Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Artículo en Inglés | IMSEAR | ID: sea-158234

RESUMEN

Context: Discrepancies at the abutment/crown interface can affect the longevity of zirconia restorations. Aim: The aim was to evaluate the marginal and internal discrepancies (MD and ID) of zirconia copings manufactured by two milling systems with different finish lines. Materials and Methods: Three aluminum‑master‑dies (h = 5.5 mm; Ø =7.5 mm; 6°), with different finish lines (large chamfer [LC]; tilted chamfer [TC]; rounded shoulder [RS]) were fabricated. Twenty impressions were made from each master die and poured. Sixty zirconia copings were manufactured and divided according to the factors “finish line” and “milling system” (n = 10): CADLC = Computer‑aided design/computer‑aided manufacturing (CAD/ CAM) + LC; CADTC = CAD/CAM + TC; CADRS = CAD/CAM + RS; MADLC = manually aided design/manually aided manufacturing (MAD/MAM) + LC; MADTC = MAD/MAM + TC; and MADRS = MAD/MAM + RS. For MD analysis, each coping was fixed, and the distance between the external edges of the coping and the edge of the cervical preparation was measured (50 points). Using the same copings, the ID of each coping was evaluated, by the replica technique, at 12 points equally distributed among the regions (n = 10): Ray (R), axial (A), and occlusal (Occl). The measurements were performed by optical microscopy (×250). The data (μm) were subjected to parametric and non‑parametric statistical analyses. Results: For the MAD/MAM system, the “finish line” (P = 0.0001) affected significantly the MD median values (μm): LC = 251.80a, RS = 68.40a and TC = 8.10b (Dunn’s test). For the CAD/CAM system, the median MD values (μm) were not affected by the factor “finish line” (P = 0.4037): LC = 0.82a, RS = 0.52a, and TC = 0.89a. For the ID, it was observed interaction between the finish line types and the region (P = 0.0001) and between region and milling system (P = 0.0031) (RM‑ANOVA). Conclusions: The CAD/CAM system presented lower MD values, regardless the finish line. However, the MAD/MAM system showed ID values smaller than those of CAD/CAM.


Asunto(s)
Adaptación Marginal Dental , Diseño de Prótesis Dental/métodos , Propiedades de Superficie , Circonio
2.
In. Rodrigues, Daltan Matos. Manual de prótese sobre implantes. Natal, Artes Medicas, 2007. p.19-30, ilus. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-453500
3.
In. Rodrigues, Daltan Matos. Manual de prótese sobre implantes. Natal, Artes Medicas, 2007. p.31-41, ilus, tab. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-453501
4.
In. Rodrigues, Daltan Matos. Manual de prótese sobre implantes. Natal, Artes Medicas, 2007. p.43-66, ilus, tab. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-453502
5.
In. Rodrigues, Daltan Matos. Manual de prótese sobre implantes. Natal, Artes Medicas, 2007. p.67-81, ilus. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-453503
6.
In. Rodrigues, Daltan Matos. Manual de prótese sobre implantes. Natal, Artes Medicas, 2007. p.83-112, ilus, tab. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-453504
7.
In. Rodrigues, Daltan Matos. Manual de prótese sobre implantes. Natal, Artes Medicas, 2007. p.113-136, ilus. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-453505
8.
In. Rodrigues, Daltan Matos. Manual de prótese sobre implantes. Natal, Artes Medicas, 2007. p.137-154, ilus, tab. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-453506
9.
In. Rodrigues, Daltan Matos. Manual de prótese sobre implantes. Natal, Artes Medicas, 2007. p.155-181, ilus, tab. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-453507
10.
In. Rodrigues, Daltan Matos. Manual de prótese sobre implantes. Natal, Artes Medicas, 2007. p.183-202, ilus, tab. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-453508
11.
J. bras. ortodon. ortop. facial ; 6(31): 83-86, jan.-fev. 2001. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-336377

RESUMEN

Säo abordados os fatores de relevância na determinaçäo do registro da relaçäo cêntrica, tais como: posiçäo e relaxamento do paciente, técnica de manipulaçäo e material para registro. Seräo demonstradas as associaçöes entre técnicas e materiais que preencham os requisitos para um registro preciso da relaçäo cêntrica


Asunto(s)
Humanos , Relación Céntrica , Registro de la Relación Maxilomandibular/métodos
12.
JBC j. bras. clin. estet. odontol ; 4(19): 22-24, jan.-fev. 2000.
Artículo en Portugués | LILACS, BBO | ID: lil-427999

RESUMEN

Os preparos mudaram substancialmente desde a introdução da cimentação adesiva. As mudanças surgidas nos preparos extra e intra-coronários são relatadas enfatizando o adequamento sofrido em virtude das características dos materiais restauradores utilizados na cimentação adesiva


Asunto(s)
Incrustaciones , Preparación Protodóncica del Diente , Materiales Dentales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA