Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Hospital Administration ; (12): 562-565, 2019.
Artículo en Chino | WPRIM | ID: wpr-756665

RESUMEN

Objective To make a cost-effectiveness analysis for stereotactic radiotherapy and intensity-modulated radiotherapy using linear accelerators against malignant tumors, then to provide references for choosing a more cost-effective radiotherapy for the patient. Methods Basic information of patients subject to radiotherapy(gender, age, date of admission, days of hospital stay), hospitalization cost, admission diagnosis, clinical outcomes among others of 320 patients with malignant tumors(lung tumor, head and neck tumor, bone metastases, liver tumor) were collected from Hubei, Guangxi and Fujian provinces. The cost of hospitalized radiotherapy and treatment effect of these patients were compared to identify the more cost effective of the two methods. Results The effective rates of stereotactic radiotherapy and intensity-modulated radiotherapy were 99.1% (108/109) and 97.2% (205/211) respectively, and the difference was not significant( P>0.05). The average hospitalization cost of treatment of the two groups was 37 545.56 yuan and 48 159.05 yuan respectively; the cost-effectiveness ratio was 37 886.54 and 49 546.35 respectively. Conclusions The short-term effects of stereotactic and intensity-modulated radiotherapy are similar, but the cost of intensity-modulated radiotherapy is higher. The minimum cost analysis shows that stereotactic radiotherapy is more cost effective.

2.
Chinese Journal of Medical Instrumentation ; (6): 230-234, 2019.
Artículo en Chino | WPRIM | ID: wpr-772519

RESUMEN

OBJECTIVE@#Providing a risk assessment method for the implementation of radiotherapy to identify possible risks in the implementation of the treatment process, and proposing measures to reduce or prevent these risks.@*METHODS@#A multidisciplinary expert evaluation team was developed and the radiotherapy treatment process flow was drawn. Through the expert team, the failure mode analysis is carried out in each step of the flow chart. The results were summarized and the (risk priority ordinal) score was obtained, and the quantitative evaluation results of the whole process risk were obtained.@*RESULTS@#One hundred and six failure modes were obtained, risk assessment of (20%) high risk failure model are 22 and severity (≥ 8) high risk failure model are 27. The reasons for the failures were man-made errors or hardware and software failures.@*CONCLUSIONS@#Failure mode and effect analysis can be used to evaluate the risk assessment of radiotherapy, and it provides a new solution for risk control in radiotherapy field.


Asunto(s)
Análisis de Modo y Efecto de Fallas en la Atención de la Salud , Medición de Riesgo
3.
Chinese Medical Equipment Journal ; (6): 38-42, 2017.
Artículo en Chino | WPRIM | ID: wpr-511348

RESUMEN

Objective To analyze the history and present situation of international medical device with visualization softwareto provide references for medical device development in China.Methods CiteSpace visualization software was used to explore international literatures related to medical device from the aspects of yearly quantity,research direction,research organization,quoted literature and etc from 2005 to 2014.Results Medical device drew increasing attention from corresponding researchers,whose development depended on international cooperation.Medical device related closely to engineering and medicine,and had to paid attention to informatization and clinical requirements.Conclusion CiteSpace software is of great value for the study on medical device.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA