Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Braz. oral res. (Online) ; 38: e010, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1557356

RESUMEN

Abstract: This study evaluated the stress distribution in the dentoalveolar and palatal bone structures during maxillary expansion in a 17-year-old male patient with bilateral cleft lip and palate (BCLP) using expanders with dental (HYRAX) and skeletal anchorage (MARPE). For the generation of the specific finite element models, cone-beam computed tomography was used, and the DICOM files were exported to Mimics 3-Matic (Materialise) and Patran (MSC Software) software. Three specific three-dimensional models were generated: A) HYRAX: conventional four-banded hyrax screw (9 mm); B) MARPE-DS: 3 miniscrews (1.8 mm diameter - 5.4 mm length) and four-banded dental anchorage; and C) MARPE-NoDS: 3 miniscrews without dental anchorage. Maxillary expansion was simulated by activating the expanders transversely 1 mm on the "X" axis. HYRAX resulted in higher levels of deformation predominantly in the dentoalveolar region. MARPE-DS showed stress in the dentoalveolar region and mainly in the center of the palatal region, at approximately 4,000 με. MARPE-NoDS exhibited evident stress only in the palatal region. High stress levels in the root anchoring teeth were observed for HYRAX and MARPE-DS. In contrast, MARPE-NoDS cause stress on the tooth structure. The stress distribution from the expanders used in the BLCP showed asymmetric expansive behavior. During the initial activation phase of expansion, the HYRAX and MARPE-DS models produced similarly high strain at the dentoalveolar structures and upper posterior teeth displacement. The MARPE-NoDS model showed restricted strain on the palate.

2.
Rev. dental press periodontia implantol ; 5(3): 101-110, jul.-set.2011. ilus, tab, graf
Artículo en Portugués | LILACS, BBO | ID: lil-616335

RESUMEN

O objetivo deste estudo foi avaliar o impacto da reabilitação bucal com próteses fixas suportadas por implantes em pacientes edêntulos totais mandibulares. A amostra foi formada por doze pacientes do Instituto Nacional de Experimentos e Pesquisas Odontológicas (INEPO, São Paulo, Brasil), com média de idade de 59 anos, que se submeteram a cirurgia para instalação de quatro implantes na região mandibular seguida pela instalação de prótese fixa em protocolo de carga imediata funcional. Os pacientes responderam a um questionário contendo quatorze perguntas objetivas de múltipla escolha (OHIP-14 - Oral Health Impact Profile) em duas ocasiões: previamente à cirurgia de implantes e seis meses após a instalação da reabilitação protética. A análise estatística dos dados obtidos demonstrou que a qualidade de vida dos pacientes melhorou significativamente (P = 0,001) após a substituição da prótese total removível pela prótese fixa sobre implantes.


The aim of this study was to evaluate the impact of oral rehabilitation with fixed implant prosthesis in the quality of life of edentulous patients, The sample consisted of twelve patients from the National Institute of Dental Research and Experiments (INEPO, São Paulo, Brazil) with a mean age of 59 years who underwent surgery to install four implants in the lower jaw followed by fixed prosthesis with immediate functional loading. The patients answered a questionnaire containing fourteen multiple choice objective questions (OHIP-14 - Oral Health Impact Profile) on two occasions: first before the implant surgery, and then six months after the treatment with implant supported fixed prosthesis. Statistical analysis of data obtained demonstrated that the patients' quality of life improved significantly (P = 0,001) after the replacement of removable dentures by implant-supported fixed prosthesis.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Prótesis Dental de Soporte Implantado , Carga Inmediata del Implante Dental , Rehabilitación Bucal , Calidad de Vida , Arcada Edéntula , Mandíbula/cirugía , Satisfacción del Paciente , Interpretación Estadística de Datos
3.
Artículo en Portugués | LILACS, BBO | ID: lil-618561

RESUMEN

O uso de implantes osseointegráveis no tratamento do edentulismo é hoje uma das técnicas mais previsíveis e bem sucedidas no âmbito da odontologia contemporânea. Entretanto o protocolo mais utilizado para utilização destes implantes requer um período de osseointegração de alguns meses antes que a restauração protética seja efetivamente instalada. Muitas vezes, até mesmo de maneira empírica, para se diminuir este tempo de espera o protocolo original é alterado, diminuindo-se o período de osseointegração. O objetivo deste trabalho é apresentar de maneira sucinta o estágio atual de aprimoramento dos implantes dentários para aperfeiçoar o processo de osseointegração, com relação às alterações de superfície e da forma destes dispositivos, além de apresentar os resultados clínicos obtidos com a instalação de 603 implantes com tratamento de superfície por duplo ataque ácido e câmara de cicatrização.


The use of osseointegrated implants in the handling of the edentulism is today one of the most foreseeable techniques and well happened in the scope of the contemporary dentistry. However the more utilized protocol for utilization of these implants requires a period of osseointegration of some months before the prosthetic restoration can be actually installed. Many times, to even of empirical way, for diminish this time of wait the original protocol is bad-tempered, diminishing the period of osseointegração. The objective of this work is going to present in a succinct way, the present stage of improvement the dental implants to optimize the trial of osseointegration, regarding the alterations of surface and of the form of these devices and to present the clinical results of 603 dual acid etched dental implants with healing chambers.


Asunto(s)
Implantes Dentales , Oseointegración , Cicatrización de Heridas
4.
Artículo en Portugués | LILACS, BBO | ID: lil-618564

RESUMEN

O objetivo deste trabalho é avaliar a influencia do platform- switching nas deformações do osso peri-implantar e nas tensões do parafuso passante de implantes em áreas estéticas. Modelos em elementos finitos de um alvéolo de extração de um incisivo central superior, de um implante com 13 mm de comprimento por 4,5 de plataforma e de abutments com 4,5, 4,0 e 3,5 mm foram construídos. Os abutments de 4,0 e 3,5 mm acarretaram uma desadaptação horizontal de 0,5 e 1,0 mm (platform-switching), respectivamente. Um carregamento de 100 N foi aplicado sobre os abutments. Uma melhor distribuição de deformações no osso marginal peri-implantar são encontradas nos designes em platform-switching. Por outro lado, uma maior concentração de tensões no parafuso da prótese deve ser esperada para esta configuração.


The purpose of this study is to evaluate the influence of platform-switching configuration on the strain in periimplant bone and on the stress in the abutment screw. CT-based finite element models comprising an upper central incisor socket, a 13-mm implant with 4,5 mm of shoulder diameter and abutments of 4.5, 4.0 and 3.5 mm diameter were constructed. The abutments de 4.0 and 3.5 mm diameter represent the horizontal mismatch of 0.5 and 1.0 mm (platform-switching), respectively. 100 N magnitude load was applied over the abutments. A better strain distribution in periimplant marginal bone was encountered in platform- switching designs. On the other hand, a higher stress concentration could be found in the abutment screw.


Asunto(s)
Fenómenos Biomecánicos , Implantes Dentales , Oseointegración
5.
Artículo en Portugués | LILACS, BBO | ID: lil-561130

RESUMEN

O objetivo deste trabalho foi avaliar a influência do desenho do implante nas micromovimentações de implantes imediatos com carga imediata. Modelos em elementos finitos de um alvéolo de extração de um incisivo central superior e quatro desenhos de implantes de conexão interna, disponíveis comercialmente (SIN SW®, 3i Certain®, Nobel ReplaceTM e RN synOcta® ITI Standard), com diâmetros e comprimentos semelhantes foram construídos. Cargas de 50, 100 e 200 N foram aplicadas sobre os implantes. ANOVA com nível de 95% de significância foi utilizada para avaliar os dados da micromovimentação dos implantes. O design do implante influencia significativamente (31,21%) a micromovimentação de implantes imediatos com carga imediata. Não obstante, a intensidade da carga aplicada (68,80%) é o fator mais importante na estabilidade dos implantes neste protocolo.


The purpose of this paper was to evaluate the influence of different implant designs on the micromovements of immediately placed implants. CT-based finite element models comprising an upper central incisor socket and four commercially available internal connection implant designs (SIN SW®, 3i Certain®, Nobel ReplaceTM, and RN synOcta® ITI Standard) of comparable diameter and length were constructed. 50, 100 and 200N magnitude loads were applied over the implant. ANOVA at 95% level of significance was used to evaluate bone to implant relative displacement (micromovements). The implant design (68,80%) greatly influences the micromovement of immediately placed implants. However, the loading magnitude (68,80%) is the most important factor regarding the implant stability in this protocol.


Asunto(s)
Fenómenos Biomecánicos , Implantes Dentales , Oseointegración
6.
Innov. implant. j., biomater. esthet. (Impr.) ; 4(2): 10-16, maio-ago. 2009. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-561079

RESUMEN

Objetivo: o objetivo do presente estudo foi analisar o ambiente biomecânico de implantes imediatos com carga imediata, comparando 3 diferentes magnitudes de carga. Material e Métodos: um modelo em elementos finitos de um incisivo central superior contendo um implante cônico de 13 mm de comprimento e 4,5 mm de plataforma, hexágono interno, foi construído. Elementos de contato friccional foram utilizados para simular as interfaces entre o osso, implante, abutment e parafuso do abutment. Foram aplicadas forças de 50, 100 e 200 N na extremidade superior do abutment. Os dados para a deformação equivalente no osso, as tensões equivalentes no parafuso, deslocamento relativo osso-implante e gap do abutment foram calculados. Resultados/Conclusão: a magnitude das cargas aplicadas sobre os implantes imediatos com carga imediata influenciam significativamente o ambiente biomecânico deste protocolo.


Objective: the purpose of the present study was to evaluate the biomechanical environment of immediately placed implants, by comparing three different loading magnitudes. Material and Methods: a CT-based finite element model of an upper central incisor extraction socket was constructed containing a conical internal hex 13-mm implant. Frictional contact elements were used in the bone, implant, abutment and abutment screw interfaces. Forces of 50, 100 and 200 N were applied on the superior central region of the abutment. Data for the peak equivalent strain in the bone, peak Von Mises stress in the abutment screw, bone-to-implant relative displacement and abutment gap were calculated. Results/Conclusion: the loading magnitudes applied over the implants are capable to greatly influence the biomechanical environment in immediately placed protocol.


Asunto(s)
Fenómenos Biomecánicos , Implantes Dentales , Oseointegración
7.
Artículo en Portugués | LILACS, BBO | ID: lil-561052

RESUMEN

A previsibilidade e o sucesso longitudinal do tratamento por implantes são altamente influenciados pelo ambiente biomecânico ao qual o implante é exposto. A concentração de tensão e deformação pode induzir reabsorção óssea e falhas como desaperto e fratura de parafusos. Neste sentido, o Método de Elementos Finitos tem sido utilizado como ferramenta para avaliação das tensões, deformações e deslocamentos gerados pelas cargas mastigatórias sobre os implantes osseointegráveis, com a finalidade de solucionar problemas estruturais complexos e prognosticar possíveis condições de falha. A expansão da utilização destes métodos é fundamentada em vantagens como custo relativamente baixo, versatilidade e a ausência de mutilações em animais ou humanos, além da confiabilidade comprovada pela larga utilização em diversas áreas do conhecimento. Este artigo tem por objetivo discutir a aplicabilidade do MEF na análise dos aspectos biomecânicos relacionados aos implantes dentais osseointegráveis. Este método foi detalhado didaticamente no que se refere á sua execução e à leitura dos resultados. Foram citados 44 estudos, selecionados no MedlineTM, tendo como critérios de inclusão a relevância do tema, a boa qualidade da metodologia e a importância do periódico onde estão publicados. As palavras-chave utilizadas foram: dental implants, immediate load, finite element, biomechanic e bone loss, em variadas combinações.


The previsibilty and the longitudinal sucess in the treatment with dental implants are highly influenced by the biomechanical conditions of the area where the implant will be installed. The load stress concentration and implant deformation, could facilitate the induction of perimplantar bone resorption as well as some failures and screw fracture. The finite elements method has been used as a tool for this kind of studies, to evaluate tensions, deformations and dislocations caused by masticatory forces on the osseointegrated implants. The finite elements method utilization has expanded in those research works considering its low cost, versatility and the absence of animals or patients, since it is mathematically done as a simulation in the computer. This method of study has acquired credibility in the literature and has been used in many different areas of acknowledgements. The purpose of finite elements method in the present research work is to discuss its applicability in relation to osseointegrated dental implants. It provides detailed results and its execution is not difficult. In the review of the literature 44 studies have been selected and presented considering the subject relevance, emphasizing the method quality and the important periodicals where the studies were published.


Asunto(s)
Análisis de Elementos Finitos , Fenómenos Biomecánicos/métodos , Implantes Dentales , Implantes Dentales/efectos adversos , Implantes Dentales
8.
Periodontia ; 16(2): 65-70, jun. 2006. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-510817

RESUMEN

Foram utilizados para o presente estudo sete intermediários de titânio para cada grupo de marca comercial, analisados pela técnica de interferometria a laser, a qual é executada através de um perfilômetro a laser, marca UBM, modelo MICROFOCUS EXPERT IV. As leituras realizadas foram subdivididas em áreas planas e inclinadas, de acordo com a anatomia do componente. Os dados obtidos foram processados pelo software DIGITAL SURF MOUNTAIS MAP UNIVERSAL® - Versão 3.1.9, o qual gerou imagens tridimensionais para uma aná-lise qualitativa da topografia superficial. Além disso, foram considerados pelo presente estudo o total de quatro parâmetros de rugosidade para a análise quantitativa. De acordo com os resultados, observouse que os intermediários de titânio analisados não demonstraram uniformidade nas suas características topográficas superficiais quando comparadas as áreas inclinadas e planas de um mesmo componente, independente da marca comercial. Além disso, nenhum dos grupos obteve médias de rugosidade média (Sa) iguais ou inferiores aquelas presentes na literatura científica.


Asunto(s)
Prótesis e Implantes , Interpretación de Imagen Asistida por Computador , Interferometría , Titanio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA