Journal of Southern Medical University ; (12): 1063-1065, 2010.
Artículo en Chino | WPRIM | ID: wpr-289993

RESUMEN

<p><b>OBJECTIVE</b>To evaluate neointimal proliferation following placement of a new drug-eluting stent (BUMA) by optical coherence tomography (OCT).</p><p><b>METHODS</b>Twenty-two patients with coronary artery disease were randomized into BUMA group (n=15) and Endeavor group (n=7) and underwent OCT imaging after 9 months of stent implantation.</p><p><b>RESULTS</b>The neointima hyperplasia (NIH) thickness in BUMA group were significantly smaller than that in endeavor group (0.220-/+0.140 mm vs 0.269-/+0.207 mm, P<0.001), and the uncovered Struts were significantly lower in BUMA group than in Endeavor group (5.65% vs 6.56%, P<0.0001). The luminal late loss in BUMA group was also significantly lower (34.87-/+11.50 vs 40.82-/+18.53, P=0.025).</p><p><b>CONCLUSION</b>BUMA stent is safe and effective for treatment of coronary artery disease.</p>


Asunto(s)
Humanos , Angioplastia Coronaria con Balón , Proliferación Celular , Enfermedad de la Arteria Coronaria , Patología , Terapéutica , Vasos Coronarios , Patología , Stents Liberadores de Fármacos , Estudios Prospectivos , Tomografía de Coherencia Óptica , Túnica Íntima , Patología
2.
Chinese Journal of Cardiology ; (12): 585-589, 2009.
Artículo en Chino | WPRIM | ID: wpr-236450

RESUMEN

<p><b>OBJECTIVE</b>To evaluate the characteristic of late stent malposition after drug-eluting stent implantation by optical coherence tomography (OCT).</p><p><b>METHODS</b>The study comprised of 32 patients (target vessels: 51, total stents: 71) underwent drug eluting stent implantation one year ago [average (14.8 +/- 5.2) months]. OCT images of the stent were analyzed at interval of 0.5 mm. The stent malposition was detected, the thickness of intima and gap between the stent strut and vessel wall were measured.</p><p><b>RESULTS</b>Stent malposition was detected in 7 patients without clinical cardiac events, including positive remodeling (n = 4), overlapping stents (n = 1) and stent struts covered with thrombus (n = 2). Stent strut apposition with complete intima coverage was about 97.6%, stent struts malposition was 2.4% including half of struts located at the ostium of side branch. The intima coverage of stent struts is similar between the struts at the side branch and others [(0.06 +/- 0.05) mm vs. (0.05 +/- 0.03) mm, P > 0.05].</p><p><b>CONCLUSION</b>The causes of late stent malposition include the primary malposition after stent implantation, positive remodeling, overlapping stents and stent struts located at the ostium of side branch. Thinner intima coverage was also observed on the stent struts with malposition.</p>


Asunto(s)
Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Stents Liberadores de Fármacos , Tomografía de Coherencia Óptica , Insuficiencia del Tratamiento