Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Rev. Ciênc. Saúde ; 13(4): 4-10, Dezembro 2023.
Artículo en Inglés | LILACS | ID: biblio-1525676

RESUMEN

Objectives: To investigate the effect of exercise intensity on functional capacity in individuals with coronary artery disease, assess adherence to the heart rate training zone (HRTZ), and relationship between trained intensity and functional capacity. Methods: Retrospective study led with medical records of 54 outpatients with coronary artery disease in a public hospital. The prescribed intensity started at 50 ­60% of heart rate reserve, increasing monthly to 70 ­80% by the third month. Spearman's test was used to assess the correlation between improvement in distance in the incremental shuttle walk test (ISWT), exercise intensity, and rating of perceived exertion (Borg­RPE). Adherence was classified as 'below' when HRTZ was not achieved in any phase of the program, 'intermediate' when HR was within the HRTZ for one or two months, and 'above' when HR was at or higher than HRTZ two months. Improvement was tested with t-test and one-way ANOVA. Results: 51.9% of participants had an increase in ISWT of ≥70 m (p < 0.0001). In at least one month, 50.9% trained below HRTZ. Trained intensity did not go below 8.6% of the prescribed minimal threshold of HRTZ. Changes in ISWT were not significantly correlated with exercise intensity (p = 0.87) or Borg­RPE (p = 0.16). Conclusion: While a significant increase in functional capacity was found, considerable heterogeneity in changes were observed. This may, in part, be related to adherence to HRTZ with progressive exercise intensity and to the variability in exercise volume incardiovascular rehabilitation programs.


Asunto(s)
Humanos , Registros Médicos , Prueba de Paso , Rehabilitación Cardiaca , Hospitales Públicos
2.
Int. j. cardiovasc. sci. (Impr.) ; 35(3): 329-339, May-June 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1375636

RESUMEN

Abstract Background: Right ventricular dysfunction is a major complication in chronic obstructive pulmonary disease (COPD) and, despite its prognostic implications, is rarely considered in routine clinical analysis. Objectives: To compare RV function variables with standard and advanced echocardiographic techniques in patients with stable COPD and controls. Methods: Twenty COPD patients classified as GOLD ≥ II (13 men aged 68.4 ± 8.3 years) and 20 matched controls were compared. Myocardial strain/strain rate indices were obtained by tissue Doppler and two-dimensional speckle tracking echocardiography. Right ventricular ejection fraction was obtained with three-dimensional software. Free wall myocardial thickness (FWMT) and tricuspid annular systolic excursion (TAPSE) were also measured. Numerical variables were compared between groups with Student's t-test or the Mann-Whitney test. Associations between categorical variables were determined with Fisher's exact test. P-values < 0.05 were considered statistically significant. Results: All myocardial deformation indices, particularly global longitudinal strain (-17.2 ± 4.4 vs -21.2: ± 4.4 = 0.001) and 3D right ventricular ejection fraction (40.8 ± 9.3% vs 51.1 ± 6.4% p <0.001) were reduced in COPD patients. These patients presented higher right ventricular FWMT and lower TAPSE values than controls. Conclusion: Myocardial deformation indices, either tissue Doppler or speckle tracking echocardiography and 3D right ventricular ejection fraction, are robust markers of right ventricular dysfunction in patients with stable COPD. Assessing global longitudinal strain by speckle tracking echocardiography is a more practical and reproducible method.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Disfunción Ventricular Derecha/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Estudios de Casos y Controles , Estudios Transversales , Disfunción Ventricular Derecha/etiología , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Enfermedad Pulmonar Obstructiva Crónica/terapia , Miocardio
3.
Int. braz. j. urol ; 39(4): 558-564, Jul-Aug/2013. tab, graf
Artículo en Inglés | LILACS | ID: lil-687304

RESUMEN

Introduction and Objective Circumcision is one of the oldest surgical procedures and one of the most frequently performed worldwide. It can be done by many different techniques. This prospective series presents the results of Plastibell® circumcision in children older than 2 years of age, evaluating surgical duration, immediate and late complications, time for plastic device separation and factors associated with it. Materials and Methods We prospectively analyzed 119 children submitted to Plastic Device Circumcision with Plastibell® by only one surgeon from December 2009 to June 2011. In all cases the surgery was done under general anesthesia associated with dorsal penile nerve block. Before surgery length of the penis and latero-lateral diameter of the glans were measured. Surgical duration, time of Plastibell® separation and use of analgesic medication in the post-operative period were evaluated. Patients were followed on days 15, 45, 90 and 120 after surgery. Results Age at surgery varied from 2 to 12.5 (5.9 ± 2.9) years old. Mean surgical time was 3.7 ± 2.0 minutes (1.9 to 9 minutes). Time for plastic device separation ranged from 6 to 26 days (mean: 16 ± 4.2 days), being 14.8 days for children younger than 5 years of age and 17.4 days for those older than 5 years of age (p < 0.0001). The diameter of the Plastibell® does not interfered in separations time (p = 0,484). Late complications occurred in 32 (26.8%) subjects, being the great majority of low clinical significance, especially prepucial adherences, edema of the mucosa and discrete hypertrophy of the scar, all resolving with clinical treatment. One patient still using diaper had meatus stenosis and in one case the Plastibell® device stayed between the glans and the prepuce and needed to be removed manually. conclusions Circumcision using a plastic device is a safe, ...


Asunto(s)
Niño , Preescolar , Humanos , Masculino , Circuncisión Masculina/instrumentación , Pene/cirugía , Factores de Edad , Circuncisión Masculina/métodos , Diseño de Equipo/efectos adversos , Tempo Operativo , Tamaño de los Órganos , Complicaciones Posoperatorias , Estudios Prospectivos , Pene/anatomía & histología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA