP-ACP based pastes did not affect µTBS of softened dentin for the adhesive system utilized. The Nd:YAG laser irradiation after application of adhesive system did affect µTBS values of softened dentin samples untreated with CPP-ACP based pastes.


Asunto(s)
Humanos , Caseínas/química , Quelantes/química , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Dentina/efectos de los fármacos , Dentina/efectos de la radiación , Láseres de Estado Sólido , Análisis de Varianza , Resinas Compuestas/química , Fracaso de la Restauración Dental , Inmersión , Ensayo de Materiales , Distribución Aleatoria , Reproducibilidad de los Resultados , Cementos de Resina/química , Estadísticas no Paramétricas , Factores de Tiempo , Resistencia a la Tracción/efectos de los fármacos , Resistencia a la Tracción/efectos de la radiación
9.
Artículo en Portugués | LILACS | ID: lil-724209

RESUMEN

Objetivo: Avaliar a liberação de íon fluoreto de 2 cimentos de ionômerode vidro (CIV) anidro e 2 modificados por resina composta antes e apósrecarga com fluoreto de sódio neutro a 2% por 4min. e após a proteçãoda superfície do CIV Maxxion R com um adesivo odontológico, umverniz cavitário e um esmalte incolor para unhas.Métodos: Com uma matriz de aço inox com 2mm x 6mm,confeccionou-se 5 corpos de prova de cada material, que foramimersos em 5mL de água deionizada, trocada a cada 24h. Foramrealizadas leituras em um potenciômetro nos dias 1, 2, 9 e 17 na 1ª e 2ªetapas, e as amostras foram tamponadas com solução TISAB III. Na 2ªetapa, as amostras foram submetidas à recarga e novamente imersasem 5mL de água deionizada. Na 3ª etapa foi realizada a proteção dasuperfície dos CIVs e feitas leituras nos 5min., 24h, 48h e 72h. Utilizouseos testes estatísticos Post Hoc de Tukey e t Student (p<0,05).Resultados: Observou-se diferença estatisticamente significante aocomparar a 1ª com a 2ª etapas em todos os materiais, exceto no dia 2para o Vidrion R e para o VitroFil LC. Na 3ª etapa observou-se que emtodos os materiais, comparando os primeiros 5 min. com os outrostempos, as diferenças entre as médias da liberação das concentraçõesde íon fluoreto foram estatisticamente significantes. Ao 0comparar osdemais tempos, tanto o verniz quanto o esmalte incolor para unhasapresentou diferença estatisticamente significante entre 24h e 48h,bem como em 24h e 72h.Conclusão: Os CIVs anidros tiveram maior efetividade na liberação deíon fluoreto e na recarga em comparação com os CIVs modificados porresina composta e o Maxxion R apresentou um comportamentohomogêneo e estatisticamente significante nas duas etapas. Todos osmateriais protetores testados foram eficazes, e o esmalte incolor paraunhas apresentou o melhor comportamento...


Objective: To evaluate fluoride ion release from two anhydrous glassionomer cements (GICs) and two resin-modified GICs (RMGICs) before and after recharge with 2% neutral sodium fluoride for 4 min and after surface protection of the Maxxion R GIC with an adhesive system, a cavity varnish and a colorless nail polish. Method: A stainless steel 2x6 mm matrix was used for fabricating 5 specimens of each material, which were immersed in 5 mL of deionized water, renewed every 24 h. Measurements with a potentiometer were performed on days 1, 2, 9 and 17, in the 1st and 2nd phases, and thespecimens were buffered with a TISAB III solution. In the 2nd phase, thespecimens were subjected to recharge and immersed again in 5 mL ofdeionized water. In the 3rd phase, the GIC surfaces were protected andreadings were made at 5 min, 24 h, 48 h and 72 h. TukeyÆs post-hoc and StudentÆs t tests were used for statistical analyses (p<0.05). Results: There was statistically significant difference in the comparison between the 1st and 2nd phases for all materials, except at day 2 for Vidrion R and VitroFil LC. In the 3rd phase, it was observed that for all materials, comparison of the first 5 min with the other times revealedstatistically significant differences among the means of fluoride ionrelease. In the comparison with the other times, both the varnish and the colorless nail polish presented statistically significant differencebetween 24 and 48 h as well as between 24 and 72 h. Conclusion: The anhydrous GICs were more effective in fluoride ion release and recharge compared with the RMGICs. Maxxion R presented a homogeneous and statistically significant behavior in both phases. All materials for surface protection were efficient and the colorless nail polish had the best behavior...


Asunto(s)
Humanos , Cementos de Ionómero Vítreo/química , Fluoruros , Materiales Dentales , Potenciometría/métodos , Resinas Compuestas/química , Interpretación Estadística de Datos
10.
Braz. dent. sci ; 16(1): 73-79, 2013. tab, ilus
Artículo en Inglés | LILACS, BBO | ID: lil-698281

RESUMEN

Objective: The aim of this study was to compare the bond strength of two self-etching adhesive systems with different types of dentin abrasion. Methods: Thirty two sound human molars were selected and had the dentin surface exposed and flattened. Tooth were randomly divided into four experimental conditions, according with the adhesive system [Clearfil SE Bond (SE) and One-Up Bond F(ONE)] and the type of dentin abrasion [conventional diamond bur (D) and ultrasound diamond bur (CVD)]. The adhesives were applied following manufactures’ instructions and light cured composite blocks of 4mm height were placed over dentin. After storage in distilled water for 24 h in 37 ºC, serial cuts were made on mesio-distal and buccal-lingual direction, obtaining specimens with stick format, with cross section of 8mm². The microtensile test was performed at a crosshead speed of 0.5 mm/min and load cell of 10kg, until failure. Data were submitted to ANOVA-2-Way followed by Tukey test (5%). Results: The results (MPa) were: D/ SE: 24.06 ± 8.84, D/ONE:15.03 ± 8.61, CVD/SE: 39.90 ± 8.24 and CVD/ONE:15.03 ±8.61. It can be concluded that the adhesive system Clearfil SE Bond showed higher bond strength related with the abrasion with CVD; the type of dentin abrasion interfered on the performance of Clearfil SE Bond but did not influence the One-Up Bond F results


Objetivo: O objetivo desta pesquisa foi comparar a resistência de união de dois sistemas adesivos autocondicionantes com diferentes métodos de preparo da dentina. Métodos: Foram utilizados 32 molares humanos hígidos extraídos, sendo que a superfície dentinária oclusal foi exposta e planificada. Os dentes foram aleatoriamente divididos em quatro diferentes condições experimentais de acordo com o sistema adesivo: Clearfil SE Bond (SE) ou One- Up Bond F (ONE) e com o método de preparo da dentina: ponta diamantada em alta rotação (D) ou ponta diamantada em ultra-som (CVD). Os adesivos foram aplicados de acordo com as recomendações do fabricante e foram confeccionados blocos de 5mm de altura de resina composta fotopolimerizável, pela técnica incremental. Após estocagem em água destilada por 24 h a 37 ºC, foram realizadas secções seriadas no sentido mésio-distal e vestíbulo-lingual, obtendo-se espécimes em forma de palitos, com secção transversal de aproximadamente 0.8 mm2. Os corpos-de-prova foram submetidos ao ensaio de microtração com velocidade de 0.5mm/min e célula de carga de 10kg. Os dados foram submetidos à análise estatística ANOVA e teste de Tukey (5%). Resultados: Os resultados (MPa) foram: D/SE: 24,06 ± 8,84, D/ONE: 15,03 ± 8,61, CVD/SE: 39,90 ± 8,24 e CVD/ONE:15,03 ± 8,61. Concluiu-se que o sistema adesivo Clearfil SE Bond apresentou superioridade significativa de resistência de união em relação ao preparo com ponta CVD; o método de preparo da dentina interferiu no desempenho do Clearfil SE Bond e não influenciou o desempenho do One-Up Bond F


Asunto(s)
Humanos , Dentina , Recubrimientos Dentinarios , Resistencia a la Tracción
11.
Braz. dent. sci ; 16(4): 84-92, 2013. tab, ilus
Artículo en Inglés | LILACS, BBO | ID: lil-728091

RESUMEN

Objective: This study evaluated the effect of root perforations on the bond strength of fiberglass posts cemented to the root canal with two adhesive systems and resin cement. Material and Methods: Forty single-rooted human teeth received endodontic treatment and were prepared for the cementation of fiberglass posts (Exacto Mini, Angelus). The teeth were divided into four experimental groups (n = 10) according to the root condition (with or without perforation) and the adhesive system used: G1: without perforation + Adper Single Bond 2 (3M ESPE), G2: without perforation + Clearfil SE Bond (Kuraray), G3: with perforation + Adper Single Bond 2, G4: with perforation + Clearfil SE Bond. The perforation was executed on the root surface with a diamond bur and sealed with white mineral trioxide aggregate (MTA). The specimens were sectioned and a push-out test was carried out (1 mm/min speed and 50 kgf). The data were statistically analyzed by ANOVA and Tukey Test (5%). Results: Adper Single Bond 2 promoted the greatest values of bond strength to the roots without root perforation. The presence of root perforation led to the reduction in bond strength values regardless of the bonding system used (p < 0.05). Conclusion: The root perforations caused a direct effect on the bond strength of the fiberglass posts cemented by reducing the bond strength values to the root dentin regardless of the adhesive system used.


Objetivo: O objetivo deste estudo foi avaliar o efeito das perfurações radiculares na resistência de união de pinos de fibra de vidro cimentados com dois sistemas adesivos e um cimento resinoso. Material e Métodos: Quarenta dentes humanos unirradiculares receberam tratamento endodôntico e foram preparados para cimentação de pinos de fibra de vidro (Exacto Mini, Angelus). Os dentes foram divididos em quatro grupos experimentais (n = 10) de acordo com a condição radicular (com ou sem perfuração) e o sistema adesivo utilizado: G1: sem perfuração + Adper™ Single Bond 2; G2: sem perfuração + Clearfil SE Bond; G3: com perfuração + Adper™ Single Bond 2; G4: com perfuração + Clearfil SE Bond. A perfuração foi realizada na superfície radicular com uma ponta diamantada e selada com agregado de trióxido mineral branco (MTA). Os espécimes foram seccionados para realização do teste de extrusão por cisalhamento (Push-out) com velocidade de 1 mm/ min e célula de carga de 50 Kgf. Os dados obtidos foram submetidos à Análise de Variância (ANOVA) e Teste de Tukey a 5%. Resultados: O sistema adesivo Adper Single Bond 2 promoveu os maiores valores de resistência de união nas raízes sem perfuração radicular. A presença de perfuração promoveu redução nos valores de resistência de união, independentemente do sistema adesivo utilizado (p < 0,05). Conclusão: As perfurações radiculares causaram efeito direto sobre a resistência de união dos pinos de fibra de vidro, promovendo redução nos valores da resistência de união independentemente do tipo de sistema adesivo utilizado.


Asunto(s)
Humanos , Cementación , Cementos Dentales , Recubrimientos Dentinarios
12.
Braz. dent. sci ; 16(3): 7-17, 2013. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: lil-707558

RESUMEN

Objetivo: O objetivo dessa pesquisa é apresentar aspectos controversos na condução da análise estatística inferencial quanto à seleção da unidade experimental e quanto ao procedimento adotado diante das falhas pré-teste. Método: Foram avaliadas 87 dissertações e teses na área da odontologia que realizaram ensaio de microtração disponíveis em três universidades públicas do estado de São Paulo: Faculdade de Odontologia da USP (São Paulo, Ribeirão Preto e Bauru), Faculdade de Odontologia da Unesp (Araraquara e São José dos Campos) e Faculdade de Odontologia da Unicamp (Piracicaba e Campinas). Resultados: Quanto à unidade experimental, 34 (39,08%) teses e/ou dissertações utilizaram o “palito” e 53 (60,91%) o “dente/bloco”. Quanto às falhas pré-teste, 9 (10,34%) teses e/ou dissertações atribuíram valor “0”, 6 (6,89%) desconsideraram os palitos, 2 (2,29%) atribuíram o valor mínimo de 2 MPa, 1 (1,14%) atribuiu o valor mínimo de 4 MPa, 1 (1,14%) atribuiu a metade do valor mínimo do grupo e 68 (78,16%) não citaram a ocorrência de falhas pré-testes. Conclusão: Quanto à unidade experimental, atualmente considera-se como unidade experimental o dente (ou o bloco cerâmico) e não o palito. Quanto à ocorrência de falhas pré-teste, considera-se: atribuição de um valor mínimo de resistência adesiva na condição experimental ou grupo considerado; expressar o número e percentual dos casos de falhas em cada condição experimental; qual tipo de falha foi incluído na análise estatística e informar exatamente como os autores procederam em relação ao delineamento experimental (unidade experimental e falhas pré-teste).


Objectives: The aim of this study was to present the controversial aspects in performing inferential statistical analysis with regard to selection of the experimental unit and procedures adopted in the case of pre-test failures. Methods: Eighty-seven dissertations and theses in the field of dentistry were evaluated, for which microtensile testing was made available at three public Universities in the State of São Paulo were performed, namely: School of Dentistry, USP; School of Dentistry, Unesp (Araraquara and São José dos Campos) and the Piracicaba School of Dentistry (Unicamp). Results: Regarding the experimental unit, 34 (39.08%) theses and/or dissertations used the “stick” and 53 (60.91%) the “tooth/block” type. With regard to pretest failures, 9 (10.34%) theses and/or dissertations attributed the value “0”, 6 (6.89%) disregarded the sticks, 2 (2.29%) attributed the minimum value of 2 MPa, 1 (1.14%) the minimum value of 4 MPa, 1 (1.14%) attributed half the minimum value of the group and 68 (78.16%) did not mention the occurrence of pretest failures. Conclusion: At present the experimental unit is considered to be the tooth (or ceramic block) and not the stick. As it relates to pre-test failures, the following are considered: attribution of a minimum bond strength value under experimental condition or in the group considered, an expressed number and percentage of cases of failures under each experimental condition; failures included in the statistical analysis and detailed explantion of how the authors performed with regard experimental designs (experimental unit and premature failures).


Asunto(s)
Interpretación Estadística de Datos , Diente
13.
Braz. dent. sci ; 16(3): 18-25, 2013.
Artículo en Inglés | LILACS, BBO | ID: lil-707559

RESUMEN

A hipersensibilidade dentinária pode ocorrer quando há exposição da dentina após preparos dentários para restaurações indiretas. Para evitar ou minimizar desconfortos pós-operatórios, os adesivos dentinários têm sido utilizados para proteger a dentina exposta. Esta técnica é denominada pré-hibridização. Apesar da utilização clínica, ainda existem controvérsias sobre a eficácia, o material e o protocolo mais adequado para realizá-la. Objetivo: Esta revisão tem como objetivo discutir os conceitos que envolvem a pré-hibridização, baseando-se nos artigos mais relevantes publicados (2002 até a data atual), indexados nas bases de dados da SciELO, MEDLINE e Pubmed. Método: Para a pesquisa foram utilizadas as seguintes palavras-chave: pré-hibridização, hipersensibilidade dental e variáveis (ex.: pré-hibridização dentinária, hipersensibilidade dentinária, tratamento de hipersensibilidade). Foram selecionadas as referências do tipo revisão e artigos de pesquisa originais. Foram feitos esforços para identificar estudos sobre tratamentos clínicos comparativos, controlados e estudos de meta-análise sobre a hipersensibilidade e a pré-hibridização dentinária. Resultado: Baseado na revisão realizada é possível destacar os adesivos autocondicionantes como a primeira escolha para os procedimentos de pré-hibridização. Conclusão: Porém, a literatura ainda não apresenta um protocolo consolidado e as pesquisas clínicas que estudam a eficiência desta técnica são limitadas.


Dentinal hypersensitivity may occur after the dentine exposure because of indirect restoration preparations. Either to avoid or decrease postoperative discomfort, dentinal adhesives have been used to protect the exposed dentine. This technique is called pre-hybridization. Notwithstanding, despite of the clinical use, there still exist controversies on its efficacy and the most adequate material and protocol to execute it. Objective:This review study aimed to discuss the concepts involving the pre-hybridization based on the most important papers published from 2002 to date, indexed at the following databases: SciELO, MEDLINE and Pubmed. Methods: The following keywords were applied in the searching: pre-hybridization, tooth hypersensitivity and their possibilities (e.g.: dentinal pre-hybridization, dentinal hypersensitivity, hypersensitivity treatment). Only review and original research studies were selected. Efforts to identify comparative, controlled clinical studies as well as meta-analysis studies on hypersensitivity and dentinal pre-hybridization were made. Results: Based on the review conducted, it was possible to highlight that the self-conditioning adhesives have been the first choice for pre-hybridization procedures. Conclusion: However, the literature still lacks on determining a consolidated protocol and the clinical effectiveness of this procedure.


Asunto(s)
Cementos Dentales , Recubrimientos Dentinarios
14.
UNOPAR Cient., Ciênc. biol. saude ; 14(4): 207-210, out. 2012. tab
Artículo en Portugués | LILACS-Express | LILACS | ID: lil-655264

RESUMEN

Um dos principais sinais clínicos de problemas disfuncionais na região estomatognática é a restrição dos movimentos excursivos. A avaliação desses movimentos é uma importante variável na avaliação do estado funcional do sistema mastigatório. Este estudo foi realizado em 20 pacientes do gênero feminino com faixa etária entre 20 e 50 anos da Faculdade de Odontologia da Universidade Federal de Juiz de Fora e teve como objetivo comparar a amplitude dos movimentos excursivos no pré e pós-tratamento dos pacientes com desordem temporomandibular (DTM), para avaliar nos pacientes se há correlação entre o aumento das amplitudes de movimentos excursivos com a redução da dor. Para isso, utilizou-se uma régua de graduação milimétrica com pontos previamente marcados, posicionada em sentido vertical para medir a amplitude do movimento de lateralidade e em sentido horizontal a fim de registrar a protrusão. Como resultado, houve um aumento das amplitudes dos movimentos excursivos aliado a uma redução dos sinais e sintomas de DTM em 95% dos casos. Observou-se diferença significante nas amplitudes dos movimentos de lateralidade quando foram analisados os períodos de pré e pós-tratamento, visto que o movimento protrusivo não apresentou relevante diferença. Conclui-se que o uso de Férula Neuromiorrelaxante como terapia foi eficiente para reduzir os sinais e sintomas de DTM.


One of the main clinical signs of dysfunctional problems in the stomatognathic region is the restriction of excursive movements. The evaluation of these movements is an important variable in assessing the functional status of the masticatory system. This study was performed in 20 female patients aged between 20 and 50 years of the Faculty of Dentistry, Federal University of Juiz de Fora and aimed to compare the extent of excursive movements in pre-and post-treatment of patients with temporomandibular disorder (DTM) to evaluate the correlation between the increase of the amplitudes of excursive movements with pain reduction in patients. For this, we used a ruler with millimeter graduation points previously marked and positioned vertically to measure the extent of lateral movement and horizontally to register the protrusion. As a result, there was an increase in the amplitude of excursive movement combined with a reduction of signs and symptoms of DTM in 95% of cases. There was significant difference in amplitudes of lateral movements when analyzing pre and post-treatment periods, whereas the protrusive movement showed no significant difference. It is concluded that the use of Ferula Neuromiorelaxante as therapy was effective in reducing the signs and symptoms of TMD.

15.
Artículo en Inglés | IMSEAR | ID: sea-145794

RESUMEN

Aim: Compare the effect of three post designs on the fracture resistance and failure modes of composite core - fiber post - crownless tooth sets. Materials and Methods: Ninety bovine incisors were selected and divided into nine groups of 10 specimens. The teeth were assigned to three groups based on the post design: Cylindrical, tapered, and double-tapered. Each group was subdivided into three subgroups in accordance with the diameter of the post: Small (No.1), medium (No.2), and large (No.3). The Panavia F system was used for post cementation. The specimens were mounted in acrylic resin blocks with a layer of silicone rubber covering the roots. A universal testing machine compressively loaded the specimens from the palatal side at a crosshead speed of 1 mm/min and at an angle of 135Ί to the long axis of the teeth, until failure occurred. The failure mode was determined by a stereomicroscope inspection of all the specimens. Data were analyzed by one-way ANOVA and the Tukey test (P < 0.05). Results: The fracture resistance was affected by the type of post (P < 0.0001). A narrower diameter for all of the post systems allowed for higher resistance. The main failure mode in the large cylindrical group was catastrophic fractures, while the main failures in the other eight groups were favorable. Conclusion: Narrower diameter posts showed higher fracture resistance. The dominant failure pattern was repairable fracture, except for those with large cylindrical groups.


Asunto(s)
Animales , Bovinos , Coronas , Análisis del Estrés Dental , Vidrio , Incisivo/fisiopatología , Ensayo de Materiales , Modelos Animales , Técnica de Perno Muñón/instrumentación , Técnica de Perno Muñón/métodos , Fracturas de los Dientes/fisiopatología
16.
J. appl. oral sci ; 20(4): 427-434, July-Aug. 2012. ilus, tab
Artículo en Inglés | LILACS | ID: lil-650619

RESUMEN

OBJECTIVES: The objective of the present study was to evaluate a prefabricated intraradicular threaded pure titanium post, designed and developed at the São José dos Campos School of Dentistry - UNESP, Brazil. This new post was designed to minimize stresses observed with prefabricated post systems and to improve cost-benefits. MATERIAL AND METHODS: Fracture resistance testing of the post/core/root complex, fracture analysis by microscopy and stress analysis by the finite element method were used for post evaluation. The following four prefabricated metal post systems were analyzed: group 1, experimental post; group 2, modification of the experimental post; group 3, Flexi Post, and group 4, Para Post. For the analysis of fracture resistance, 40 bovine teeth were randomly assigned to the four groups (n=10) and used for the fabrication of test specimens simulating the situation in the mouth. The test specimens were subjected to compressive strength testing until fracture in an EMIC universal testing machine. After fracture of the test specimens, their roots were sectioned and analyzed by microscopy. For the finite element method, specimens of the fracture resistance test were simulated by computer modeling to determine the stress distribution pattern in the post systems studied. RESULTS: The fracture test presented the following averages and standard deviation: G1 (45.63±8.77), G2 (49.98±7.08), G3 (43.84±5.52), G4 (47.61±7.23). Stress was homogenously distributed along the body of the intraradicular post in group 1, whereas high stress concentrations in certain regions were observed in the other groups. These stress concentrations in the body of the post induced the same stress concentration in root dentin. CONCLUSIONS: The experimental post (original and modified versions) presented similar fracture resistance and better results in the stress analysis when compared with the commercial post systems tested (08/2008-PA/CEP).


Asunto(s)
Animales , Bovinos , Análisis del Estrés Dental/métodos , Técnica de Perno Muñón , Titanio/química , Fracturas de los Dientes/fisiopatología , Análisis de Varianza , Fuerza Compresiva , Diseño de Prótesis Dental , Análisis de Elementos Finitos , Imagenología Tridimensional , Ensayo de Materiales , Distribución Aleatoria , Estrés Mecánico , Propiedades de Superficie , Resistencia a la Tracción
17.
Braz. dent. sci ; 15(1): 33-38, 2012. ilus, tab, graf
Artículo en Inglés | LILACS, BBO | ID: lil-728079

RESUMEN

The aim of this in vitro study was to evaluate the bonding efficiency between two self-adhesive cements to enamel and dentine, with and without previous dental surface conditioning, before and after thermocycling. Thirty-six molars were divided into 3 experimental groups and 01 control group. The self-adhesive resin cements selected for the experimental groups were: RelyX Unicem (subgroups RE and RD) and Bifix SE (subgroups BE and BD). For control groups, a conventional resin cement, Variolink II (subgroups VRE and VRD), was used. The specimens were submitted to microtensile bond strength test. The results were submitted to analysis of variance (ANOVA) and Tukey’s test. The results showed statistically significant differences between VR group and the others before and after thermocycling. According to the results obtained, it can be concluded that self-adhesive cements, despite of their practicality and less sensitive technique concerning to cementation, have lower adhesive resistance when compared to conventional resin cements


O objetivo deste trabalho foi analisar in vitro a eficiência de adesão através de ensaio de microtração, de dois cimentos autocondicionantes (self-adhesive), sobre esmalte e dentina, antes e após termociclagem em comparação a um cimento resinoso convencional. Foram utilizados 36 terceiros molares, separados em grupos experimentais, sendo 2 grupos com cimentos resinosos auto-condicionantes (Rely X Unicem - 3M ESPE – subgrupos RE e RD) e Bifix SE - Voco/GHB – subgrupos BE e BD) e 1 grupo controle, com o cimento adesivo (Variolink II – Ivoclair - subgrupo VRE e VRD). Para a análise estatística do teste de adesão, foi utilizado ANOVA 3 fatores com teste de comparação múltipla de Tukey (5%). Os resultados evidenciaram diferença significante entre os grupos VR, dos demais grupos, antes e após termociclagem. De acordo com os resultados, podemos concluir que os cimentos autocondicionantes, apesar da sua praticidade, facilidade de técnica e menor susceptibilidade de hidrólise, ainda possuem menor resistência adesiva em relação aos cimentos resinosos convencionais.


Asunto(s)
Humanos , Cementación , Cementos Dentales
18.
RPG rev. pos-grad ; 18(3): 154-159, jul.-set. 2011. ilus, tab
Artículo en Portugués | LILACS | ID: lil-680247

RESUMEN

O objetivo deste trabalho foi avaliar as discrepâncias de assentamento de copings metálicos fundidos e sinterizados. Para tanto, foram comparados dois grupos de oito copings metálicos; um deles obtido pela técnica de fundição (NiCr) e outro pela técnica da sinterização (Ti-6Al-7Nb). Em ambos foi avaliada a adaptação dos mesmos sobre um troquel metálico com as características e medidas proporcionais a um preparo para coroa total em molar. A leitura da adaptação foi feita em oito pontos equidistantes do perímetro de cada coping por meio de um cabeçote micrométrico digital acoplado a um microscópio óptico de medição (Mitutoyo Mfg. Co., Tó-quio, Japão). Os dados obtidos foram submetidos ao teste t de Student, no qual verificou-se que a comparação entre as médias não apresentou diferenças estatisticamente significantes (t = 0,44; gL = 14; p = 0,668) ao nível de 5%. Os valores médios foram próximos e de mesma variabilidade (coeficiente de variação = 34,41 e 34,50%). Pôde-se concluir que os procedimentos de fundição ou sinterização não influenciaram na justeza de adaptação marginal dos copings metálicos e os copings de titânio, obtidos pela sinterização, podem ser uma alternativa satisfatória para a restauração de elementos protéticos.


Asunto(s)
Técnica de Colado Dental , Adaptación Marginal Dental , Operatoria Dental , Prostodoncia
19.
RFO UPF ; 16(1)jan.-abr. 2011.
Artículo en Portugués | LILACS | ID: lil-593682

RESUMEN

The objective was to evaluate the superficial roughness of a composite resin submitted to different surface treatments, in vitro. Thirty specimens were made with P60TM packable composite resin (3M ESPE), 6 mm thick and 3 mm in diameter. The samples were stored in distilled water for 7 days at 37 ºC and randomly assigned to two test groups. The baseline superficial roughness was determined with a profilometer. Fifteen specimens of each material were subjected to the following finishing and polishing procedures: Group I: multi-fluted burs/aluminum oxide disks (Diamond ProTM, FGM); Group II: multi-fluted burs/rubber tips (Enhance/PogoTM, Dent-sply). Time was limited to 20s per instrument. Following these procedures, it was accomplished a new reading and storage. Then the samples were polished with felt disks with diamond paste (Diamond ExcelTM, FGM), for 20s, and a surface sealant was applied (Biscover, BIS-CO). After all these procedures, the final roughness was determined. Statistical analysis was performed with RM ANOVA and Tukey´s tests (5%). Significant effects were found with both the polishing systems and the sealant (presence or absence). The polishing with Diamond Pro caused the greatest roughness on all composites (p < 0.05). After the application of Biscover the composite surfaces were smoother. This difference was significant for the group polished with Diamond Pro and not sig-nificant for the group polished with EnhanceTM/Pogo. It was concluded that the application of a surface sealant following polishing with aluminum oxide disks or abrasive rubbers results in a surface with smoothness superior to that obtained with these polishing devices alone.

20.
RPG, Rev. Pós-Grad ; 16(4): 201-206, out.-dez. 2009. tab, ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-855249

RESUMEN

O objetivo do estudo foi avaliar a resistência à tração de pino de fibra de vidro cimentado com três diferentes cimentos. Trinta dentes bovinos foram selecionados. Os comprimentos dos espécimes foram padronizados em 16 mm. Os espécimes foram divididos em três grupos, de acordo com os cimentos, os quais foram utilizados seguindo as instruções dos fabricantes: G1, Panavia F; G2, Ketac Cem; G3, RelyX Unicem. Os espécimes foram submetidos ao teste de tração em uma máquina de teste universal com velocidade de 1 mm/min. Os dados obtidos foram submetidos aos testes ANOVA e Tukey (µ = 0,05). O G2 (37,25 ± 10,84 Kgf) demonstrou maior resistência ao teste de tração (p < 0,0034) quando comparado ao G3 (24,24 ± 6,47 Kgf) e G1 (23,45 ± 9,78 Kgf) os quais não diferiram estatisticamente entre si. A análise dos espécimes demonstrou que todas as falhas do G1 e G3 ocorreram na interface cimento/dentina radicular, enquanto todas as falhas do G2 ocorreram na interface pino/cimento. Concluiu-se que o cimento de ionômero de vidro Ketac Cem produziu maior resistência à tração dos pinos de fibra de vidro, quando comparado aos cimentos resinosos RelyX Unicem e Panavia F. A hipótese nula foi aceita (p < 0,0034)


Asunto(s)
Bovinos , Cementos Dentales , Pins Dentales , Cementos de Resina , Resistencia a la Tracción , Cavidad Pulpar , Dentina , Cementos de Ionómero Vítreo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA