Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Braz. oral res. (Online) ; 32: e006, 2018. tab
Artículo en Inglés | LILACS | ID: biblio-889499

RESUMEN

Abstract The purpose of this cross-sectional study was to investigate the effect of different forms of periodontal diseases on Oral Health-Related Quality of Life (OHRQoL). Fifty-two patients with Aggressive Periodontitis (AP) or Chronic Periodontitis (CP) were included: nine patients with Localized Aggressive Periodontitis (LAP), thirty-three patients with Generalized Aggressive Periodontitis (GAP) and ten patients with Generalized Chronic Periodontitis (GCP). Oral Health Impact Profile questionnaires (OHIP-14) were distributed after a clinical examination that measured the following periodontal parameters: tooth loss, bleeding on probing (BoP), probing depth (PD), gingival recession (REC) and clinical attachment level (CAL). The global OHIP-14 score means were 10.6 for LAP, 16.5 for GAP, and 17.5 for GCP. A statistically significant difference (p < 0.01) was observed between the LAP group and the other two groups. There was significantly less bleeding and recession in the LAP group than in the patients with the generalized forms of periodontitis. LAP, GAP and GCP have an impact on patient quality of life when measured using the OHIP-14. Patients with GAP and GCP had poorer OHRQoL than LAP patients.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Adulto Joven , Periodontitis Agresiva/fisiopatología , Salud Bucal/estadística & datos numéricos , Calidad de Vida , Factores de Edad , Análisis de Varianza , Periodontitis Crónica/fisiopatología , Estudios Transversales , Recesión Gingival/fisiopatología , Pérdida de la Inserción Periodontal/fisiopatología , Índice Periodontal , Valores de Referencia , Índice de Severidad de la Enfermedad , Factores Sexuales , Perfil de Impacto de Enfermedad , Estadísticas no Paramétricas , Pérdida de Diente/fisiopatología
2.
Braz. oral res. (Online) ; 32: e56, 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-952163

RESUMEN

Abstract Given the growing trend towards medical indications for continuous use of anticoagulants, the number of patients on these medications continues to rise. The management of patients on oral anticoagulants requiring oral surgical procedures has aroused much controversy. Changes in an anticoagulation regimen are associated with an increased risk of thromboembolism. However, it seems logical and advantageous for the patients' health if surgery could be performed without any change to the anticoagulation therapy. In dentistry, high-power lasers have been poorly explored in this field. The hemostatic properties of high-power lasers could be helpful during oral soft tissue surgeries in anticoagulated patients. The aim of this study was to compare bleeding time in anticoagulated rats after lingual frenectomy performed with a scalpel or diode laser with bleeding time in healthy animals. Twenty-four male Wistar rats were assigned to four groups (n = 6): (CS) Control-Scalpel Surgery; (AS) Anticoagulated-Scalpel Surgery; (CL) Control-Laser (diode laser 810 nm/1.5 W) Surgery; and (AL) Anticoagulated-Laser Surgery (diode laser 810 nm/1.5 W). Warfarin administration was used to induce anticoagulation. Blood was blotted every 30 seconds with filter paper until bleeding stopped to verify bleeding time. Two blinded researchers performed the surgeries and collected the bleeding time data. Diode laser surgery led to complete hemostasis in rats during and after lingual frenectomy. Zero bleeding was assessed during surgeries and after diode laser surgeries in anticoagulated rats. Laser-induced hemostasis offered an alternative solution to the controversial issue of intraoperative and postoperative bleeding control in patients on anticoagulation therapy.


Asunto(s)
Animales , Masculino , Coagulación Sanguínea/efectos de la radiación , Coagulación con Láser/métodos , Hemorragia Posoperatoria/prevención & control , Láseres de Semiconductores/uso terapéutico , Frenillo Lingual/cirugía , Tromboembolia , Warfarina/uso terapéutico , Tiempo de Sangría , Método Doble Ciego , Reproducibilidad de los Resultados , Factores de Riesgo , Resultado del Tratamiento , Ratas Wistar , Anticoagulantes/uso terapéutico
3.
Braz. oral res ; 25(2): 116-121, Mar.-Apr. 2011. ilus, tab
Artículo en Inglés | LILACS | ID: lil-583848

RESUMEN

This study evaluated fracture torque by torsion, in relation to the length and diameter of orthodontic mini-implants, to demonstrate their viability for clinical and experimental use based on the torque recommended by the manufacturers. The fractures at the moment of insertion, whose incidence in the literature is around 4 percent, are principally due to excessive force and the inability of the implant to resist rotational forces. Thirty orthodontic mini-implants of three commercial brands available in Brazil (Neodent 1.6 x 9 mm, Dentoflex 1.6 x 9 mm and Kopp 1.6 x 9 mm) were attached to a device made specifically for this research, leaving the mini-implants with sufficient stability. The miniimplants were submitted to torsion torque, using a digital torque wrench, until their breaking point. The values obtained with the test were submitted to analysis of variance and the Tukey test. The mean values of mini-implant ruptures were 26 N.cm for group A (Dentoflex), 25.4 N. cm for group B (Kopp) and 32.8 N.cm for group C (Neodent). From the Tukey test we could observe that the relationships between the means of the Dentoflex and Neodent groups, and between the Kopp and Neodent groups, were significant. Between the Dentoflex and Kopp groups, significance was nonexistent. All the values found in our research for fracture torque were higher than the limits recommended by the manufacturers for clinical use in orthodontics. The highest values were found in the Neodent group.


Asunto(s)
Implantes Dentales , Métodos de Anclaje en Ortodoncia/instrumentación , Torque , Titanio/química , Análisis de Varianza , Tornillos Óseos , Análisis del Estrés Dental , Ensayo de Materiales , Diseño de Aparato Ortodóncico , Métodos de Anclaje en Ortodoncia/métodos , Estrés Mecánico
4.
Odonto (Säo Bernardo do Campo) ; 16(32): 90-97, jul.-dez. 2008.
Artículo en Portugués | LILACS, BBO | ID: lil-542933

RESUMEN

O objetivo desta revisão é auxiliar o cirurgião dentista na indicação e aplicação da antibioticoterapia no abscesso periapical agudo, em casos de alergia e infecções resistentes, obtendo o sucesso clínico desejado e evitando a resistência bacteriana.


The aim of this study is assist the dentists on indication and application of antibiotic therapy on acute apical periodontits, in allergies cases and resistants infections, obtaining a wished clinical success and avoiding acquired bacterin resistance.


Asunto(s)
Absceso Periapical/etiología , Absceso Periapical/terapia , Antibacterianos/administración & dosificación , Farmacorresistencia Bacteriana , Periodontitis Periapical , Amoxicilina , Metronidazol , Penicilinas
5.
RPG rev. pos-grad ; 14(1): 7-12, jan.-mar. 2007.
Artículo en Portugués | LILACS, BBO | ID: lil-529439

RESUMEN

A significância clínica dos achados eletrocardiográficos para pacientes sem histórico de doença cardiovascular é pequeno ou inexistente; porém, em pacientes com doenças cardiovasculares poderia justificar o uso de monitoração contínua, incluindo uso de eletrocardiograma, além de terapêutica comportamental ou medicamentosa para certos procedimentos odontológicos com níveis de estresse moderado a elevado. Este estudo teve como objetivo a avaliação das alterações eletrocardiográficas em cirurgias para a colocação de implantes dentários sob anestesia local com cloridrato de lidocaína 2% associado a epinefrina e uso de pré-medicação ansiolítica, com 15 mg de midazolam. O estudo foi realizado em 15 pacientes ASA I, com necessidade de implantes dentários, bilaterais em mandíbula. O estudo foi comparativo com placebo administrado aleatoriamente, duplo-cego uma hora antes do procedimento. O eletrocardiograma registrou 12 derivações estáticas a cada 2 minutos e o registro da derivação D2 de maneira contínua, avaliando a presença de arritmias durante o experimento. Não foram encontradas diferenças significantes entre os grupos estudados. Foram observadas arritmias em 53,3% dos pacientes. As arritmias encontradas foram a taquicardia e a bradicardia sinusal, as extra-sístoles supraventriculares, ventriculares e a extra-sístole atrial bloqueada, em ambos os grupos de maneira semelhante, com maior incidência nas fases início e perfuração. As arritmias encontradas foram consideradas de baixo risco para pacientes sem comprometimento sistêmico. Concluiu-se que o uso de 15 mg de midazolam não apresentou diferença quando comparado ao placebo. As arritmias mais freqüentes foram as extra-sístoles e as taquicardias sinusais.


Asunto(s)
Ansiolíticos/uso terapéutico , Sedación Consciente , Implantes Dentales , Arritmia Sinusal , Electrocardiografía , Estrés Fisiológico
6.
São Paulo; s.n; 2006. 148 p. ilus, tab, graf. (BR).
Tesis en Portugués | LILACS, BBO | ID: lil-453525

RESUMEN

A significância clínica dos achados eletrocardiográficos para pacientes sem histórico de doença cardiovascular é pequeno ou inexistente, porém em pacientes com doenças cardiovasculares poderia justificar o uso de monitoração contínua, incluindo o uso de eletrocardiograma além de terapêutica comportamental ou medicamentosa para certos procedimentos odontológicos com níveis de estresse moderado a elevado. Este estudo teve como objetivo a avaliação das alterações eletrocardiográficas em cirurgias para a colocação de implantes dentários sob anestesia local com cloridrato de lidocaína 2 por cento associado a epinefrina, com uso de pré-medicação ansiolítica com 15mg de midazolam. O estudo foi realizado em 15 pacientes ASA I, com necessidade de implantes dentários, bilaterais em mandíbula. O estudo foi comparativo com placebo administrado aleatoriamente, duplo cego 1 hora antes ao procedimento. O eletrocardiograma registrou 12 derivações estáticas a cada 2 minuto e o registro da derivação D2 de maneira contínua, avaliando o comportamento morfológico da onda eletrocardiográfica e a presença de arritmias durante o experimento. Não foram encontradas diferenças significantes entre os grupos estudados. Quando comparamos o comportamento dos parâmetros eletrocardiográficos durante as fases do procedimento, observamos diferenças estatísticas (p<0,01) para a freqüência cardíaca, amplitude da onda P e duração dos intervalos RR e QTc para o grupo com sedação. Foram observados arritmias em 53,3 por cento dos pacientes. As arritmias encontradas foram a taquicardia e a bradicardia sinusal, as extrasístoles supraventriculares, ventriculares e extrasístole atrial bloqueada, em ambos os grupos de maneira semelhante, com maior incidência nas fases início e ferfuração. As arritmias encontradas foram consideradas de baixo risco para pacientes sem comprometimento sistêmico. Conclui-se que o uso de 15mg de midazolam não apresentou diferença quando comparado ao placebo. A fase incisão apr...


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anestesia Local , Ansiolíticos , Arritmias Cardíacas , Electrocardiografía , Hipnóticos y Sedantes , Implantes Dentales
7.
RBP Rev. bras. implantodont. protese implant ; 10(37): 41-46, jan.-mar. 2003. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-366049

RESUMEN

Foram selecionados 20 pacientes normotensos com indicação de colocação de um implante na arcada inferior posterior, utilizando como anestésico local o cloridrato de mepivacaína 2 por cento associado a adrenalina 1:100.000 (Scandicaine). Durante o experimento, foram monitoradas as pressões arteriais sitólica e diastólica (PAS e PAD) e a freqüência cardíaca (FC), através dos métodos oscilométrico e fotopletismográfico pelo monitor não-invasivo SCHOLLAR II (Criticare, Inc.). Os valores médios foram registrados a cada minuto e de forma contínua durante as sete etapas do experimento, da seguinte forma: fase 0 - período basal; fase 1 - final da anestesia local; fase 2 - final do retalho mucoperiostal; fase 3 - final da perfuração com a broca-guia; fase 4 - final da colocação do implante; fase 5 - final da sutura; fase 6 - 20 minutos após o final da sutura. De acordo com o teste ANOVA, os resultados encontrados mostraram alterações estatisticamente significantes na dinâmica cardiovascular, ao nível de 5 por cento, na PAS, PAD e FC quando comparamos a fase 0 - período basal - com todas as demais fases. Números mais expressivos ocorreram no intervalo entre a fase 2 e a fase 5, correspondentes ao início e término do procedimento cirúrgico.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Presión Arterial , Sistema Cardiovascular , Frecuencia Cardíaca , Implantes Dentales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA