Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Inglés | IMSEAR | ID: sea-38699

RESUMEN

The pharmacokinetic and relative bioavailability studies of 20-mg enalapril tablets, the test product manufactured by Biolab, Thailand compared to the reference product (Merck Sharp & Dohme, USA) was conducted in 14 healthy Thai male volunteers following a single dose, two-period, crossover design. Each subject received 20-mg enalapril tablets of both formulations with a 1-week washout period. Plasma samples collected over a 24-h period after administration were analyzed by LC/MS/MS. Pharmacokinetic parameters were determined by using non-compartmental analysis. Regarding bioequivalence testing, the 90 per cent confidence intervals of Cmax and AUC(0-infinity) ratios (test/reference) of enalapril were 101.8-134.9 per cent and 105.9-121.4 per cent and those of enalaprilat were 104.2-122.3 per cent and 104.5-118.1 per cent. Based on the European bioequivalence guideline, the 90 per cent confidence intervals of Cmax and AUC(0-infinity) ratios of both parent and metabolite forms were within the acceptable ranges of 70-143 per cent and 80-125 per cent, respectively. It was concluded that the test formulation was bioequivalent to the reference formulation and both formulations can be used interchangeably in clinical practice.


Asunto(s)
Adolescente , Adulto , Antihipertensivos/farmacocinética , Disponibilidad Biológica , Estudios Cruzados , Enalapril/farmacocinética , Enalaprilato/farmacocinética , Humanos , Masculino , Persona de Mediana Edad , Voluntarios
2.
Artículo en Inglés | IMSEAR | ID: sea-45288

RESUMEN

OBJECTIVES: To assess the average bioequivalence of two formulations of 8-mg ondansetron tablets--test product (Unison Laboratories, Thailand) and reference product (Glaxo Wellcome, USA)--in 14 healthy Thai male volunteers. MATERIAL AND METHOD: In a randomized, single dose, fasting, two-period, crossover study design with a 1-week washout period, each subject received an 8-mg ondansetron tablet. Serum samples were collected over a 24-hour period after administration. Subsequently serum concentrations of ondansetron were analyzed by using a validated HPLC-UV method. Pharmacokinetic parameters were determined by using non-compartmental analysis. RESULTS: No significant difference was observed in any of the pharmacokinetic parameters analyzed. The time to reach the maximal concentration (Tmax, hour), the peak concentration (Cmax, ng/ ml) and the area under the concentration-time curve (AUC(0-infinity), ng x h/ml) of ondansetron for reference and test preparations were 2.6 + 1.8 vs 2.2 + 0.6, 49.5 +/- 18.9 vs 48.5 +/- 13.7 and 352.2 +/- 184.7 vs 323.8 +/- 154.5, respectively. The 90 per cent confidence intervals for Test/Reference ratio of Cmax and AUC(0-infinity) were found within the bioequivalence range of 80-125 per cent (90.3-110.0% and 88.4-99.6%, respectively). CONCLUSION: The bioequivalence of these two ondansetron preparations was demonstrated.


Asunto(s)
Administración Oral , Adolescente , Adulto , Antieméticos/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Ondansetrón/administración & dosificación , Valores de Referencia , Comprimidos , Tailandia , Equivalencia Terapéutica
3.
Artículo en Inglés | IMSEAR | ID: sea-41737

RESUMEN

The bioequivalence study of 5-mg enalapril tablets, Enaril (Biolab, Thailand) compared to Renitec (Merck Sharp & Dohme, USA) was conducted in 14 healthy Thai male volunteers following a single dose, two-period, crossover design. Each subject received 4 tablets of 5-mg enalapril tablets of both formulations with a 1-week washout period. Plasma samples collected over a 24-hour period after administration were analyzed by LC/MS/MS. Pharmacokinetic parameters were determined by using non-compartmental analysis. Regarding bioequivalence testing, the 90 per cent confidence intervals of Cmax and AUC(0-infinity) ratios (Enaril/Renitec) of enalapril were 86.3-126.1 per cent and 93.0-118.5 per cent and those of enalaprilat were 86.4-124.1 per cent and 90.3-116.8 per cent. Based on the European bioequivalence guideline, the 90 per cent confidence interval of Cmax and AUC(0-infinity) ratios of both parent and metabolite forms were within acceptable ranges of 70-143 per cent and 80-125 per cent, respectively. It was concluded that Enaril 5 mg tablet was bioequivalent to Renitec 5 mg tablet.


Asunto(s)
Adolescente , Adulto , Inhibidores de la Enzima Convertidora de Angiotensina/administración & dosificación , Intervalos de Confianza , Estudios Cruzados , Enalapril/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Tailandia , Equivalencia Terapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA