Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Journal of Biomedical Engineering ; (6): 1009-1012, 2015.
Artículo en Chino | WPRIM | ID: wpr-359530

RESUMEN

In order to help a surgeon to determine a proper canal filing cutting path in a hip replacement operation conveniently, this paper presents a kind of probe with combined structure. Firstly, the doctor can use this kind of combined probe to choose canal filing cutting path. Then, the doctor can use computer to guide the surgeon to file femoral cavity along the selected canal filing cutting path. Through hip replacement corpse experiments, filing effects and used time of using combined probe group and separate control group were analyzed. The experiment results showed that the methods introduced in this paper could lower the difficulty of hip replacement operations, improve the implantation of hip stem prostheses further, and reduce the incidence of surgical complications.


Asunto(s)
Humanos , Artroplastia de Reemplazo de Cadera , Fémur , Prótesis de Cadera , Cirugía Asistida por Computador
2.
Journal of Biomedical Engineering ; (6): 1256-1258, 2005.
Artículo en Chino | WPRIM | ID: wpr-309907

RESUMEN

In a hip replacement case when a standard hip stem is chosen, it is rough to select hip stems before operation, thus some stand-up standard hip stems should be prepared. The operation time is usually prolonged. In order to solve this problem, this paper presents a method to automatically select optimal standard hip stems by computers. Femoral anatomical data of a patient are acquired from X-ray films. Based on these anatomical data and a database of average cross-sections in proximal femurs, proximal femur of the patient can be reconstructed. This proximal femur model makes it possible to optimally select a standard hip stem. Theory analyses indicate that the method, presented in this paper, is practicable.


Asunto(s)
Humanos , Artroplastia de Reemplazo de Cadera , Diseño Asistido por Computadora , Articulación de la Cadera , Diagnóstico por Imagen , Cirugía General , Prótesis de Cadera , Estándares de Referencia , Radiografía
3.
Journal of Biomedical Engineering ; (6): 666-669, 2004.
Artículo en Chino | WPRIM | ID: wpr-342639

RESUMEN

A novel method for the design of hip joint prostheses based on X-ray films is introduced. Only arcs and straight-lines form figures of hip joint prostheses. Because geometrical tolerances of manufacturing hip joint prostheses matching section are usually not strict, hip joint prostheses can be manufactured without CNC machine tool. Three hip joint prostheses for three different femurs were designed through a program which was developed by the present authors. Approximate marrow cavities of these femurs were simulated according to a standard database about femur. These models of femur marrow cavities were used to verify the hip joint prostheses designed. These hip joint prostheses designed were manufactured and implanted into femurs respectively. Experimental results indicate that the novel method for the design of hip joint prostheses is practicable.


Asunto(s)
Humanos , Diseño Asistido por Computadora , Articulación de la Cadera , Diagnóstico por Imagen , Prótesis de Cadera , Diseño de Prótesis , Métodos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA