Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Artículo en Chino | WPRIM | ID: wpr-1022065

RESUMEN

OBJECTIVE:Cold water immersion methods are not standardized in terms of operational indicators such as immersion temperature,duration and depth,leading to controversy over the efficacy of recovery from exercise fatigue in skeletal muscle.In this article,we analyze the effects of cold water immersion on muscle injury,muscle soreness and muscle strength recovery under different factors,in order to find the best immersion implementation plan,and thus provide evidence for the recovery of muscle fatigue. METHODS:A search of CNKI,WanFang Data,Web of Science,and PubMed databases was conducted for relevant literature published from January 1,2000 to August 15,2023.A total of 4 759 articles were initially retrieved,with 4 735 articles excluded through screening and 24 articles finally included.The Physical Therapy Evidence Database Scale was used to assess the methodological quality of the included literature,and Stata-MP 16 software was used to perform effect size combinations,subgroup analyses,Meta-regression,sensitivity tests,and publication bias analyses. RESULTS:(1)The article included a total of 24 randomized controlled trial studies,including 617 subjects,with overall high legal quality.(2)Meta-analysis showed that cold water immersion can significantly reduce creatine kinase blood value[standardized mean difference(SMD)=-0.17,95%confidence interval(CI):-0.29 to-0.05,P<0.01],alleviate muscle pain(SMD=-0.60,95%CI:-0.81 to-0.38,P<0.01),and promote maximum muscle strength recovery(SMD=0.17,95%CI:0.05 to 0.30,P<0.01).(3)Subgroup analysis showed that:The immersing regimen with water temperature>14 ℃(SMD=-0.48,95%CI:-0.76 to-0.20,P<0.01)and duration of 12-14 minutes(SMD=-0.38,95%CI:-0.61 to-0.15,P<0.01)had the best effect in reducing creatine kinase blood values,and had a more significant intervention effect on endurance exercise(SMD=-0.45,95%CI:-0.71 to-0.20,P<0.01),while the immersion regimen with water temperature<10 ℃(SMD=-0.61,95%CI:-0.79 to-0.43,P<0.01),duration<12 minutes(SMD=-0.76,95%CI:-0.98 to-0.53,P<0.01),and immersion depth above the iliac spine(SMD=-0.74,95%CI:-0.97 to-0.52,P<0.01)had the best effect on relieving muscle soreness,and had a more significant analgesic effect after endurance exercise(SMD=-0.42,95%CI:-0.61 to-0.22,P<0.01).(4)Meta regression showed that immersion water temperature,immersion duration,and exercise type were important regulatory factors affecting the effect size of creatine kinase;immersing water temperature and immersing depth were important regulatory factors affecting the effect size of visual analogue scale score,while exercise type was an important regulatory factor affecting the maximum isometric muscle strength effect size. CONCLUSION:(1)Evidence of extremely low to moderate strength suggests that cold water immersion can effectively reduce muscle damage,alleviate muscle soreness,and promote muscle strength recovery.(2)In terms of reducing muscle injury,immersion water temperature,immersion duration,and exercise type are significant regulatory factors that affect the efficacy of immersing.Among them,immersion water temperature>14 ℃ and duration of 12-14 minutes are the best solutions to reduce muscle injury after exercise,and the immersing effect is better for endurance exercise.(3)In terms of reducing muscle soreness,immersion water temperature and immersion depth are important regulatory factors that affect the intervention effect.Among them,immersion water temperature<10 ℃,duration<12 minutes,and immersing depth above the iliac spine are the best solutions to reduce muscle soreness,and have a better analgesic effect after endurance exercise.(4)In terms of promoting muscle strength recovery,exercise type is a key regulatory factor that affects the maximum isometric muscle strength effect.

2.
Beijing Da Xue Xue Bao ; (6): 108-113, 2023.
Artículo en Chino | WPRIM | ID: wpr-971281

RESUMEN

OBJECTIVE@#To predict the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training based on the modified Wright learning curve model, then to analyze and applicate the learning curve.@*METHODS@#Twelve graduate students participating in standardized dental resident training were selected to prepare the resin maxillary central incisors on phantom head simulators for all ceramic crowns 4 times. The results of preparation were evaluated by 3 prosthetic experts with at least 10 years' experience focusing on the reduction, contour, taper, shoulder, finish line, margin placement, adjacent tooth injury, and preparation time for tooth preparation. The learning rate of tooth preparation was calculated by scores of tooth preparation of 4 times. The learning curve of tooth preparation was predicted based on the modified Wright learning curve model. According to the criteria of standardized training skill examinations for dental residents in Beijing, 80 was taken as the qualified standard score. The minimum training times for tooth preparation to satisfy the qualified standard score (80) was calculated, to analyze the characteristics of learning curve and evaluate the effectiveness of tooth preparation.@*RESULTS@#The scores of 4 tooth preparation were 64.03±7.80, 71.40±6.13, 74.33±5.96, and 75.98±4.52, respectively. The learning rate was (106±4)%, which showed the learning curve an upward trend. There were no significant differences between the qualified standard score and the predicted scores of tooth preparation from the 5th preparation to the 13th preparation (P > 0.05). The predicted score of the 14th preparation was higher than the qualified standard score (P < 0.05).@*CONCLUSION@#The trend of the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training is upward, which predicts the minimum training times higher than the qualified standard score is 14 times.


Asunto(s)
Humanos , Preparación Protodóncica del Diente/métodos , Incisivo , Curva de Aprendizaje , Coronas , Preparación del Diente , Cerámica , Porcelana Dental , Diseño de Prótesis Dental
3.
Beijing Da Xue Xue Bao ; (6): 120-123, 2023.
Artículo en Chino | WPRIM | ID: wpr-971283

RESUMEN

OBJECTIVE@#To preliminarily explore the applicable scenarios of an intraoral camera to assist oral anatomical landmarks recognition, so as to improve the clinical diagnosis and treatment mode, cultivate the concept of caring for patients, strengthen doctor-patient communication, assist experts to teach, and improve the clinical diagnosis and efficacy rate.@*METHODS@#A new type of an intraoral camera was applied in the recognition of oral anatomy landmarks and four application scenarios were developed, namely: (1) clinical diagnosis and treatment scenarios, in which doctors used intraoral camera to conduct a comprehensive examination of patients in the mouth and take videos and photos; (2) doctor-patient communication scenarios, when the doctor told the patient about the treatment plan, the video or photo taken by the intraoral camera was displayed to the patient; (3) expert teaching scenarios, when the expert used an intraoral camera to teach in the patient's mouth, and the young doctor learned oral anatomical signs on the projection screen, with the study of theoretical lessons; (4) difficult case recording scenarios, in the process of clinical diagnosis and treatment, when encountering difficult cases, you could use intraoral camera to record and take photos for young doctors to discuss, and experts to comment and guide.@*RESULTS@#The application of intraoral camera could: (1) improve the clinical diagnosis and treatment mode and raise the clinical diagnosis and efficacy rate; (2) stimulate young doctors' interest in learning, use intraoral camera in assessments, and skillfully combine theoretical knowledge of anatomical landmarks with clinical practice, so as to improve the teaching effect; (3) cultivate, through self or mutual use, the concept of caring for patients and reinforce the importance of gentle operation; (4) strengthen doctor-patient communication. Doctors could communicate with patients more visually, so that the patients could better understand their own situation, and strengthen the patients' trust in the doctors.@*CONCLUSION@#Intraoral camera can assist oral clinical diagnosis and treatment, such as the recognition of oral anatomical landmarks. It plays a certain role in promoting the improvement of clinical diagnosis and treatment mode, stimulating learning interest, cultivating the concept of caring for patients, and enhancing doctor-patient communication.


Asunto(s)
Humanos , Relaciones Médico-Paciente , Médicos , Comunicación , Boca , Aprendizaje
4.
Chinese Journal of Stomatology ; (12): 414-421, 2023.
Artículo en Chino | WPRIM | ID: wpr-986088

RESUMEN

Objective: To provide a new solution for the digital design of nasal prostheses, this study explores the three-dimensional (3D) facial morphology completion method for external nasal defects based on the non-rigid registration process of 3D face template. Methods: A total of 20 male patients with tooth defect and dentition defect who visited the Department of Prosthodontics, Peking University School and Hospital of Stomatology from June to December 2022 were selected, age 18-45 years old. The original 3D facial data of patients were collected, and the 3D facial data of the external nose defect was constructed in Geomagic Wrap 2021 software. Using the structured 3D face template data constructed in the previous research of the research group, the 3D face template was deformed and registered to the 3D facial data of external nose defect (based on the morphology of non-defective area) by non-rigid registration algorithm (MeshMonk program), and the personalized deformed data of the 3D face template was obtained, as the complemented facial 3D data. Based on the defect boundary of the 3D facial data of the external nose defect, the complemented external nose 3D data can be cut out from the complemented facial 3D data. Then the nasofacial angle and nasolabial angle of the complemented facial 3D data and the original 3D facial data was compared and analyzed, the ratio between the nose length and mid-face height, nose width and medial canthal distance of the complemented facial 3D data was measured, the edge fit between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was evaluated, and the morphological difference of the nose between the complemented external nose 3D data and the original 3D facial data was analyzed. Results: There was no significant statistically difference (t=-0.23, P=0.823; Z=-1.72, P=0.086) in the nasofacial angle (28.2°±2.9°, 28.4°±3.5° respectively) and nasolabial angle [95.4°(19.2°), 99.9°(9.5°) respectively] between the 20 original 3D facial data and the complemented facial 3D data. The value of the ratio of nose length to mid-face height in the complemented facial 3D data was 0.63±0.03, and the value of the ratio of nose width to medial canthal distance was 1.07±0.08. The curve deviation (root mean square value) between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was (0.37±0.09) mm, the maximum deviation was (1.14±0.32) mm, and the proportion of the curve deviation value within±1 mm was (97±3)%. The distance of corresponding nose landmarks between the complemented facial 3D data and the original 3D facial data were respectively, Nasion: [1.52(1.92)] mm; Pronasale: (3.27±1.21) mm; Subnasale: (1.99±1.09) mm; Right Alare: (2.64±1.34) mm; Left Alare: (2.42± 1.38) mm. Conclusions: The method of 3D facial morphology completion of external nose defect proposed in this study has good feasibility. The constructed complemented external nose 3D data has good facial coordination and edge fit, and the morphology is close to the nose morphology of the original 3D facial data.

5.
Artículo en Chino | WPRIM | ID: wpr-991166

RESUMEN

Atherosclerotic cardiovascular disease(ASCVD)frequently results in sudden death and poses a serious threat to public health worldwide.The drugs approved for the prevention and treatment of ASCVD are usually used in combination but are inefficient owing to their side effects and single therapeutic targets.Therefore,the use of natural products in developing drugs for the prevention and treatment of ASCVD has received great scholarly attention.Andrographolide(AG)is a diterpenoid lactone compound extracted from Andrographis paniculata.In addition to its use in conditions such as sore throat,AG can be used to prevent and treat ASCVD.It is different from drugs that are commonly used in the prevention and treatment of ASCVD and can not only treat obesity,diabetes,hyperlipidaemia and ASCVD but also inhibit the pathological process of atherosclerosis(AS)including lipid accumulation,inflammation,oxidative stress and cellular abnormalities by regulating various targets and pathways.However,the pharmaco-logical mechanisms of AG underlying the prevention and treatment of ASCVD have not been corrobo-rated,which may hinder its clinical development and application.Therefore,this review summarizes the physiological and pathological mechanisms underlying the development of ASCVD and the in vivo and in vitro pharmacological effects of AG on the relative risk factors of AS and ASCVD.The findings support the use of the old pharmacological compound('old bottle')as a novel drug('novel wine')for the pre-vention and treatment of ASCVD.Additionally,this review summarizes studies on the availability as well as pharmaceutical and pharmacokinetic properties of AG,aiming to provide more information regarding the clinical application and further research and development of AG.

6.
Chinese Journal of Stomatology ; (12): 101-106, 2022.
Artículo en Chino | WPRIM | ID: wpr-935836

RESUMEN

In dental esthetic rehabilitation, patients pay great attention to the rehabilitative esthetic effect before teeth preparation, and this is also an important content of doctor-patient communication. Along with the development and combined application of intraoral scan, three-dimensional (3D) face scan, digital design, numerical control machining and 3D printing technology, digital technology is gradually applied to the virtual simulated design before irreversible operation in dental esthetic rehabilitation. Digital technology can be used in dentistry to simulate the esthetic outcome in advance, to assist communication among the dentists, patients and dental technicians, and to realize satisfactory outcome in the final restorations precisely, which, as a result, increases the clinical satisfaction. This review focuses on the application of digital virtual simulated design technology in dental esthetic rehabilitation, analyzes the current research development, deficiency and future prospects, so as to provide guidance for clinical diagnosis and treatment.


Asunto(s)
Humanos , Diseño Asistido por Computadora , Estética Dental , Cara , Impresión Tridimensional , Preparación del Diente
7.
Beijing Da Xue Xue Bao ; (6): 193-199, 2022.
Artículo en Chino | WPRIM | ID: wpr-936134

RESUMEN

OBJECTIVE@#To automatically construct lips symmetry reference plane (SRP) based on posed smile, and to evaluate its advantages over conventional digital aesthetic design.@*METHODS@#Eighteen subjects' three-dimensional facial and dentition data were gathered in this study. The lips SRP of experimental groups were used with the standard weighted Procrustes analysis (WPA) algorithm and iterative closest point (ICP), respectively. A reference plane defined by experts based on regional ICP algorithm, served as the truth plane. The angle error values between the lips SRP of WPA algorithm in the experimental groups and the truth plane were evaluated in this study, and the lips SRP of ICP algorithm of the experimental groups was calculated in the same way. The lips SRP based on posed smile as a reference for aesthetic design and evaluate preliminary clinical application.@*RESULTS@#The average angle error between the lips SRP of WPA algorithm and the truth plane was 1.78°±1.24°, which was smaller than that between the lips SRP of ICP and the truth plane 7.41°±4.31°. There were significant differences in the angle errors among the groups (P < 0.05). In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile and the original symmetry plane by re-ference compared with the prosthetic design, the subjects' scores on the lips SRP of WPA algorithm based on posed smile (8.48±0.57) were higher than those on the original symmetry plane (5.20±1.31).@*CONCLUSION@#Automatically constructing the lips SRP of WPA algorithm based on posed smile was more accurate than ICP algorithm, which was consistent with the truth plane. Moreover, it can provide an important reference for oral aesthetic diagnosis and aesthetic analysis of the restoration effect. In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile can improve the patients' satisfaction in esthetic rehabilitation.


Asunto(s)
Humanos , Estética Dental , Labio , Sonrisa , Diente , Flujo de Trabajo
8.
Chinese Journal of Digestion ; (12): 83-88, 2022.
Artículo en Chino | WPRIM | ID: wpr-934135

RESUMEN

Objective:To evaluate the safety and clinical efficacy of the novel double disc-shaped gastrointestinal occluder (hereinafter referred to as occluder) in treatment of refractory tracheoesophageal fistula (TEF).Methods:From July 1, 2020 to January 31, 2021, 10 patients with refractory TEF treated with occluder at Department of Gastroenterology, the First Affiliated Hospital with Nanjing Medical University were collected. The patients′ clinical data such as gender, age, body mass index and fistula diameter were recorded. The success rate of operation, intraoperative and postoperative complications, operation time, postoperative hospital stay, efficacy of fistula closure and postoperative recovery were analyzed. The Karnofsky score and body mass index of patients 1 month and 3 months after operation were compared with those before operation for curative effect evaluation. Paired t test was used for statistical analysis. Results:Among the 10 TEF patients, there were 7 males and 3 females, the median age was 64.5 years old (ranged from 49.0 to 78.0 years old), the body mass index was (18.0±2.5) kg/m 2 and the diameter of the fistula was (1.2±0.6) cm. Occluder placement was successful in all patients. The operation time was (17.6±7.8) min (ranged from 7.0 to 30.0 min). Two cases had little bleeding during the operation, and there was no bleeding after the operation. The postoperative hospital stay was (5.9±4.0) d (ranged from 1.0 to 12.0 d). Among the 10 TEF patients, fistula of 5 patients were completely blocked, 4 cases were partially blocked and 1 case was ineffectively blocked, the effective rate of blocking was 9/10. One month follow-up after operation showed that the symptoms of choking and coughing during eating were significantly improved in 9 patients, and the symptoms of choking and coughing during eating were significantly improved in 1 patient after waist diameter of 12 mm occluder was replaced with the occluder of 15 mm. The 3-month follow-up after operation showed that the occluders were in the right place in 8 patients, the occluder was displaced in 1 patient and the occluder was removed and treated with enteral nutrition. One patient died due to the recurrence of esophageal cancer. The Karnofsky score of TEF patients 3 months after operation and the body mass index of TEF patients 1 month and 3 months after operation were higher than those before operation (70.0±34.0 vs. 46.0±10.7, (19.32±2.59) and (19.73±2.92) kg/m 2 vs. (18.03±2.50) kg/m 2), and the differences were statistically significant ( t=-3.09, -2.37 and -2.82, all P<0.05). Conclusions:Gastrointestinal occluder is safe and effective in the treatment of refractory TEF.

9.
Beijing Da Xue Xue Bao ; (6): 402-405, 2021.
Artículo en Chino | WPRIM | ID: wpr-942194

RESUMEN

OBJECTIVE@#To evaluate the effects of different edge compensation angles on the fracture strength of multilayer zirconia all-ceramic crowns and traditional uniform zirconia all-ceramic crowns.@*METHODS@#The resin tooth preparation specimen of the mandibular first molar with a knife-edge was fabricated. A 3D digital model of the specimen was obtained by scanning it with a 3D dental model scanner. The 3D digital model was imported into computer aided design (CAD) software, and three 3D digital models of the full crown with the same surface shape are designed with the edge compensation angles of 30°, 45° and 60°, respectively. Then, the designed 3D digital model is imported into computer aided manufacturing (CAM) software. Three kinds of multilayer and homogeneous zirconia all-porcelain crowns with different edge compensation angles were fabricated, 10 each for a total of 60. The fracture load of each crown was measured under the electronic universal testing machine.@*RESULTS@#Fracture load of multilayer and uniform zirconia all-ceramic crowns, (4 322.86±610.07) N and (5 914.12±596.80) N in the 30° group, (5 264.82±883.76) N and (5 220.83±563.38) N in the 45° group and (4 900.42±345.41) N and (5 050.22±560.24) N in the 60° group, respectively. The fracture load of multi-layer zirconia all-ceramic crowns in the 30° group was significantly lower than that of homogeneous zirconia all-ceramic crowns(P < 0.05); there was no statistical significance in 45° group and 60° group(P>0.05). In the multi-layer zirconia all-ceramic crowns: the fracture load of the 30° group was significantly lower than that of the 45° group (P < 0.05); there was no significant difference between the 30° group and the 60° group, the 45° group and the 60° group (P>0.05).In uniform zirconia full crown group: the 30° group was higher than the 45° group, the 30° group was higher than the 60° group (P < 0.05), and there was no significant difference between the 45° group and the 60° group (P>0.05).@*CONCLUSION@#The fracture loads of three kinds of uniform and multilayer zirconia all ceramic crowns with different edge compensation angles can meet the clinical requirements. A smaller edge compensation angle is recommended when using traditional zirconia all-ceramic crowns, while 45° is recommended when using multi-layer zirconia all-ceramic crowns.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Coronas , Porcelana Dental , Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Resistencia Flexional , Ensayo de Materiales , Circonio
10.
Beijing Da Xue Xue Bao ; (6): 406-412, 2021.
Artículo en Chino | WPRIM | ID: wpr-942195

RESUMEN

OBJECTIVE@#To compare the differences and indications of three evaluation methods for fitness evaluation of removable partial denture (RPD).@*METHODS@#A RPD was fabricated and seated on the stone cast of a partially edentulous mandible, and the spaces between RPD and stone cast were recorded with polyvinyl siloxane (PVS) impression material forming PVS replicas. Using cross sectional measurement, the average thicknesses of PVS replicas were measured under stereomicroscope with different numbers of selected measuring points in the denture base, major connector, occlusal rest of the RPD, and the average thicknesses of the PVS replicas measured with different numbers of measuring points were compared using one-way analysis of variance (ANOVA) and independent sample t test. Three kinds of method, including cross sectional measurement, three-dimensional analysis on the stone cast, and three-dimensional analysis on the polyether cast, were applied to measure the average thicknesses of the PVS replicas, and the average thicknesses of the PVS replicas measured by these three evaluation methods were compared with ANOVA.@*RESULTS@#For cross sectional measurement, statistically significant differences were found in the average thicknesses of the PVS replicas in the denture base and the major connector among the different numbers of measuring points (P < 0.05), but no differences were found in the average thicknesses of the PVS replicas in the occlusal rest (P>0.05). There were significant differences among the average thicknesses of the PVS replicas measured by these three evaluation methods in each component of the RPD (P < 0.01). The average thickness measured by three-dimensional analysis on the stone cast and three-dimensional analysis on polyether cast were smaller than that measured by cross sectional measurement (P < 0.05). And there were no differences between the average thicknesses of PVS replicas measured by three-dimensional analysis on stone cast and three-dimensional analysis on polyether cast (P>0.05).@*CONCLUSION@#For cross sectional measurement, the average thickness of the PVS replicas was influenced by the number of measuring points, and the measurement accuracy of cross sectional measurement was not reliable enough. Three-dimensional analysis on stone cast which is suitable for evaluation in vitro and three-dimensional analysis on polyether cast which is suitable for evaluation in vivo can evaluate the fitness of RPD more comprehensively and effectively than that of cross sectional measurement.


Asunto(s)
Diseño Asistido por Computadora , Estudios Transversales , Dentadura Parcial Removible , Ejercicio Físico , Proyectos de Investigación
11.
Artículo en Chino | WPRIM | ID: wpr-872880

RESUMEN

Gout is the second largest metabolic disease after diabetes, with a high incidence worldwide. Gout is a common and complex arthritic disease that, if left untreated, can damage joints and, in severe cases, lead to kidney stones and even life-threatening kidney failure. Although western medicine has also made significant achievements in the treatment of gout, it is often accompanied by gastrointestinal reactions, liver injury and other adverse reactions, and is prone to relapse after drug withdrawal, making the radical treatment of gout a difficult problem. Traditional Chinese medicine (TCM) used in gout have relatively long history, TCM has the characteristics of multiple ingredients targets, not only can produce related enzyme activity by inhibiting the uric acid(UA) and lowering uric acid generation, also can reduce uric acid by promoting uric acid excretion, except the uric acid reduction most applied in gout neighborhood of TCM can effectively reduce joint inflammation. TCM is mild, and the incidence of adverse reactions in the treatment of gout is significantly lower than that of western medicine. Some TCM can even play a role while protecting the kidney, so TCM is expected to solve the problem of treating gout. In recent years, a large number of studies have been conducted on the application of TCM in the gout neighborhood at home and abroad. By summarizing the studies on the application of TCM in the gout disease in the past 10 years, the mechanism of action and material basis have been summarized and analyzed, in the hope of providing references for the studies on the prevention and treatment of gout by TCM.

12.
Artículo en Chino | WPRIM | ID: wpr-872959

RESUMEN

Objective::To compare the difference of the content of volatile oil and the total relative percentage of phthalein compounds in volatile oil among different parts about Ligusticum chuanxiong, or among different decoction pieces with different processing methods. Method::Steam distillation was used(in the extraction of volatile oil.The chemical constituents of the volatile oil were identified by GC-MS analysis, and relative content of each component was determined by normalization method. Result::The contents of volatile oil in different parts were obviously different, and the order of the contents from high to low was rhizome(1.12%)>fibrous root(0.75%)>aerial part(0.41%). The GC-MS analysis similar compounds find in the three different volatile oils, and the order of total relative percentages of phthalein compounds from high to low was roots(83.29%)>rhizomes(44.5%)>aerial part(39.95%). On the other hand, the volatile oil content of three different Chuanxiong Rhizoma pieces with different processing methods was C(0.87%)>A(0.75%)>B(0.7%). The total relative percentages of phthalein compounds analyzed by GC-MS was C(79.14%)>A(73.09%)>B(67.29%). Conclusion::The content of phthalein compounds in the volatile oil of fibrous root was higher than that of rhizome, thus it can be appropriately used.The volatile oil content and chemical composition of different Chuanxiong Rhizoma pieces were significantly different.The content of volatile oil and phthalein compounds in fresh-cut Chuanxiong Rhizoma pieces were the most high, thus fresh-cutting can be used as a new processing method for Chuanxiong Rhizoma pieces.

13.
Artículo en Chino | WPRIM | ID: wpr-873167

RESUMEN

Objective:To analyze and compare the fishy components in raw, stir-fried, liquorice-processed, vinegar-processed and wine-processed products of Pheretima aspergillum, and explore the material basis and processing principle of fishy smell of P. aspergillum. Method:Heracles Ⅱ ultra-fasted gas chromatography electronic nose technology combined with chemometrics was used for the overall analysis of volatile components in raw P. aspergillum and its processed products. Headspace gas chromatography-mass spectrometry (HS-GC-MS) was used to analyze and identify the volatile compositions in the raw products and processed products. Gas chromatographic conditions were as following:temperature program (initial temperature at 60 ℃, kept for 5 min, up to 120 ℃ with the heating rate of 3 ℃·min-1, and then up to 230 ℃ with the heating rate of 10 ℃·min-1 and finished), the inlet temperature at 280 ℃, high purity helium as the carrier gas, the flow rate of 1.0 mL·min-1, the split ratio of 20∶1. Mass spectrum conditions were as following:electron impact ionization (EI), electron collision energy of 70 eV, ion source temperature of 230 ℃, quadrupole temperature at 150 ℃, scanning range of m/z 50-550. The relative content of each component was calculated by peak area normalization. Result:Principal component analysis (PCA) and discriminant factor analysis (DFA) of the electronic nose showed that the raw products and its processed products could be clearly distinguished from each other. Among them, the difference between raw products and stir-fried, liquorice-processed products was small, but the difference between raw products and vinegar-processed, wine-processed products was large. A total of 25, 27, 22, 26 and 33 components were respectively identified from raw, stir-fried, liquorice-processed, vinegar-processed and wine-processed products of P. aspergillum, there were 13 common components in these products, including 4 aldehydes (isovaleraldehyde, 2-methylbutyraldehyde, hexanal, benzaldehyde), 2 ketones (2-heptanone, 2-tridecanone), 1 carboxylic acid (lauric acid), 4 heterocyclic compounds (2-methylpyrazine, 2,5-dimethyl pyrazine, 2-pentylfuran, 2-ethyl-6-methyl pyrazine), 1 amine (trimethylamine) and 1 alcohol (1-octen-3-ol). Conclusion:The odorous components in the raw products are mainly derived from aldehydes (isovaleraldehyde, 2-methylbutyraldehyde, isobutyraldehyde, 2-ethylhexanal, hexanal) and amines (trimethylamine). Odorous components of P. aspergillum can be reduced effectively by stir-fried and liquorice, vinegar, wine processing, while flavoring substances can be increased by wine processing to cover its ugly odor. This paper can provide scientific basis for the deodorization of P. aspergillum by processing, and also provide reference for the analysis and correction of ugly odor of other animal medicines.

14.
China Pharmacy ; (12): 1223-1227, 2020.
Artículo en Chino | WPRIM | ID: wpr-821611

RESUMEN

OBJECTIVE:To compare the c ontents of 6 kinds of ester alkaloids in raw aconite and 5 kinds of salt-processed products,and to provide reference for the optimization of salt-processing technology. METHODS :Processed with bittern , magnesium chloride ,sodium chloride ,calcium chloride and potassium chloride as excipients ,and HPLC method were adopted to determine the contents of 6 kinds of ester alkaloids in raw aconite and 5 kinds of salt-processed products. The effect/toxicity ratio and toxicity component index were used to evaluate the effect and toxicity of raw aconite and 5 kinds of salt-processed products. RESULTS: The linear range of benzoylneoaconitine , benzoylhypoconitine, benzoylaconitine, neoaconitine, aconitine and hypoconitine were 2.440-24.40,2.240-22.40,2.020-20.20,2.780-27.80,2.240-22.40,2.240-22.40 μg/mL(r≥0.999 0). RSDs of precision,stability and repeatability tests were all less than 2%. The recovery rates were 102.13%-104.87%(RSD=0.98%,n= 6),100.00%-105.00%(RSD=2.02%,n=6),95.00%-99.29%(RSD=1.77%,n=6),100.41%-104.58%(RSD=1.78%,n= 6),98.87%-99.90%(RSD=0.41%,n=6),100.20%-104.00%(RSD=1.55,n=6),respectively. The contents of total alkaloids in order from the largest to the smallest was as follows :raw aconite >processed products of sodium chloride >processed products of bittern >processed products of potassium chloride >processed products of calcium chloride >processed products of magnesium chloride. The order of effect/toxicity ratio was processed products of potassium chloride >processed products of magnesium chloride>processed products of sodium chloride >processed products of calcium chloride >processed products of bittern >raw aconite. The order of toxicity component index was raw aconite >processed products of sodium chloride >processed products of bittern>processed products of calcium chloride >processed products of potassium chloride >processed products of magnesium chloride. CONCLUSIONS :Using 5 kinds of salt as excipients ,the proce ssing technology has different degrees of “efficacy enhancing and toxicity reducing ”effect. Among them ,magne- sium chloride ,potassium chloride and calcium chloride are better for processing and can be used for processing aconite.

15.
Beijing Da Xue Xue Bao ; (6): 187-192, 2020.
Artículo en Chino | WPRIM | ID: wpr-941987

RESUMEN

OBJECTIVE@#To explore the possibility of the Smile Lite MDP (Smile Lite Mobile Dental Photograph) portable dental photography system applying in anterior teeth aesthetic photography, and to provide the chance to simplify aesthetic photography process and facilitate communication among patients, dentists and dental technitians.@*METHODS@#The Smile Lite MDP photography system combined with the smartphone were used to photograph the front occlusal phase photos of anterior teeth. The photographic conditions including the color temperature parameter, the Smile Lite MDP light position and the intensity settings were explored. The best photographic conditions were chosen by blind evaluation within experienced dentists and technicians through the method of the visual analogue scale/score (VAS) evaluation, which went through statistical analysis to figure out the optimum photograghic conditions. Smile Lite MDP photography system was used to photograph the front occlusal phase photos of anterior teeth under the optimum parameter by different magnifications. The width/height ratio of the central incisor and the front width ratio of the upper anterior teeth in those photos were measured and calculated respectively. The accuracy of the anterior teeth photos taken by Smile Lite MDP photography system was analyzed based on the photographs taken by digital single lens reflex (DSLR) camera.@*RESULTS@#The optimum color temperature parameter of Smile Lite MDP portable camera system was 5 000 K, the optimum magnification was 4 times, the best light position was the side lights of Smile Lite MDP, the optimum intensity of lights was 2 grades. Photos taken by the optimum parameters won the highest score during the VAS evaluation and the result of statistical analysis had significant difference compared with other groups (P<0.05). When comparing the photos of the upper anterior teeth taken by the Smile Lite MDP portable photography system using 4 times magnification or by DSLR using the standard parameters, there was no significant difference neither in the width/hieght ratio of the central incisor nor in the front width ratio of the upper anterior teeth (P>0.05).@*CONCLUSION@#The Smile Lite MDP portable dental photography system applying in anterior teeth aesthetic analysis photography was capable to show the color and shape of anterior teeth in an accurate way by using the right photography parameters. Therefore, Smile Lite MDP portable dental photography system was considered to be a simple and easy photographic tool in clinical work.


Asunto(s)
Humanos , Estética , Estética Dental , Incisivo , Fotograbar , Sonrisa
16.
Beijing Da Xue Xue Bao ; (6): 390-394, 2020.
Artículo en Chino | WPRIM | ID: wpr-942017

RESUMEN

Fabrication of conventional complete dentures involves a complex restoration method, requiring significant time and typically involving primary impressions, definitive impressions, jaw relation records, clinic try-in, and complete denture placement, which has been used for nearly a century without change. A novel digital system named Functionally Suitable Denture (FSD) was researched and developed so as to reduce clinical steps, operation difficulties and errors of complete denture restoration. It pioneered a unique diagnostic complete denture aided by computer aided design (CAD) & 3D printing, by which, the functional impression, jaw relation, and try-in (3 steps) were simplified to 1 step, thus the number of visits to the dentist was reduced by 2 times. Moreover, for the first time, it put forward a CAD software of template matching based on the expert design, which was an efficient and intelligent design scheme, and the excellent denture experts' experience and skills could be inherited and iterated. The system included the 3D scanner with appropriate accuracy and high efficiency, the CAD software, the special 3D printer and process software, and the innovative clinical operation process. The Patent Cooperation Treaty (PCT) patent international search report showed that all the 15 claims of the technology were of novelty, creativity and industrial utility. All the digital products were independently developed and made by Peking University School and Hospital of Stomatology, China. The design and manufacture process of denture prosthesis was fast, simple and accurate. At the same time, personalized functional and aesthetic matching of the patients after wearing prosthesis was realized. It effectively solved the global problems of "slow, difficult and inaccurate" of the traditional manual technology of complete denture, and brought good news to edentulous patients. Compared with the traditional complete denture treatment, FSD system has a wide range of applications for different types of edentulous patients, including those with severe resorption of the alveolar ridge or a high occlusal force. Furthermore, the low-cost of 3D printers, compared with expensive milling machines, may make the approach more accessible. This review describes that our research is related to the development of the FSD system, including multi-source data acquisition technology, three generations of complete denture design software, 3D printing systems of individual tray and complete denture pattern, the clinical and laboratory operation process of the FSD system.


Asunto(s)
Humanos , China , Diseño Asistido por Computadora , Creatividad , Dentadura Completa , Boca Edéntula
17.
Beijing Da Xue Xue Bao ; (6): 62-68, 2020.
Artículo en Chino | WPRIM | ID: wpr-942142

RESUMEN

OBJECTIVE@#To explore the preliminary application of "biocopy function" in digital technology of temporary crown in severe tooth attrition, so as to reduce the difficulty of final restoration adjustment in severe tooth wear cases, and save clinical time.@*METHODS@#Twelve patients aged between 40 and 65 years with severe tooth attrition were recruited in this study. The experimental group (6 cases, 3 females and 3 males) used the method of digital copy of temporary restoration shape when making the final restoration, and the control group (6 cases, 3 females and 3 males) used the traditional method to make the final restoration. The mean time of central occlusal adjustment and protrusive and lateral occlusal adjustment of each crown, the number of follow-up visits of the patients were recorded and statistically analyzed. The occlusal comfort of the first and the third months after wearing the prosthesis was evaluated by the patients, and the difference of the occlusal comfort of the final prosthesis made by the two methods was compared (the full score was 10 points). The occlusal adjustment time and occlusal comfort score were used as measurement data. Single sample t test was used. The number of follow-up visits was count data. Rank sum test was used for non-normal continuous variables.@*RESULTS@#The mean occlusal time of each crown adjustment in the experimental group was significantly lower than that in the control group (P < 0.01), and the median number of follow-up visits in the experimental group was lower than that in the control group (P < 0.01). The average occlusal comfort score of the experimental group was higher than that of the control group at the first time (P < 0.01). After three months of crown wearing, the median occlusal comfort score of the experimental group was higher than that of the control group (P < 0.05).@*CONCLUSION@#In the case of severe tooth attrition, it is feasible to use the "biocopy function" in the design software to design the final prosthesis, which is conducive to reduce the difficulty of adjustment and achieve predictable functional and aesthetic effects, which is of great significance to save clinical time and improve the accuracy of restoration.


Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño Asistido por Computadora , Coronas , Diente
18.
Beijing Da Xue Xue Bao ; (6): 105-110, 2019.
Artículo en Chino | WPRIM | ID: wpr-941778

RESUMEN

OBJECTIVE@#To establish a complete workflow of digital design and manufacturing occlusal splint for sleep bruxism, which can be preliminarily applied in clinical use, thus observe the clinical efficacy.@*METHODS@#Twenty-four patients with sleep bruxism were recruited in the study and randomly divided into two groups by using random number tables. Digital-occlusal-splint (experimental group) treatment plan and traditional-occlusal-splint (control-group) treatment plan were carried out for each group, respectively. For experimental group, digital models of patients' both dental arches and the occlusion relationship after elevation were captured using an intraoral scanner. The occlusal splint was carried out by computer aided design/computer aided manufacturing (CAD/CAM), including splint designing and milling. For control group, the traditional soft occlusal splint was fabricated by vacuum laminator. The two kinds of occlusal splints were tried in the patients from each group, and the occlusal contacts were tested respectively by T-scan analysis system, which recorded the changes of occlusal indicators in the two groups. The retention, appearance and occlusal comfort degree were evaluated by the two groups of patients. Mann-Whitney test was performed with IBM SPSS 20.0 software, and bilateral test was performed. P<0.05 was considered to be statistically significant.@*RESULTS@#The complete workflow of digital design and manufacturing occlusal splint was successfully established. During the clinical use, there was no statistical difference in the retention evaluation of two kinds of occlusal splints between the two groups of patients (Z=-0.538, P=0.590). The appearance score (Z=2.038, P=0.042) and the occlusal comfort score (Z=-2.579, P=0.010) of the experimental group were higher than those of the control group, with statistically significant differences. The T-scan analysis results showed that only the second molar on both sides of the traditional occlusal splint had occlusal contact in intercupsal position, while the digital occlusal splint had stable and bilaterally balanced contact between the maxillary and mandibular teeth. Furthermore, the occlusal force was uniformly distributed in the experimental group.@*CONCLUSION@#The complete workflow of digital occlusal splint improves the occlusal design, greatly simplifies and optimizes the traditional process of making occlusal splint. This new method is resource-saving and environmental-friendly, and it is able to serve patients more conveniently and efficiently.


Asunto(s)
Humanos , Arco Dental , Oclusión Dental , Ferulas Oclusales , Bruxismo del Sueño , Flujo de Trabajo
19.
Beijing Da Xue Xue Bao ; (6): 335-339, 2019.
Artículo en Chino | WPRIM | ID: wpr-941816

RESUMEN

OBJECTIVE@#To explore a novel method for fabricating removable partial dentures (RPDs) using polyetheretherketone (PEEK) by computer-aided design and computer-aided manufacturing (CAD/CAM) technologies and to evaluate their fits for different assemblies in vitro.@*METHODS@#A standard stone cast of mandibular partial edentulous jaw was scanned using a lab scanner. Based on the digital cast, thirteen complete RPDs were designed combing dental CAD software and reverse engineering software, and then fabricated using PEEK by milling machine. Fits of assemblies were evaluated quantitatively by measuring the spaces between RPDs and casts. The gaps between RPDs and stone casts in different assemblies were duplicated using light-body silicone impression material and then measured using three-dimensional (3D) digital analysis methods in virtue of a dedicated software. Statistically, one-way analysis of variance (ANOVA) was used to compare the difference of gaps among assemblies in different shapes such as occlusal rest, denture base, and major connector. Paired-samples t test was used to compare the gaps difference for the similar shape assemblies in different areas.@*RESULTS@#One-piece PEEK RPDs were successfully designed and fabricated by CAD/CAM, and all the RPDs were well-seated on stone casts. The gaps between occlusal rests and casts [(84.3±23.6) μm] were significantly larger than those of denture bases [(32.5±27.8) μm] and major connectors [(49.9±47.0) μm], which meant that the fits of denture bases and major connectors were better than that of occlusal rests. However, the fits of all assemblies could be accepted clinically. For the similar shape assemblies in different areas, there were no significantly differences for gaps between distal extension denture bases [(25.1±55.3) μm] and non-extensive denture bases [(41.5±17.7) μm]. The gaps of occlusal rests adjacent and nonadjacent to the edentulous space were (86.1±29.8) μm and (80.8±42.1) μm respectively and there were no significantly difference between them either. These results implied that different locations had no apparent effect on the fits of assemblies.@*CONCLUSION@#With the computer-aided design and computer-aided manufacturing technology, PEEK can be used to fabricate one-piece removable partial dentures. And all assemblies of the one-piece PEEK RPDs showed satisfying fits in vitro, indicating a promising clinical application in the future.


Asunto(s)
Benzofenonas , Diseño Asistido por Computadora , Dentadura Parcial Removible , Cetonas , Polietilenglicoles , Polímeros
20.
Beijing Da Xue Xue Bao ; (6): 349-355, 2019.
Artículo en Chino | WPRIM | ID: wpr-941819

RESUMEN

OBJECTIVE@#To design and fabricate edentulous custom trays by chair-side computer-aided design and 3-dimensional printing (CAD/3DP) system of independent research and development and to evaluate their clinical effects based on prosthodontists'satisfaction using the visual analogue scale (VAS).@*METHODS@#Fifteen edentulous patients were randomly recruited by three prosthodontists who passed the unified operating process training. The custom trays for each patient were fabricated using both chair-side CAD/3DP system of independent development and manually conventional method, and the final impressions were made by silicone impression materials (light body). The prosthodontist's satisfaction was surveyed by the three prosthodontists via the questionnaire based on visual analogue scales.@*RESULTS@#In the degree of the prosthodontist's satisfaction of final impressions, the average satisfactions of "try in" (the overall size, shape, convenience, etc.) on the 3DP custom tray made by independent development chair-side system and the manually conventional method were 9.18±0.19 and 8.23±0.22, respectively. The average satisfactions of the border line position (border extensions, frenal notch)were 8.91±0.40 and 7.96±0.23, respectively. The average satisfactions of the stability in border molding were 8.80±0.83 and 8.01±0.81, respectively. The average satisfactions of the quality of final impression (completeness, thickness of impression material, exposure of custom tray, shape of border) were 8.94±0.68 and 7.99±0.42, respectively. The average satisfactions of the difficulty of high quality impression (times of repetition, efficiency) were 9.20±0.37 and 7.88±0.22, respectively. The average satisfactions of the overall satisfaction were 9.11±0.49 and 7.95±0.15, respectively. There was significant difference in the satisfaction of "try in", border line position, stability in border molding, quality of final impression, difficulty of high quality impression, and overall satisfaction between the 3DP custom tray made by chair-side system of independent development and the manually conventional method (P<0.05).@*CONCLUSION@#In the degree of the prosthodontist's satisfaction of final impression, the 3DP custom tray made by chair-side system of independent development is higher than that of the conventional custom tray, and it meets the clinical requirements and can be popularized in clinical application.


Asunto(s)
Humanos , Diseño Asistido por Computadora , Materiales de Impresión Dental , Técnica de Impresión Dental , Boca Edéntula , Impresión Tridimensional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA