Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Acupuncture & Moxibustion ; (12): 303-306, 2022.
Artículo en Chino | WPRIM | ID: wpr-927378

RESUMEN

Based on the thinking of integrative and holistic acupuncture and moxibustion, FU Wen -bin proposes to treat depression complicated with obsessive-compulsive disorder from perspective of heart and gallbladder. In clinical practice, the treatment pattern of "acupuncture at the top priority, followed by moxibustion, and consolidation at the end" is applied, acupuncture, refined moxibustion, intradermal needle and other therapies are comprehensively adopted, acupoints on the heart meridian, pericardium meridian and gallbladder meridian are selected or back-shu points and front-mu points of the heart, gallbladder and pericardium are matched, and the acupoints on the conception vessel and governor vessel and with the functions of tonifying kidney and regulating qi are added to calm the heart and tranquilize the mind, so as the symptoms of depression and obsessive-compulsive can be effectively relieved.


Asunto(s)
Humanos , Depresión/terapia , Vesícula Biliar , Meridianos , Moxibustión , Trastorno Obsesivo Compulsivo
2.
China Journal of Chinese Materia Medica ; (24): 2345-2348, 2015.
Artículo en Chino | WPRIM | ID: wpr-337932

RESUMEN

To establish an EDTA complexation extraction pretreatment combining with GFAAS method for the determination of residual aluminium ion in Huoxiang zhengqi pellets without digestive treatment, systematical investigation was made on sample preparation, and EDTA was used for the complexation extraction of residual aluminium ion in samples. The pH, concentration and volume of extraction solution, the temperature and time of microwave extraction, and graphite furnace temperature program were investigated. The results were compared with the microwave digestion. It was showed that, 0.1 g of sample weight was added in 20 mL 0.05 mol x L(-1) EDTA solution (pH 3.5), followed by heating at 150 degrees C for 10 min in the microwave extraction device. The determination of GFAAS was performed at optimized detection wavelength (257.4 nm) as well as graphite furnace temperature program, the detection limits and quantification limits were 2.37 μg x L(-1) and 7.89 μg x L(-1), respectively. The precision (RSD) was less than 2.3%. The average recovery was 96.9% -101%. The present method is easy, rapid and accurate for the determination of residual aluminium ion in Huoxiang zhengqi pellets.


Asunto(s)
Aluminio , Química , Contaminación de Medicamentos , Medicamentos Herbarios Chinos , Química , Ácido Edético , Química , Grafito , Química , Espectrofotometría Atómica , Métodos , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA