Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Modern Laboratory Medicine ; (4): 156-157,161, 2016.
Artículo en Chino | WPRIM | ID: wpr-604199

RESUMEN

Objective When detecting the blood C peptide by chemiluminescence method,used had confronted the lack of qual-ity control.This paper examines the feasibility of self-made C peptide quality control as indoor quality control products. Methods From the serum of diabetic patients and health examination,C peptide low values(concentration around the 1.20 ng/ml)and high value(concentration around the 12.0 ng/ml)were collected,excluding hemolysis,jaundice and tallow ser-um,preventing bacterial contamination,hepatitis B surface antigen,hepatitis C virus,human immunodeficiency virus indica-tors are negative;then these serum was mixed respectively,embalmed,packaged,-20 DEG preserved.The performance e-valuation of the C peptide mixed serum was carried out using SIEMENS’s C peptide reagent kit.Results Low value,high value of two levels of serum C peptide quality control in batch imprecision respectively were 4.46% and 4.15% respective-ly.Day not precision respectively were 6.00%,5.56%,-20 DEG saved stability for at least 6 months (P>0.05).Com-pared with six months by analysis of variance,F value of the low and high values were 0.665,0.602,P values were 0.471, 0.568 and the difference was not statistically significant (P>0.05),but the difference among bottles was no significant. Conclusion Two levels value of the C peptide in self-made preserved at -20 DEG can meet the requirements of internal quality control products.

2.
International Journal of Laboratory Medicine ; (12): 2231-2232, 2014.
Artículo en Chino | WPRIM | ID: wpr-456063

RESUMEN

Objective To investigate the preparation of the internal quality controls for urinary retinal binding protein(RBP)de-tected by the latex enhanced immunoturbidimetry assay and its performance evaluation.Methods The urine specimens from the pa-tients with nephropathy and healthy people with physical examination were collected,centrifuged by 3 500 r/min for removing sedi-ment,urinary RBP levels were adjusted to the low value for healthy population and the high value for the patients with nephropa-thy;then conducted the anticorrosion,packed and stored at -20 ℃.By using the urinary RBP commodity kits,the latex enhanced immunoturbidimetry was adopted to detect urinary RBP,the intra-batch and inter-batch precisions were detected respectively.Then the high and low values of self-prepared controls were detected once per day for consecutive 5 months.The data were processed by using the SPSS13.0 software.Then the performance of self-prepared urinary RBP quality control was evaluated.Results The intra-batch imprecision of 2 levels of urinary RBP controls was less than 5% and the inter-batch imprecision was less than 6%;the stable period by storage at -20 ℃ was at least 5 months,the imprecision had no statistical difference within 5 months(P >0.05).Conclu-sion The high and low levels of self-prepared urinary RBP quality controls can meet the operating requirements of internal quality controls.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA